HomeMy WebLinkAbout1992 PSI Pumping SystemI�IYSTENGTIC DIVF SERVICES D IITIECHONC. November 17, 1992 Mr. Chris McCarthy Sebastian Municipal Golf Club 100 East Airport Road Sebastian, FL 32958 SUBJECT: PUMPING SYSTEM SPECIFICATIONS FOR SEBASTIAN MUNICIPAL GOLF CLUB Dear Chris: Thank you for the opportunity to provide the following specifications for a PSI pre -fabricated, skid -mounted pumping system. As discussed, this represents a condensed version of the more formal specifications previously submitted. Nevertheless, it should provide you sufficient technical information to meet your needs. Please review the enclosed Company brochure, which details our expanded service and support capabilities. I know you'll be pleased with our customer commitments, too. Let us know if you have questions or if we can assist you in any way. Sincerely, #ohA. Magi era O R }� \ CI(� p (Z I N Customer Service R esentative PM-SlDrc&)T JAM/jkb cc: Alex Elia P.O. BOX 1525 • ONECO, FL 34264-1525 • PH. (813) 755-4589 • 1-800-624-8264 PUMPING SYSTEM Pumping system shall be a completely skid -mounted unit, built by a single pumping system manufacturer, with all equipment, controls, valves and attached hardware a part of the skidded assembly. Pumps, electric motors, hydraulic and electric control equipment, and all equipment pertinent to and included under pumps, motors and controls shall conform to the attached technical specifications. Pumping system manufacturer shall supply equipment of his own manufacture and assembly for all equipment listed above and for all other equipment furnished by him. The manufacturer shall supply a complete set of installation drawings, instructions, operating instructions, and service manuals for all equipment furnished by him. Pumping system shall be a Variable Frequency Drive (VFD), pre- fabricated type with a capacity of 1000 GPM at 125 psi. Station shall be a PSI Model No. CWTP-1000-3-1800-VFD, or approved equal. Station shall consist of a 3 HP, 3600 RPM submersible pressure maintenance pump, and two (2) 50 HP, 1800 RPM vertical turbine main pumps. Standard features of the pumping station shall include the following: 50 HP, 1336VT Allen-Bradley 98% efficient PWM drive, no equal. UL listed, NEMA 4 rated control panel, thermal insulated, leg mounted, with non-resettable hour meters. All indicating lights, reset buttons, selector switches and hour meters shall be mounted in enclosure door. 3. PLC, analog controls with door -mounted, NEMA 4 rated operator interface. 4. 200 AMP branched fused main disconnect. Fabricated steel discharge head with integral air relief valve, high pressure stuffing box and silent wafer -style check valve. Air release valves mounted tangential to flow or on any portion of the discharge piping shall not be acceptable.• 3" CLA-valve brand downstream relief valve piped to wet well. tA�00 r_)1Z1 PAGE -2- 7. Industrial, closed-loop air conditioner and dryer assembly. 8. Drive line reactor. 9. Low Intake water level safety, high discharge pressure safety, low discharge pressure safety, individual phase and low voltage protection for each pump motor, lightning arrestor. 10. Overload shutdown. 11. Pumpwatch software capable of real-time data display, in .graphic form, of: irrigation system pressure, pumping system pressure, system flow, accumulated hours on each pump/motor, which pumps are running, VFD output frequency, any pump system safeties in effect, and status of low pressure override. 12. Flowmeter with NEMA 4 digital display and integral brass sensor (skid mounted). 13. I-beam construction, factory -tested manifolding to 500 psi (hydrostatic). 14. System Isolation Valve. 15. Freight to job site 16. Start-up services and removal of present system 17. Two-year Warranty on Mechanical Components Three-year Warranty on Control Devices Automatic Vertical Turbine Pumping System Technical Specifications Pumping System Model No. CWTP-1000-3-1800-VFD Total Design Criteria: Quantity of Pumps: 3 Pump Check Valve Pump Size Rating psi Drop At No. In psi Pump Capacity 1 2" 400 -- 2 6" 400 1 3 6" 400 1 Relief Valve Size: 3" Pressure Rating: 200 psi Pilot Setting:ginepress 145 Flowsensor Brass , Pressure Rating: 400psi System Isolation Valve: Bq Pressure Rating: 200 psi Service Entrance; 200 Amps, 200,000 Fault Amps, 110 RVA 460 Volts 3 Phase 60 HZ Total Design Flow: 1000 Discharge Pressure: 125 Stationperformance is based on a maximum lift of five feet measured from grade to static water level. Pump Data: Pump Design R.P.M. Eff. At Shutoff Column Shaft Disch. No. G.P.M. Design Head Pipe ID OD Size 1 30 3600 65% 410, 2" .750" 21- "2 2500 1800 81% 340, 6" 1.19" 61- "3 3500 1800 81% 340, 6" 1.19" 6" Pump Overall Length: 9' 6" Minimum water coverage as measured from eye of bottom impeller: 24" Pump Check Valve Pump Size Rating psi Drop At No. In psi Pump Capacity 1 2" 400 -- 2 6" 400 1 3 6" 400 1 Relief Valve Size: 3" Pressure Rating: 200 psi Pilot Setting:ginepress 145 Flowsensor Brass , Pressure Rating: 400psi System Isolation Valve: Bq Pressure Rating: 200 psi Service Entrance; 200 Amps, 200,000 Fault Amps, 110 RVA 460 Volts 3 Phase 60 HZ Motor Starting Code G, Class F Insulation Motor H.P. R.P.M. Service Eff.% Power No. Factor Factor 1 3 3600 2 50 1800 3 50 1800 CFM REQUIREMENTS: Motor No. 1 50 Hp.: Motor No. 2 50 Hp.: VFD AC TOTAL CFM REQUIREMENT: 1.15 818 888 1.15 90.58 878 1.15 90.58 878 320 320 550 SUBMERSIBLE VHS VHS Starting Equipment - U.L. Listed as Industrial Control Assembly: Main Disconnect: 600 Volts, 200 Amps. Motor Disconnect Rating Fuse Fuse AIC NEMA Size O.L. Rating No. HP Volts Amps Amps Rating Starter In Amps 1 3 600 17 6 200,000 OXL 4.8 2 50 600 90 75 200,000 3 VFD 65 3 50 600 90 75 200,000 3XL 65 VFD Controls U.L. Listed as Industrial Control Assembly: Operating Temp: 0 to 40 Degree C (32 to 104 F.) Humidity: 5-958 Non -condensing Minimum Efficiency (full load, base speed) 988 Electrical Data: Line Reactor 75 KVA Input Voltage: 3 phase 480 volt AC Input Frequency: 50/60 HZ. Output voltage: 3 phase 0-480 volt AC Frequency Rating: 1008 continuous drive rating, Intermittent 1118 Drive rating for one minute. Control Circuit Voltage: Internal 90 Volt AC Drive shall be of the Pulse Width Modulated (PWM) type, Current & voltage source drives are unacceptable. LED Indicators shall provide: Power on, Overload, Under Voltage, Over Voltage, "A","B","C" Phase protection, Drive Over Temp, and Output Grounded Diagnostics. 