HomeMy WebLinkAbout2009 - SJRWMD Construction PlansCARNATIOND�R
� SEAGRAS
KENO
IN
STIAN
PROJECT
LOCATION
LOCATION MAP
0
BEACHI2
Improvements
Street [Ditch
INDIAN RIVER COUNTY, FLORIDAI
GNOF
c
Engineering By:
NEEL-SCHAIFFERI[
14L
SOLUTIONS YOU CA/V BUILD UPON
1201 loth Place, Suite A-100
Vero peach, Florida 32960
Phone: 772 770-4707 FAX: (772) 770-4640 CA 00008556
MAYOR
JIM HILI_
VICE MAYOR
COUNCIL. MEMBER
®ALE I. SIMCHICK
COUNCIL MEMBER
EUGiENE WOLFF
COUNCIL. MEMBER
L41A ova 1 r
®AVID FISHER, P.E.
CITY ENGINEER
FRANK T. WATANABE, P.E. FLORIDA
REG. No. 66735
REVISED:
ISSUED:
Project Number:
JUNE 2009
APRIL 2009
N S .07600.001
SHEET INDEX
C-1
G2
G3
CD -1
CD -2
COVER SHEET
GENERAL NOTES
EXISTING CONDITIONS AND PROPOSED IMPROVEMENTS
MISCELLANEOUS DETAILS
MISCELLANEOUS DETAILS
MAYOR
JIM HILI_
VICE MAYOR
COUNCIL. MEMBER
®ALE I. SIMCHICK
COUNCIL MEMBER
EUGiENE WOLFF
COUNCIL. MEMBER
L41A ova 1 r
®AVID FISHER, P.E.
CITY ENGINEER
FRANK T. WATANABE, P.E. FLORIDA
REG. No. 66735
REVISED:
ISSUED:
Project Number:
JUNE 2009
APRIL 2009
N S .07600.001
GENERAL NOTES
1. ALL CONSTRUCTION SHALL BE CONDUCTED IN ACCORDANCE WITH CITY OF SEBASTIAN
ENGINE ERING AND PUBLIC WORKS AND THE FDOT STANDARD SPECIFICATIONS FOR
ROADIc; AND BRIDGES, LATEST EDITION.
2. LOCATIONS, ELEVATIONS, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES, AND
OTHER FEATURES ARE SHOWN ACCORDING TO INFORMATION AVAILABLE AT THE TIME
OF PREPARATION OF THESE PLANS, BUT DO NOT PURPORT TO BE ABSOLUTELY
CORRECT. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL VERIFY AND AGREE TO
BE FUH Y RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY
HIS FAII .URE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL EXISTING UTILITIES,
STRUC I'URES, AND OTHER FEATURES AFFECTING HIS WORK.
3. CONTpACTOR SHALL COORDINATE WITH UTILITY OWNERS FOR VERIFICATION OF ALL
UTILITII .S AND NOTIFY UTILITY OWNERS 72 HOURS PRIOR TO DIGGING IN ANY PORTION
OF THF SITE.
4, THE CONTRACTOR SHALL CONTACT THE ENGINEER UPON FINDING ANY CONFLICTS IN
THE P1 ANS DURING CONSTRUCTION OF ANY IMPROVEMENTS SHOWN ON THE DRAWINGS.
5. THE LIMITS OF CONSTRUCTION SHOWN ON THE PLANS SHALL BE STRICTLY OBSERVED BY
THE CO )NTRACTOR. ALL INGRESS, EGRESS AND TRAFFIC PATTERNS ON THE SITE SHALL
BE EXI DING ROADWAYS SHOWN ON THE DRAWINGS.
6. FINISHI=D GRADE FOR GROUND ELEVATIONS ON DRAWINGS REFER TO GRADE AFTER
SODDILIG OR OTHER SURFACE TREATMENT. FINISHED ELEVATIONS SHOWN ON
DRAWII IGS REFER TO ELEVATIONS AFTER CONCRETE OR ASPHALT PAVEMENT.
