HomeMy WebLinkAbout1994 Mosby - Lake Augmentation StudyMOSBY AND ASSOCIATES, INC.
cl Ns"11I,Jj E 16.r1FCF5
January 28, 1994
2455 14TH AVENUE
P.O. BOX 6368
VERO BEACH. FLORIDA 32961
407-569-0035
Mr. Dan Eckis, P.E.
City of Sebastian
1225 Main Street
Sebastian, Florida 32958
Subject: Sebastian Golf Course -Lake Augmentation Study
Sebastian, Florida
Engineer's Project No. 94-137
Dear Mr. Eckis:
At your request, we are hereby submitting our proposal to provide
professional engineering services for the above subject project.
Our breakdown scope of work would include the following:
1. Project coordination with the City of Sebastian.
2. Project coordination with the St. John's River Water
Management District.
3. On-site review of the existing stormwater tracts within
Drainage Basin 5 as noted on the drawing.
4. Preparation of an updated sketch of the area of study of
Basin 5 incorporating the topographic information to be
provided by the City of Sebastian.
5. Provide stormwater calculations as required by the St.
John's River Water Management District to be utilized in
the computive use permit renewal.
6. Final submittal and coordination during the review process.
We propose to provide the herein described services for a total
fee of $1,400.00, excluding direct costs.
Mr. Dan Eckis
January 28, 1994
Page 2
If at any time during the evaluation and design of the herein
stated proposed services it becomes apparent that the described
scope of work changes, we will immediately notify you prior to
making such changes. Such changes will be considered additional
services and will be billed at the following hourly rates:
Sr. Engineering:
$70.00
Per
Hour
Jr. Engineering:
$55.00
Per
Hour
Technician:
$50.00
Per
Hour
Jr. Technician:
$45.00
Per
Hour
Administrative:
$25.00
Per
Hour
Expenses for work required which is not covered in the herein
described items will be billed as direct costs without mark-up.
Direct costs would include such items as printing, permit fees,
long distance telephone calls and mileage reimbursement at $0.25
per mile.
Invoices for our services will be billed on a monthly basis with
payment due upon your receipt of the invoice. A service charge
of 1-1/2% per month will be billed for late payments.
We are available to begin the work described herein upon our
receipt of your written acceptance of this proposal/contract.
Should you require further information or clarification, please
call.
Very t ly y r ,
MOSB & C C. WIT
R dy L. y, P. .
RIM:sdp
Accepted this day of 1994.
Signature Witness
MOSBY AND ASSOCIATES, INC.
10�Sl� ,,,..
2455 14TH AVENUE
P.O. BOX 6368
VERO BEACH. FLORIDA 32961
407-569-0035
February 14, 1994
Mr. Dan Eckis, P.E.
City of Sebastian
1225 Main Street
Sebastian, Florida 32958
Subject: Sebastian Golf Course Lake Augmentation
Sebastian, Florida
Engineer's Project No. 94-137
Dear Mr. Eckis:
Attached are calculations which simulate a 25 year, 24 hour storm
(P=9.2511). Based on our discussions and a site visit, we assumed
a maximum tolerable 25 year stage of approximately 17.0 (one foot
above the existing outfall pipe invert). Beyond this stage, we
feel the golf course will sustain significant adverse impacts due
to flooding.
Using the data provided, there are three apparent drainage basins
which ultimately discharge off-site. These basins are broken
down as follows:
Basin A (Lake "A")
Total drainage area = 31.7 Acres
Paved (Runway area) = 3.4 Acres
Lake Area (@15.5) = 2.9 Acres
Open Space = 25.4 Acres
CN = .8 (80) + .2(98) = 83.6
Basin B (Lake "B")
Total
Drainage Area =
9.2
Acres
Lake
Area (@15.5) =
1.9
Acres
Open
Space =
7.3
Acres
CN = .79 (80) + .21 (98) = 83.4
Mr.'Dan Eckis, P.E.
February 14, 1994
Page 2
Basin D (Lake "D")
Total Drainage Area = 41.3 Acres
Lake Area (@16.5) = 2.2 Acres
Open Space = 39.1 Acres
CN = .95(80) + .05(98) = 80.9
The purpose of the calculations is to determine the highest on-
site storage stage allowable for augmentation with wells. Based
on the flood routings, elevation 15.5 is the maximum stage which
affords the site with reasonable flood protection, therefore, we
recommend no augmentation above that stage.