3 Controls U.L. Listed as Industrial Control Assembly: Phase Failure and low voltae shutoff at 908 of motor name plate voltage on all three legs 83g8 on one leg for five seconds. Low discharge pressure shutdown at 105 psi after all pumps are running for 60 seconds continuously. High discharge pressure shutdown at 150 psi after all pumps are running for 60 seconds continuously. Low water level safety shutdown if water falls to within two feet of pump suction. PUMPING SYSTEMS INCORPORATED SPECIFICATIONS FOR AUTOMATIC PUMPING STATION PREPARED FOR: SEBASTIAN MUNICIPAL G. C. THESE SPECIFICATIONS ARE PROVIDED TO DESCRIBE AN ALTERNATE PUMPING SYSTEM WHICH MAY BE AT VARIANCE TO ORIGINAL BID SPECIFICATIONS. IF THE PSI DESIGN IS ACCEPTED, IT SHALL BE BUILT TO THESE SPECIFICATIONS AND PSI SHALL NOT BE LIABLE FOR ANY SUCH DIFFERENCES. PSI MODEL NUMBER: CWTP-1000-3-1800-VFD DESIGN: 1000 GPM @ 125 psi PSI DESIGN AND SPECIFICATIONS: ACCEPTED BY: DATE: TITLE: GENERAL SPECIFICATIONS PURPOSE !A$cK .. 1.0 To provide single -source responsibility for manufacture, warranty, service and personnel training for the pumping system. Pumping system shall conform to these specifications in all respects. 1.1 This pumping system shall lift water from a shallow wet well and automatically deliver it to the turf irrigation system. SCOPE 2.0 Pumping system shall be a completely skid -mounted unit, built by a single pumping systems manufacturer, with all equipment, controls, valves and attached hardware a part of the skidded assembly. All pumps, electric motors, hydraulic and electric control equipment, and all equipment pertinent to and included under pumps, motors and controls shall be furnished by a single pumping systems manufacturer. Pg 1 7228 elm 10/92 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 2.1 The pumping systems manufacturer shall supply equipment of his own manufacture and assembly for all equipment listed above and for all other equipment furnished by him. The manufacturer shall supply a complete set of installation drawings, instructions, operating instructions and service and for all other equipment furnished by him. The manufacturer shall supply a complete set of installation drawings, instructions, operating instructions and service manuals. STATION BASE 3.0 A structurally sound fabricated steel base with provisions for proper mounting and support of all equipment shall be provided. Equipment to be mounted to the structurally sound base shall include but not be limited to: pumps, motors, valves, piping, tank, controls and all other equipmentspecified later in these specifications. All components shall be mounted""'in` a professional, workmanlike manner. 3.1 Skeletal substructure steel bases under fifteen feet in length shall be fabricated from 6" I-beam iron. Bases longer than 15 feet in length shall be fabricated from 8" I-beam iron. Base shall be suitable for mounting and supporting all parts of the pumping system. For wet well application, base shall have a hinged wet well cover plate and base and cover plate shall completely cover wet well or sump., 3.3 The entire unit, with the exception of the control panel and motor, is to be steel grit blasted with # 55 lb grit to a clean 2mm pitted profile surface and primed with a rust inhibitive primer coat to a minimum of 2 mils. Final coat shall be an industrial grade acrylic enamel applied to a minimum dry thickness of 3 mils. PUMPS, VERTICAL TURBINE 4.0 The entire pump assembly including bowl assembly, column, shafting and discharge head shall be of U.S. manufacture. The pumping systems manufacturer shall have a network of service centers which shall have available: 4.1 Stock of pump components for service, repair, and maintenance. 4.2 Pump technicians to handle service, repair, and the handling of warranty procedures. 4.3 The pumping systems manufacturer shall make available a list of the service centers. 4.4 Pump "wet end" components shall be manufactured by .Worthington Pump Co, or equal. 4.5 The pumping system shall include vertical turbine pumps to meet the requirements and engineering specifications listed in the technical section of these specifications. Pg 2 7228 elm 10/92 S�MK 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 4.61 Pump head shall incorporate an integral 1" air release valve to vent air captured in the pump column upon starting. Air release valve shall be mounted on the horizontal plate used for packing box mounting. Air release valves mounted tangential to flow or on any portion of the discharge piping shall not be acceptable. 4.7 A high pressure stuffing box shall seal off leakage around the pump shafting. This box shall be a bypass -type packing container which consist of a lantern ring and at least six rings of packing. Packing shall be compressed around the shaft by an adjustable two-piece gland. The pumped liquid shall lubricate the shaft. The packing shall be of the self-lubricating type, and when properly adjusted no liquid shall be allowed to drain from around the shaft to the exterior of the pump head. 4.9 Discharge column shall conform to ASTM A106 standards. No section shall exceed five (5) feet in length. It shall be sized so that friction loss will not exceed five (5) feet per one hundred (100) feet. Each section shall be subject to a pressure test varying from a minimum of 1900 psi for 4" diameter to a minimum of 1000 psi for 12" diameter. At each column joint a bearing assembly shall be installed. 