7. INSTALI .ATION OF ALL CONDUITS, PULL BOXES AND FOUNDATIONS SHALL BE IN
ACCOPI)ANCE WITH ALL REQUIREMENTS OF THE APPLICABLE SECTIONS OF THE FLORIDA
DEPAR I MENT OF TRANSPORTATION STANDARD SPECIFICATIONS, FDOT ROADWAY AND
TRAFFI'% DESIGN STANDARDS AND AS INDICATED ON THE DRAWINGS AND/OR, BY THE
MANUFACTURER.
8. CONTpACTOR IS RESPONSIBLE FOR ALL COSTS OF ALL TESTINGS BY AN INDEPENDENT
GEOTECHNICAL SOILS AND MATERIALS TESTING LABORATORY. THE COST OF ALL
TESTINGS REQUIRED BY THESE PLANS & SPECIFICATIONS SHALL BE INCLUDED WITH THE
LUMP (SUM BID AND NO ADDITIONAL COMPENSATION SHALL BE MADE BY THE OWNER.
9. THE CO �NTRACTOR IS RESPONSIBLE TO OBTAIN ALL REQUIRED BUILDING PERMITS FOR
THIS PI-,.OJECT AND SHALL COORDINATE ALL ACTIVITIES WITH CITY OF SEBASTIAN.
10. UNLES' OTHERWISE SHOWN, THE CONTRACTOR SHALL REPLACE ALL PAVING, SODDING,
STABILIZED EARTH, LANDSCAPING, DRIVEWAYS, SIDEWALKS, IRRIGATION SYSTEMS,
UNDERGROUND PIPING, ETC. LOCATED WITHIN AND OUTSIDE THE CONSTRUCTION LIMIT
LINE DISTURBED OR DAMAGED BY THE CONSTRUCTION. THE CONTRACTOR SHALL
REPLA(oE WITH EQUAL MATERIAL OR AS DIRECTED BY THE ENGINEER.
11. WHERI A CONNECTION IS TO BE MADE IN THE FIELD TO AN EXISTING CONDUIT, THE
CONTPI-�CTOR SHALL EXCAVATE THE AREA TO VERIFY THE TYPE OF CONDUIT, CONDUIT
SIZE, AI ID REQUIRED CONNECTION AND FITTINGS AND OBTAIN THE OWNERS APPROVAL
OF THl PROPOSED METHOD OF CONNECTION PRIOR TO INSTALLING MATERIALS.
12. THE C0NTRACTOR SHALL COORDINATE AND VERIFY ALL DIMENSIONS OF ALL EXISTING
AND PI=OPOSED FACILITIES PRIOR TO FABRICATION OF PIPING AND EQUIPMENT TO
ENSURF- PROPER ASSEMBLY OF ALL ITEMS. SOME DIMENSIONS MAY NEED TO BE
VERIFIED BY THE CONTRACTOR, FROM THE MANUFACTURER.
13. THE CONTRACTOR IS TO FOLLOW THE CONSTRUCTION PERMITS THAT HAVE BEEN ISSUED
FOR THIS PROJECT. ALL SPECIFIC OR GENERAL CONDITIONS APPLY.
14. THE CONTRACTOR IS TO ADHERE TO THE DESIGN AND CONSTRUCTION STANDARDS OF
CITY 01 SEBASTIAN.
15. MAINTENANCE OF TRAFFIC SHALL BE IN ACCORDANCE WITH THE MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES PART Vi, WORK ZONE TRAFFIC CONTROL. CONTRACTOR TO
PROVIDE MAINTENANCE OF TRAFFIC PLAN TO ENGINEER PRIOR TO CONSTRUCTION.
TRAFFIC CIRCULATION WITHIN EXISTING PARKING LOT AREA MUST BE MAINTAINED
DURING CONSTRUCTION.
16. COMPLETE RECORD DRAWINGS, CONFORMING TO CITY OF SEBASTIAN STANDARDS
SHALL BE COMPILED DURING CONSTRUCTION FOR PERIODIC REVIEW. FINAL RECORD
DRAWINGS, CERTIFIED BY A FLORIDA LICENSED REGISTERED LAND SURVEYOR SHALL BE
SUBMITTED TO THE ENGINEER IN DIGITAL FORMAT PRIOR TO FINAL INSPECTION AND
ACCEPTANCE ON ANY PART OF THE PROJECT.