The flood routings include a drop control structure to be incor-
porated in place of the existing outfall pipe. The purpose of
the control structure is to provide a positive bleed down mecha-
nism in order to assure the required storage is available within
a reasonable recovery period. A secondary benefit of the struc-
ture is it's water quality detention characteristics.
Once you have had a chance to review the enclosed, please contact
this office to discuss. Thank you for the opportunity to help
you on this project.
ery_tr.4y yours,
Steve `Cooper, P.E.
Ste: sap —1 N
enc.
Advanced Interconnected Channel & Pond
Routing (adICPR Ver 1.40)
Copyright
1985, Streamline Technologies,
Inc.
25 YEAR STORM ANALYSIS
2/11/54
BASIN NAME
LAKEA
LAKED
LAKED
NODE NAME
ONSITEA
ONSITEB
ONSITED
TIME INCREMENT (min)
5.00
5.00
5.00
RAINFALL FILE
SCSII-24
SCSII-24
SCSII-24
RAIN AMOUNT (in)
5.25
5.25
9.25
STORM DURATION (hrs)
24.00
24.00
:24.00
AREA (ac)
31.70
9.20
41.30
CURVE NUMBER
83.60
83.40
80.90
DCIA (%)
.00
.00
.00
TC (mins)
30.00
15.00
20.00
LAG TIME (hrs)
.00
.00
.00
BASIN STATUS
ONSITE
ONSITE
ONSITE
BASIN DMX (i=fs) TMX
(hrs) VOL
(in) NOTES
LAKEA 140.50
12.00
7.25 LAKE
"A" DRAINAGE
BASIN
LAKEB 57.45
11.92
7.22 LAKE
"B" DRAINAGE
BASIN
LAKED 217.55
12.0
6.91 LAKE
"D" DRAINAGE
BASIN
Advanced
Interconnected
Channel
& Pond
Pouting (adICPR Ver
1.40)
Copyright 1989,
Streamline
Technologies,
Inc.
25 YEAR STORM
ANALYSIS
2/11/94
NODE NODE
INI STAGE X
-COOK
Y -COOK
LENGTH
STACIE
AR/TM/STR
NAME TYPE
(ft)
(ft)
---------
(ft)
(ft)
---------
(ft)
---------
(ac/hr/af)
---------
-------- ----
ONSITEA AREA
------------------
15.500
.000
.000
.000
15.500
.000
15.500
2.900
16.500
6.000
20.000
31.700
OFFSITE TIME
12.000
.000
.000
.000
12.000
.000
14.000
12.000
14.000
24.000
ONSITED AREA
15.500
.000
.000
.000
15.500
.000
15.500
1.900
16.500
3.000
20.000
9.200
ONS I TED AREA
16.500
.000
. 000
.000
16.500
.000
i00
16.500
2.200
17.500
4.000
20.000
41.000
Advanced Interconnected Channel & Pond Routing (adICPR Ver 1.40)
Copyright 1989, Streamline Technologies, Inc.
25 YEAR STORM ANALYSIS
2/11/94
:REACH NAME RC3
FROM NODE ONSITEA
TO NODE OFFSITE
REACH TYPE DROP STRUCTURE w/ C:IRC:. CULVERT
FLOW DIRECTION : POSITIVE AND NEGATIVE FLOWS ALLOWED
TURBO SWITCH OFF
CULVERT DATA
SPAN
(in):
24.000
RISE
(in):
24.000
LENGTH (ft),
100.000
U/S INVERT
(ft7:
9.000 DIS
INVERT
(ft):
9.000
MANNING N:
.024
ENTRNC
LOSS:
.500 #
OF' CULVERTS:
1.000
POSITION A
:
RECTANGULAR
RISER
SLOT
CREST EL.
(ft):
15.500 CREST LN.
(ft):
.500
OPENING (ft):
999.000
WEIR
COEF.:
3.200
GATE
COEF.:
.600
NUMBER OF ELEM.:
1.000
P'OSIT'ION B
:
RECTANGULAR
RISER
SLOT
CREST EL.