4.10 Column ends shall be machine -faced to provide a butt fit between column sections to maintain alignment throughout pump column assembly. 4.11 The shaft shall be held in place with a bronze bearing retainer containing a water -lubricated neoprene insert designed for vertical turbine pump service. 4.12 The bowl, suction and discharge connection shall be of close -grained, class 35 cast-iron having a minimum tensile strength of 30,000 psi, free from blow holes, accurately machined and fitted to close dimensions. 4.13 Each pump bowl shall have a wear ring to prevent wear on the bowl. The ring shall be constructed from cast-iron and be replaceable. 4.14 All bowl bearings shall be B1 leaded red brass. 4.15 Suction case bearing shall provide for accurate alignment of all impellers. The bearing shall be a minimum of five (5) shaft diameters in length and shall have a bronze collar immediately above to prevent abrasives from entering the bearing. 4.16 The impeller shall be of B1 leaded red brass, accurately machined, finished and mechanically balanced. Each impeller shall be securely fastened to the impeller shaft with a tapered steel lock collet. Impellers shall be of enclosed type with perihedral seals to provide vertical cylindrical and horizontal surface impeller sealing. This seal shall prevent shaft stretch from affecting pump performance. Adjustment required due to wear shall be accomplished with a shaft adjusting nut located at the top of the motor. Pg 3 7228 elm 10/92 IS'NO10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 4.17 The impeller shaft shall be of stainless steel 410 ANSI alloy of not less than 12% chromium content, having a tensile strength of not less than 100,000 psi. No so-called rustless iron shall be considered. 4.16 The impeller shaft shall be supported by a combination of water lubricated, fluted rubber and bronze bearings. 4.19 The shaft's horsepower rating, machining, and straightness tolerance shall conform to ANSI B58.1/AWWA E101 Standards. 4.20 The headshaft shall be constructed of 416 stainless steel. It shall be of two-piece construction with a coupling between the stuffing box and motor base on all units. Each headshaft is to be supplied with a suitable slinger ring to prevent stuffing box waste from entering the motors' hollowshaft. 4.21 Column shafting shall conform to the same standard as the impeller shaft and shall be coupled with threaded couplings constructed of 416 stainless steel. / 4.22 Each pump shall have a bypass line to pass sufficient amount of water to prevent overheating of pumps at shutoff conditions. Bypass line shall be an integral part of the packing box to maintain a cooling flow over the packing box bearing. Bypass lines mounted on pump discharge head are not acceptable as they do not provide cooling flow to packing box bearing. PUMP CHECK VALVE 5.0 Pump check valves shall be silent check -wafer style supplied on pump discharge. Valve bodies shall be cast from grade 35 cast-iron or better and shall be free from blow holes, sand holes and other impurities. Internals shall be machined bronze disc and stem guide and shall be aligned to allow proper seating and full closure before flow reversal. Seat shall be Buna-N to provide resilient sealing. 5.1 Valves shall be sized to permit full pump capacity to discharge through them without exceeding a pressure drop of 3 psi. Valves shall be of the type manufactured by Empire Specialty Co. Inc. PIPING 7.0 Separate pump discharge piping shall be constructed from ASTM A120, ASTM A53, or API 5L steel pipe. Piping 6" in diameter or smaller shall be constructed from schedule 40 pipe or heavier and piping 8" and larger shall be constructed from schedule 30 pipe or heavier. 7.1 All piping shall be sized so that not exceed 4.8 feet per second and per second. Pg 4 7228 elm 10/92 117s,n10717 HARRY HINES BLVD. the average velocity does at no point exceeds 9.5 feet DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 7.2 All pumps shall discharge into the pressure manifold assembly. Discharge piping connecting the pressure manifold to the isolation valve and isolation valve to the check valve shall be schedule 80 weight. Discharge piping shall be victaulic grooved to provide flexibility, vibration dampening and expansion between the pumps and manifold assembly. In addition, the manifold, related piping and all fittings shall be hydrostatically pressure tested to 500 psi minimum. RELIEF VALVE FOR VARIABLE FREQUENCY DRIVE 16.1 The valve shall be mounted downstream of the pump discharge manifold and its discharge shall be piped back into intake manifold. All related piping shall be mounted within the confines of the steel base. The valve shall be sized to maintain pipeline pressure within 10 psi of stated system pressure with all pumps discharging at full capacity. 16.2 Pressure sustaining pilot shall be sensitive to valve inlet pressure. Pilot shall be normally closed and spring-loaded with a spring tension adjustment. Pilot shall open automatically against the spring valve of the setting. This pilot shall function to maintain a minimum system pressure to prevent irrigation system from operating under a sustained high pressure. 