17. LOCATIONS AND DIMENSIONS OF EXISTING RIGHTS-OF-WAY AND EASEMENTS ARE BASED
ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL VERIFY THE LIMITS OF THE
RIGHTS-OF-WAY AND EASEMENTS IN ORDER TO AVOID ENCROACHMENTS.
18. THE CONTRACTOR SHALL MAKE EXPLORATORY EXCAVATIONS AT ALL INTERSECTIONS OF
PROPOSED WORK AND EXISTING UTILITIES. THE EXPLORATORY EXCAVATIONS SHALL BE
MADE SEVENTY-TWO (72) HOURS IN ADVANCE OF THE WORK. IF THERE IS A POTENTIAL
CONFLICT, THE CONTRACTOR IS TO NOTIFY OBSTRUCTION SHALL BE FURNISHED BY THE
CONTRACTOR THE OWNER IMMEDIATELY. INFORMATION ON THE AND SHALL INCLUDE:
LOCATION, ELEVATION, UTILITY TYPE, MATERIAL AND SIZE. CONTRACTOR SHALL RAISE
OR LOWER THE INSTALLED PIPE AS NEEDED AT NO EXTRA EXPENSE TO THE OWNER.
19. ELEVATION DATUM IS LOCAL DATUM.
20. IN AREAS WHERE CONSTRUCTION ACTIVITIES RESTRICT NORMAL ACCESS TO
PROPERTIES, THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ALTERNATIVE ACCESS
ROUTES, WHICH ARE SUBJECT TO APPROVAL BY THE ENGINEER.
21. THE CONTRACTOR SHALL NOTIFY THE OWNER 72 HOURS IN ADVANCE OF ANY WATER
MAIN OR SANITARY FORCE MAIN SHUT -DOWN.
22. ALL EXCAVATIONS SHALL BE BACKFILLED AT THE END OF EACH WORK DAY.
23. THE Cr)NTRACTOR SHALL NOTIFY FIBER OPTICS COMPANIES SEVEN (7) DAYS PRIOR TO
ANY CONSTRUCTION. EXTREME CAUTION SHALL BE EXERCISED IN AREAS OF FIBER
OPTIC':.
24. CONTPACTOR SHALL BE RESPONSIBLE FOR REPLACING DAMAGED CURBS, ASPHALT,
LANDSCAPING, DRIVEWAYS AND ANY TEMPORARY REPAIRS OF OPEN CUTS. THESE
ITEMS SHALL BE PAID UNDER GENERAL REQUIREMENTS.
25. CONTRACTOR SHALL MAINTAIN PEDESTRIAN TRAFFIC, I.E. TEMPORARY SIDEWALKS
AROUND WORK AREAS, CONTRACTOR MAY HAVE TO RESTRICT WORK HOURS ON
SIDEWALKS, TO RESTORE IMMEDIATELY AND ERECT TEMPORARY FENCING BETWEEN
CONSTRUCTION AND TEMPORARY SIDEWALKS, ETC.
26. ALL CONSTRUCTION CONTROL SHALL BE REFERENCED AND REPLACED BY FLORIDA
REGISTERED LAND SURVEYOR AFTER CONSTRUCTION.
27. PIPES SHALL NOT BE DEFLECTED MORE THAN 75% OF THE MANUFACTURER'S
RECOMMENDATIONS.