(ft):
16.000 CREST LN.
(ft):
10.200
OPENING (ft):
999.000
WEIR.
COEF.:
2.600
GATE
COEF.:
.600
NUMBER OF ELEM.:
1.000
NOTE: OUTFALL STRUCTURE — FLASHBOARD RIS
Advanc=ed Interconnected Channel & Pond Routing (adIC:PR, Ver 1.40)
Copyright 1589, Streamline Technologies, Inc.
25 YEAR. STORM ANALYSIS
2/11/9#
>)>REAC:H NAME : RCI
FROM NODE : ONSITED
TO NODE : ONSITEA
REACH TYPE : C:ULVERT, CIRCULAR w/ ROADWAY
FLOW DIRECTION : POSITIVE AND NEGATIVE FLOWS ALLOWED
TURBO SWITCH : OFF
CULVERT DATA
SPAN (in): 24.00o RISE (in): 24.000
U/S INVERT (ft): 16.500 D/S INVERT (ft): 16.500
ENTRNC: LOSS: .500 # OF CULVERTS: 1.000
POSITION A : NOT USED
POSITION B : NOT USED
NOTE: CULVERT CONN LAKE D TO LAKE A
>REACH NAME RC2
FROM NODE ONSITEB
TO NODE ONSITEA
REACH TYPE CULVERT, CIRCULAR w/ ROADWAY
FLOW DIRECTION POSITIVE AND NEGATIVE FLOWS ALLOWED
TURBO SWITCH OFF
CULVERT DATA
SPAN (in): 12.000 RISE (in): 12.000
UIS INVERT (ft): 12.000 D/S INVERT (ft): 12.000
ENTRNC LOSS: .500 # OF CULVERTS: 1.000
POSITION A : NOT USED
POSITION B : NOT USED
NOTE: CULVERT CONN LAKE B TO LAKE A
LENGTH (ft); 40.000
MANNING N: .024
LENGTH (ft): 300.000
MANNING N: .024
Advanced Interconnected Channel & Pond Routing (adlC:PR Ver 1.40)
Copyright 1.389, Streamline Technologies, Inc.
25 YEAR STORM ANALYSIS
2/11/94
REACH SUMMARY
INDEX RCHNAME FRMNODE TONODE REACH TYPE
------------------- ------ -------------------------------
1 RCI ONSITED DNSITEA CULVERT, CIRCULAR w/ ROADWAY
2 RC2 ONSITEB ONSITEA CULVERT, CIRCULAR w/ ROADWAY
3 RC:3 DNSITEA OFFSITE DROP STRUCTURE w/ CIRC. CULVERT
Advanced Interconnected Channel & Pond RoUting (adICPR Ver 1.40)
Copyright 1989, Streamline Technologies, Inc.
25 YEAR STORM ANALYSIS
2/11/94
CONTROL PARAMETERS
------------------
START TIME: .00
END TIME: 24.00
TO TIME SIMULATION INC PRINT INC
(hours) (see=s) (mins)
24.00 150.00 60.00
RUNOFF HYDROGRAPH FILE: DEFAULT
OFFSITE HYDROGRAPH FILE: DEFAULT
BOUNDARY DATABASE FILE: NONE
NOTE:
Advanced
Interconnected Channel & Fond
Routing (ad1CPR Ver
1.40)
Copyright
1985, Streamline Technologies,
Inc.
25 YEAR
STORM ANALYSIS
2/11/54
NODAL MAXIMUM CONDITIONS
-------------------------------
REPORT
I<:-------
INFLOW -------%1
NODE
STAGE
VOLUME RUNOFF
OFFSITE
OTHER
OUTFLOW
ID
(ft)
(af) (cfs)
--------
(cfs)
----------------
(cfs)
(cfs)
--------
--------
ONSITEA
--------
16.93
--------
1.63 140.50
.00
7.44
17.27
OFFSITE
14.00
16.96 .0o
.00
17.27
.00
ONSITEB
17.00
5.53 56.18
.00
.00
.54
ONSITED
18.14
17.69 217.55
.00
.00
7.14