16.3 A wafer -type lug pattern butterfly valve shall be provided at the pressure -relief valve inlet to completely isolate it from the turf irrigation system for maintenance purposes. Valve shall conform to the same specification as the station discharge isolation valve listed elsewhere in these specifications. FLOWMETER I18.0 A digital -type flowmeter shall be supplied as an integral t of the pump station. Flowmeter display shall be a NEMA 4 rated, door -mounted digital display and shall be integral to the operator interface module of the pump station. It shall be \G5 installed in the station discharge piping and shall be installed so as to give optimum accuracy, of reading. Measuring mechanism shall be a synthetic polymer signal generator and shall perform with 98% accuracy. Totalizer reading shall be in gallons and direct -reading indicator shall be supplied, indicating gallons per minute. GAUGES 20 .0 All gauges shall be silicon filled to reduce wear due to vibration. Accuracy shall be 99%. Gauge diameter shall be 3 1/2" minimum. Housing shall be impact -resistant stainless steel and internals shall be stainless steel. Range shall be at least 30% higher than the highest pressure attainable from the pumps at shutoff head conditions. Gauges shall sense true irrigation l system pressure downstream of any filtration devices. Pg 5 7228 elm 10/92 �V0115K V 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 SYSTEM ISOLATION VALVE 21.0 System isolation valve shall be installed on the pumping system discharge to completely isolate the pumping system from the turf irrigation system. Valve shall have one-piece body cast rom meehanite iron. Stem shall be 416 stainless steel. Disc shall be cadmium -plated ductile iron. Stem bushing shall be luberized bronze to prevent stem seizure to body during prolonged periods of non-use. Seat shall be Buna-N elastomer of one piece construction and shall also form the flange sealing caskets. For valves 6" and smaller, handle shall be ten -position locking lever. Valves 8" and larger shall be gear operated. Valves shall be rated at 150 psi bubble -shutoff. LIGHTNING ARRESTOR V22.0 All electrical equipment shall be protected by a secondary lightning arrestor to suppress surges on incoming power. Lightning arrestor shall have a maximum clamping voltage of 1500 VRMS or less with an unlimited power rating. Response time at terminal shall be one (1) microsecond per ten (10) kilovolts. Extreme duty discharge shall be twenty (20) kiloamps on an 8 by 20 microsecond wave shape. Minimum break over voltage shall be 750 VRMS at one (1) kiloamp on an 8 by 20 microsecond waveshape. Jw� \ MAIN DISCONNECT 23.0 A fusible or circuit breaker main disconnect shall be provided to completely isolate the pump station and all its pertinent equipment from incoming power. Main disconnect shall be sized so that it is not loaded beyond 80% of its capacity and so that it provides adequate short circuit protection to all equipment on the pump station. It shall be able to interrupt any fault current it is likely to encounter and shall have an ampinterrupting capacity (AIC) of not less than 125% of the available fault current. Circuit breaker main disconnect may require current -limiting fuses in series with it to provide the necessary AIC. If current -limiting fuses are required they shall be sized so as not to allow any unprotected current value between the maximum AIC of the circuit breaker and the minimum AIC of the current -limiting fuses. MOTOR STARTING EQUIPMENT 25.0 A non -fusible main disconnect shall be provided to completely isolate all controls and motor starting equipment from incoming power. The disconnect shall be sized so that it is not loaded beyond 80% of its capacity. 25.1 All motor starting equipment shall be located in a single NEMA 4 enclosure. Pump motor starters shall be NEMA sized's horsepower -rated contactors with overload relay. Fuses shall supply short circuit protection to the motor and shall not be rated at less than fault current available to the motor. NEMA size, overload rating and maximum fault protection shall be as specified in the attached technical specifications. Pg 6 7228 elm 10/92 25.2 Motor starting equipment shall be U.L. Listed by the pump 9�S station manufacturer as a completed industrial control device, "l with U.L. label attached to the panel of NEMA 4 enclosure. 25.21 Definite contactors, or IEC/NEMA dual -rated contactors N fl shall not be acceptable. Starters shall be of the type manufactured by Allen-Bradley Co., series 500. MOTORS, VERTICAL HOLLOW SHAFT AND HORIZONTAL 27.0 All vertical hollow shaft motors shall have drip -proof enclosure in compliance with NEMA standard MG 1-1.25 or TEFC enclosure in compliance with NEMA standard MG 1-1.26. Motors shall be continuously rated in accordance with NEMA standard MG 1 and shall be NEMA electrical design B with 1.15 minimum service factor. Insulation shall be Class F and have a temperature rise in accordance with NEMA standard MG 1 over a maximum ambient temperature of 104 degrees Fahrenheit (40 degrees Celsius). Vertical hollow shaft motors manufactured by Newman and U.S. C� Motors are acceptable. Horizontal motors manufactured by Baldor, fCentury, U.S. Motors or General Electric are acceptable. 27.1 Motors shall be wound for the starting configuration necessary to be compatible with the starting equipment specified previously. Starter frame and end brackets shall be machined from rigid grey iron castings and the housing in the end brackets for the bearings shall be precision bored to provide correct fit for the bearings. Cast-iron conduit box shall be weatherproof -type with gaskets fitted at all joints and shall be tapped for ease of conduit connection. 27.2 Couplings shall be bolted to the motor so as not to allow any uncoupling or slipping during momentary pump upthrust. 27.3 The thrust bearing shall have ample capacity to carry the weight of all moving parts, plus the hydraulic thrust of the pump impellers, and have sufficient safety factor. This factor shall be based on continuous use f) full years at 24 hours per.0ay operation. SUBMERSIBLE PRESSURE MAINTENANCE PUMP 7�S�T motor shall be of the submersible type. Motor shall be water -lubricated submersible conforming to NEMA standards. It shall have a hermetically -sealed stator. Internal thrust bearing shall be capable of carrying the maximum pump thrust. 27.6 Motors shall be wound for the starting configuration necessary to be compatible with the starting equipment specified previously. 27.7 Couplings shall be bolted to the rotor so as not to allow any uncoupling or slipping during momentary pump upthrust. 27.8 The thrust bearing shall have ample capacity to carry the weight of all moving parts, plus the hydraulic thrust of the pump impellers, and have sufficient safety factor. This factor shall be based on continuous use for five (5) years at 24 hours per day operation. ( Pg 7 7228 elm 10/92 �unnna 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 nc 27.9 The wet end of the pump is to be manufactured by Grundfos 00 Pump Co., model no.25S. CONTROLS 28.0 Control panel shall be housed in NEMA 4 enclosure. Panel shall provide timed sequential pump start up and shutdown and safety features through its pressure sensing, flow sensing and voltage sensing devices. Running -time meters shall display in hours and tenths the total time of each motor. Hour meters shall not be resettable to insure continuous time monitoring. All indicating lights, reset buttons, selector switches and hour meters shall be mounted in enclosure door. 28.1 Power for the controls shall be provided by a control voltage transformer whose sole use shall be for pumping system control. Transformer shall provide 120 volt, single-phase power for pumping system operation. Current -limiting fuses shall protect the primary side of the transformer and shall have 200,000 AIC. Control components shall be protected by a time delay circuit breaker with at least 10,000 AIC. All 120 volt signals issuing from the control panel to operate equipment \�• supplied by others shall be circuit breaker protected, having 10,000 minimum AIC, and a nominal valve substantially less than the transformer secondary fuse to prevent its blowing. All devices shall have pilot lamps to indicate when power is on shall have a pilot lamp for troubleshooting. All 120 volt fuses shall have a pilot lamp in parallel to indicate a blown -fuse condition. 28.2 Control cabinet with controls shall be U.L. Listed as a completed assembly by the pumping system manufacturer, with a \� U.L. label mounted on panel of enclosure. 28.3 All equipment and wiring shall be mounted within an enclosure and labelled for proper identification. All adjustments and maintenance shall be accessible from the front of J the controls enclosure. A complete wiring circuit and legend with all terminals, components and wiring identification shall be �C provided. All control components shall be assembled from_),E,Ie�&,O_.- standard industrial logic components which shall be available from major metropolitan -area vendors. J 28.4 Controls shall be of the microprocessor programmable -type, with an industrial operator interface providing data entry and readout. Operator interface shall be NEMA 4 rated, door -mounted, digital readout to display GPM, psi, flow total, register values !}) and safeties as needed or applicable. Device shall allow access \\' to timers, counters and sequencer data. Programmable controls shall have LED indicators for input, output, battery low and PC run. A status indicator is provided for each I/O. Programmable controls shall be provided for a three (3) year lithium battery backup for CMOS RAM memory. Pg 8 7228 elm 10/92 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 1214) 357-1320 FAX (2141357-5861 28.5 Industrial -grade programmable controller shall be rated to operate at 150 degrees Farenheit and 95% humidity maximum. The program for pump station operation shall be stored in U.V. PROM memory, such that if the programmable controller loses incoming power and there is a fault with the battery backup, the programmable controller cannot lose the program. 28.6 Analog 'input board shall have four (4) receiving channels and have 3 1/2 digit resolution. Board shall be capable of receiving one (1) of four (4) input signals (0-10 VDC, 1-5 VDC, -10-+10 VDC, 4-20 mA) and be field -convertible to accept any one of the supply signals. 28.7 Pressure transducers shall sense true irrigation pressure downstream of any filtration devices that are mounted within the confines of the skidded assembly, and shall feed analog -input board of programmable controller. Transducers shall have a stainless steel diaphragm and an insulated electrode to form a variable capacitance. Transducer shall require a 12 VDC power supply with no greater than a 01 mV ripple response. Transducer shall have a maximum of .02% repeatability accuracy and 5 ms reaction time. No devices mounted external to the PLC rack assembly shall be supplied by the internal 24 VDC power supply of the rack. 28.8 Flowmeter shall provide a digital rate -of -flow indication, totalizer, and analog signal to feed analog board of the programmable controller. Flowmeter shall be field -adjustable to re -calibrate so to meet municipal accuracy requirements. Meter shall be capable of sending one (1) of four (4) output signals (0-10 VDC, 1-5 VDC-10-+10 VDC, 4-20 MA) and be fieldconvertible. Flowmeter shall maintain a 1% repeatability and 98% accuracy. VARIABLE FREQUENCY DRIVE CONTROL 28.9 VFD controls shall convert fixed frequency, 3-phase industrial line power to DC and invert to 3-phase variable frequency/voltage output power for direct application to standard AC induction motors. Standard drive includes power conversion components, logic circuitry, diagnostic displays and LSI circuit used to generate control signals. 28.10 VFD will cancel the valve for maintaining system monitored and converted to utilize these analog signals pump and motor. Pg 9 7228 elm 10/92 10717 HARRY HINES BLVD need for a pressure -reducing control pressure. System pressure shall be analog signals. The drive unit shall for variable speed control of the DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 28.13 VFD unit and accompanying controls shall be housed in a single NEMA 4 enclosure. Enclosure shall include an industrial air conditioner to constantly cool and recirculate the internal enclosure air using a closed-loop design. Recirculation of internal air shall provide a degree of safety from high ambient temperatures, airborne dirt and moisture. Housing shall be 16 gauge steel. Air conditioner shall be designed to operate on 120 volts AC, 60 HZ. single-phase with a minimum of 20,000 hours of continuous operation. 29.13 Pump station manufacturer shall provide a programmable controller override capability in the event of a component failure. The override will allow the pumps to be operated in the manual position. 29.14 All indicator lights mounted on panel door shall be transformer type for long life. Full -voltage lamps shall neither be provided nor acceptable. 29.15 Station shall include a drive isolation transformer. Isolation transformer to be sized to accommodate full voltage of VFD drive. Isolation transformer must be designed to accommodate the electrical and mechanical stresses caused by regenerative current reversals and frequent short circuits inherent to heavy duty cycles required to drive applications. Line reactors are unacceptable as they have no provisions for tapping up or down to provide the preferred 460 vac to drive. 29.16 Station shall include a line reactor to be sized to accommodate the electrical and mechanical stresses caused by regenerative current reversals and frequent short circuits inherent to heavy duty cycles required to drive applications. SAFETY PROTECTION 30.1 System shall include the following safety, logic and sequential circuits: SAFETY, LOW INTAKE WATER UvaS 30.2 Low intake water level supply safety circuit shall shut down pumping system if water supply level drops below acceptable level for pump operation. Circuit shall include adjustable timer set for three (3) seconds to prevent sporadic shutdown in the event of power flicker. Pumping system shall not operate until water supply is up to safe level and circuit has been manually reset. Station shall shut off if water in the wet well falls to within two (2) feet above the bottom of pumps for three (3) seconds. SAFETY, LOW DISCHARGE PRESSURE 30.3 Low discharge pressure safety circuit shall shut down pumping system in the event discharge pressure drops below normal level, indicating a broken main line or over -demand. Indicating light mounted in enclosure door shall signal low discharge Pg 10 7228 elm 10/92 PING VMS. 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 pressure and shall have a red lens. Pumping system shall not operate until safety has been overridden by placing the 'override -normal' switch in the 'override' position. Override shall also allow the pumping system to operate at low pressure for filling lines or transferring water from irrigation reservoir to other locations. SAFETY, HIGH DISCHARGE PRESSURE 30.4 High discharge pressure safety circuit shall shut down pumping system if discharge pressure reaches a predetermined high level. Indicating light mounted in enclosure door shall indicate high pressure and shall have a red lens. Pumping system shall not operate until pressure is reduced and safety has been manual reset. PHASE PROTECTION, INDIVIDUAL MOTOR 30.5 Phase failure and low voltage safety circuitry shall retire any pump that experiences low voltage, phase failure or phase reversal as monitored at the line -side of each pump starter. Each pump motor shall have its individual protective device and time -delay to allow for transient low voltage during motor starting to allow maximum motor protection. This circuit shall provide for individual indicating light and manual reset for each pump. Automatic reset of the phase protection circuit shall not be permitted for safety reasons. PUMP SYSTEM MONITOR (PUMPWATCH) ! 34.3 The manufacturer shall supply the capability to monitor the pumping system from a remote location through the use of a customer -supplied, 100% IBM (PC,XT,AT) compatible personal computer. 34.3 The monitoring system shall have the capability of providing a real-time display, in graphic form, of data including, but not limited to, the following: Irrigation system pressure, pumping system pressure, system flow, accumulated hours on each pump/motor, which pumps are running, Variable Frequency Drive output frequency (if so equipped) , any pump system safeties in effect, status of Low Pressure Override (if so equipped) . 34.4 The monitoring system shall be physically and electronically integrated with the pump system controller but shall not be essential to the automatic operation of the pumping system. 34.5 All software (programming) for the monitoring system shall be directly designed and serviceable by the pump system manufacturer. 34.6 All hardware provided by the pump systems manufacturer for the monitoring system shall be readily available for replacement if the need should arise. This hardware shall be of U.S. manufacture by the U.S.-owned manufacturing facilities. Pg 11 7228 elm 10/92 (S'Ho 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 34.7 The monitoring system shall have the ability to record (log) the following data records: Irrigation system pressure (at the pump system discharge) , system flow, Variable Frequency Drive speed (if so equipped). The monitoring system shall have two types of data logging capabilities. These two data logs shall be separate but simultaneously active. The first type of data log shall record data within a specified time period that can be modified by the user. This data log shall have at least 6600 data points. Each data point shall be defined as consisting of three of the record types described above. The second type of data log shall be of circular and continuing nature. This log shall record the same three record types as the first log, but new data will overwrite old data as the memory is filled. If a pump system safety should occur, this data log shall stop recording and overwriting data so that the data prior to the pump system shutdown can be viewed. After this log is downloaded to the G%;O �plied personal computer, the data log shall resume its activities. This data log shall consist of 1250 data points as described above. F 34.8 The monitoring systems shall be capable of recording each of the data logs independent of the custommer supplied• personal computer. The monitoring system shall be capable of downloading the data from the pump system to the personal computer for r storage and subsequent viewing. 34.9 The monitoring system shall be capable of displaying the `\ recorded data in graphic form on the monitor of the personal computer, as well as providing the capability to produce hard printouts using an IBM Proprinter-compatible printer. 134.10 The manufacturer shall provide one of two possible communications methods for the monitoring system. 34.11 The Direct Connect or Land Line method shall consist of CAi3 hardware allowing the pump system to be monitored via 18 ga.,p 2 -pair, shielded and armored, direct burial communications cable. This cable shall be as belden 1063A or equal. Communications using this method shall be capable of attaining at least 10,000 feet of distance at rates of 2400 Baud minimum. 34.12 The Dial Up telephone method shall consist of hardware --p which allows the pump system to be monitored via RJ -11 (standard) telephone lines. Communications using this method shall be capable of attaining rates of up to 1200 baud. This method shall allow multiple personal computers, -which have the proper software, to communicate with the monitoring hardware located at the pum��.sys'tem. Only one personal computer shall be -able to commufiicate with the pump system monitor at any one time. �NL<..o �w 34.13 The manufacturer shall supply all necessary hardware and software for the monitoring system xcept for the following Owµ n cuetemer-&upp-lied equipment: 100% IBM compatible personal 5✓p�' �� computer (PC, XT, AT, PS -2) with: DOS 2.0 or later operating system, at least 640K available memory, CGA, EGA, or VGA video adapter and monitor, fixed disk drive with at least 1 MB available storage space, serial communications port available as either COM1 or COM2. Pg 12 7228 elm 10/92 unnm STEMS. 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 BOLTS 38.0 All bolts used in the assembly of the pumping system shall be cadmium -plated to retard corrosion. INSTALLATION OF PUMP SYSTEM 41 0__ Purchaser will be required to provide equipment and OiJF'Foj personnel at the job site to locate and set station, install-' ,�5;nw pumps (if vertical turbine) and connect power and discharge piping for main irrigation line. 41.1 Pumping system manufacturer shall not be responsible for the off-loading of the pumping system at the job site. Pumping system manufacturer shall not be responsible for off-loading equipment used to off-load the pumping system. Pumping system manufacturer shall not be responsible for the installation of the pump station. FIELD TESTING 43.0 The complete pumping system shall operate without undue vibration throughout the range of operating conditions. The unit shall be given a running test of normal start and stop conditions under load. During each test eachp pum shall demonstrate its ability to operate without undue vibration or overheating and shall demonstrate without question its general fitness for service. All defects shall be corrected and adjustments made at the expense of the manufacturer. Test shall be repeated until satisfactory results are obtained. PAYMENT 44.0 Full payment shall be made in accordance with the terms of the Confirmation Letter or other mutually acceptable payment terms. If payment is not made as specified, the manufacturer is not liable for warranty service. Payment shall constitute full compensation for all labor, materials and equipment. FACTORY AUTHORIZED WARRANTY 45.0 PSI,warrant4 that the water pumping system or component will be free of defects in workmanship: 1. For tw6 ears from date of authorized start up but not later than --- seven months from date of.P&r invoice. 2. Eligh--speed--pump and motors (3600 RPM) and systems that are not --protected by an individual -phase safety device are limited to one year from date of authorized start up but not later than fifteen months from date of PSI invoice. 3. For Variable Frequency Drive systems, PSI extends the warranty on the control devices (those items contained within the enclosures) for an - additional year. This provision is contingent upon twice yearly preventative maintenance performed by a factory authorized technician during the warranty period. Pg 13 7228 elm 10/92 �r:Jcns. 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 3571320 �,,o (?r P NEf✓ 03 / c� FAX (214) 357-5861 e P� Provi d that all installation, maintenance and operation 915c respons bilities have been properly performed, PSI will repair or replace (at PSI option) the defective pumping system or component provided that PSI is consulted prior to repair. The start up certificate must be on file at PSI factory to activate; i'arranty. PSI will be responsible, subject to standard rate limitations, f for cost of pa�t� removal, installation, and transportation for a C�fc[ failure within fiinety days of authorized and registered start up. Lja Upon request, PSI ill provide advice for trouble' shooting and repair of a defect. PSI equipment incorporates high quality material and components. As with any mechanical or.electrical device, some preventative maintenance efforts are required to enhance service life. The 1'1 customer is encouraged to'establish a.'methodical maintenance service program to avoid prem4ure failure. PSI supports a wide network of technical service -agentsand recommends they be utilized for service. Because of varied conditions beyond the control of manufacturer, this warranty does not cover damage under the following condition .or environment unless otherwise specified in writing. 1. Default of any agreement with PSI. �JIOt" r6� 2. Misuse, abuse, or failure to conduct routine maintenance. 3. Handling any liquid other than irrigation "ter. 4. Exposure to electrolysis, erosion, or abrasioh->� 5. Presence of destructive gaseous or chemical solutions. 6. Over -voltage or unprotected low voltage. 7. Unprotected electrical phase loss of phase reversal., THE FOREGOING CONSTITUTES PSI'S SOLE WARRANTY AND HAS NOT MADE, NOR DOES IT MAKE ANY ADDITIONAL WARRANTY, WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PUMPING SYSTEM OR COMPONENT. PSI MAKES NO WARRANTY, WHETHER EXPRESSED OR IMPLIED, WITH RESPECT TO FITNESS F9k A PARTICULAR PURPOSE OR MERCHANTABILITY OF THE PUMPING SYSTEM OR COMPONENT. PSI SHALI/NOT BE LIABLE TO PURCHASER OR ANY OTHER PERSON FOR ANY LIABILI , LOSS, OR DAMAGE CAUSED OR ALLEGED TO BE CAUSED, DIRECT OR INDIRECTLY, BY THE PUMPING SYSTEM. IN NO EVENT SHALL PSI B RESPONSIBLE FOR INCIDENTAL, CONSEQUENTIAL OR ACT OF GOD DAMAGES NOR SHALL PSI'S LIABILITY FOR DAMAGES TO PURCHASER OR ANY OTHER PERSON EVER EXCEED THE ORIGINAL FACTORY PURCHASE PRICE. MAN 46.0 The umping system shall be of the type manufactured by Pumping Systems; I c., of Dallas, Texas, USA, or equal approved by the architect/en er prior to bid opening. These specifications shall re bace._ any previously proposed specifications, regardless of soarsse_,. If the PSI design is accep-t- , bricated pumping sys-will be built to this Pg14 7228 elm 10/92 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 specifications. PSI shall not be liable for any such differences should the purchaser select the PSI design. For consideration of proposed equal pumping system, the contractor shall submit to the customer or his designee not less than seven days prior to the date of bid opening the following data: 46.1 A set of complete specifications on the pumping system proposed as an equal; 46.2 A set of pump performance curves for each pump; 46.3 Complete station dimension prints showing outside dimensions and complete station piping; 46.4 Pump station manufacturer's U.L. file Number 46.5 A manufacturer's reference list of similar irrigation pump systems. 46.6 Pumping systems manufacturer shall also provide proof of a single incorporation for a minimum of fifteen (15) years to demonstrate manufacturer's solvency and long-term capability to provide reliable service to the customer. 46.7 If the data submitted, in the opinion of the architect/ engineer, shows the proposed pumping system to be an equal to the system specified herein, the architect/ engineer shall notify the contractor not less than three (3) days prior to bid opening. Pg 15 7228 elm 10/92 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 Automatic Vertical Turbine Pumping System Technical Specifications Pumping System Model No. CWTP-1000-3-1800-VFD Total Design Criteria: Quantity of Pumps: 3 Total Design Flow: 1000 Discharge Pressure: 125 Station performance is based on a maximum lift of five feet measured from grade to static water level. Pump Data: Pump Design R.P.M. Eff. At Shutoff Column Shaft Disch. No. G.P.M. Design Head Pipe ID OD Size 1 30 3600 65% 410' 2" .750" 2" 2 500 1800 818 340' 6" 1.19" 6" 3 500 1800 818 340, 6" 1.19" 6" Pump Overall Length: 9' 61' Minimum water coverage as measured from eye of bottom impeller: 241r Pump Check Valve Pump Size Rating No. In psi 1 2" 400 2 6" 400 3 6" 400 psi Drop At Pump Capacity 1 1 Relief Valve Size: 3" Pressure Rating: 200 psi Pilot Setting:linepress 145 Flowsensor Brass , Pressure Rating: 400psi System Isolation Valve: 8' Pressure Rating: 200 psi Service Entrance; 200 Amps, 200,000 Fault Amps, 110 KVA 460 Volts 3 Phase 60 HZ Pg 16 7228 elm 10/92 �unrma sm. 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 Motor Starting Code G, Class F Insulation Motor H.P. R.P.M. Service Eff.% No. Factor 1 3 3600 2 50 1800 3 50 1800 CFM REQUIREMENTS: Motor No. 1 50 Hp.: Motor No. 2 50 Hp.: VFD AC Power Factor 1.15 81% 88% 1.15 90.5% 87% 1.15 90.5% 87% 320 320 550 TOTAL CFM REQUIREMENT: 1190 SUBMERSIBLE VHS VHS Starting Equipment - U.L. Listed as Industrial Control Assembly: Main Disconnect: 600 Volts, 200 Amps. Motor Disconnect Rating Fuse Fuse AIC NEMA Size O.L. Rating No. Volts Amps Amps Rating Starter In Amps HP 1 3 600 17 6 200,000 OXL 4.8 2 50 600 90 75 200,000 3 VFD 65 3 50 600 90 75 200,000 3XL 65 VFD Controls U.L. Listed as Industrial Control Assembly: Operating Temp: 0 to 40 Degree C (32 to 104 F.) Humidity: 5-95% Non -condensing Minimum Efficiency (full load, base speed) 98% Electrical Data: Line Reactor 75 KVA 3% Input Voltage: 3 phase 480 volt AC Input Frequency: 50/60 HZ. Output voltage: 3 phase 0-480 volt AC Frequency Rating: 100% continuous drive rating, Intermittent 111% Drive rating for one minute. Control Circuit Voltage: Internal 90 Volt AC Drive shall be of the Pulse Width Modulated (PWM) type, Current & voltage source drives are unacceptable. LED Indicators shall provide: Power on, Overload, Under Voltage, Over Voltage, "A","B","C" Phase protection, Drive Over Temp, and Output Grounded Diagnostics. Pg 17 7228 elm 10/92 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861 Controls U.L. Listed as Industrial Control Assembly: Phase Failure and low voltage shutoff at 90% of motor name plate voltage on all three legs 83% on one leg for five seconds. Low discharge pressure shutdown at 105 psi after all pumps are running for 60 seconds continuously. High discharge pressure shutdown at 150 psi after all pumps are running for 60 seconds continuously. Low water level safety shutdown if water falls to within two feet of pump suction. P17 7228 elm 10/92 END 6 10717 HARRY HINES BLVD. DALLAS, TEXAS 75220 (214) 357-1320 FAX (214) 357-5861