NOTICE TO DRAWING HOLDER
,E DRAWINGS. IF ANY DISCREPANCIES OCCUR WITHIN THESE
. JNTRACTOR SHALL CONTACT NEEL-SCHAFFER, INC. FOR
DO NOT SCALE THE- OR TO CONSTRUCTION. NEEL-SCHAFFER, INC., HEREINAFTER
DOCUMENTS, THE (;,E, ENGINEER HAS PREPARED AND FURNISHED THIS DRAWING TO
CLARIFICATIONS PF
REFERRED TO AS Ti.E ON THIS PROJECT ONLY, THIS DRAWING SHOULD NOT BE USED
THE OWNER FOR UA THIS PROJECT OR ON ANY OTHER PROJECT. ANY REUSE OF THIS
ON EXTENSIONS OF�WRITTEN VERIFICATION OR ADAPTION BY THE ENGINEER, SHALL
a SOLE RISK AND THE REUSER SHALL INDEMNIFY AND HOLD
DRAWING, WITH01'11INEER FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES,
AT TUG RFI ISE' =Y'S FEES ARISING OUT OF OR RESULTING THEREFROM.
48 HOURS BEFORE DIGGING
CALL TOLL FREE
1-300-432'-4110
SUNSHINE STATE ONE CALL
OF FLORIDA, INC.
NO. DATE
1. 06-11-09 BY
Mi DS
1. CONTRACTOR SHALL ADHERE TO THE REQUIREMENTS SET FORTH IN THE MANUAL. ON
UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) LATEST PUBLISHED EDITION. CHAI YTER
VI AND THE FDOT ROADWAY AND TRAFFIC DESIGN STANDARDS LATEST PUBLISHEi1
EDITION AT ALL TIMES.
2. ALL TRAFFIC CONTROL DEVICES (TEMPORARY SIGNS, PAVEMENT MARKINGS, BARRIER
WALLS, ETC.) REQUIRED DURING A CONSTRUCTION PHASE SHALL BE INSTALLED AND
APPROVED BY THE CITY OF SEBASTIAN TRAFFIC OPERATIONS ENGINEER PRIOR TO THE
COMMENCEMENT OF CONSTRUCTION AND WILL BE MAINTAINED IN ACCORDANCE WITH
MUTCD REFER TO INDEX 600. IF CASE IS NOT COVERED IN MUTCD INDEX 600 SHALL BE
USED IN CONJUNCTION WITH ALL OTHER INDEXES SPECIFICALLY MENTIONED IN EACH
TRAFFIC CONTROL PHASE.
3. ALL EXISTING SIGNS AND PAVEMENT MARKINGS WHICH CONFLICT WITH THE TRAFFIC
CONTROL PLAN DURING A CONSTRUCTION PHASE SHALL BE REMOVED OR TEMPORARILY
RELOCATED AS NECESSARY PRIOR TO COMMENCEMENT OF CONSTRUCTION. THF COST
OF REMOVING AND/OR REPLACING SIGNS AND PAVEMENT MARKINGS FOR MAINTENANCE
OF TRAFFIC SHALL BE INCLUDED UNDER PAY ITEM 1-3.
4. ALL SIGNS 48" X 48" OR LARGER SHALL BE MAINTAINED ON TWO (2) BREAKAWAY
SUPPORTS OR YIELDING POST AS SHOWN IN FIGURE 6-1 OF THE MUTCD. THE
CONTRACTOR SHALL USE THE MUTCD TO DETERMINE THE APPROPRIATE PLACEMI_NT
AND ELEVATION OF CONSTRUCTION SIGN. REFLECTIVITY SHALL ADHERE TO THE I DOT
STANDARD SPECIFICATION FOR ROADS AND BRIDGE CONSTRUCTION LATEST PUFfI.ISHED
EDITION.
5. AT THE COMPLETION OF CONSTRUCTION DAY THE ROAD SHALL BE RETURNED TO
TWO-WAY TRAFFIC.
6. VEHICULAR ACCESS TO RESIDENCES WILL BE MAINTAINED AT ALL TIMES.
7. PROVISIONS APPROVED BY THE PROJECT ENGINEER WILL BE MADE FOR THE REMOVAL
OF STORM WATER FROM THE ROADWAY DURING CONSTRUCTION.
8. ALL TEMPORARY MARKINGS SHALL BE IN PLACE ONE (1) HOUR BEFORE SUNSET.
9. ALL DEVICES WILL BE IN GOOD CONDITION. MINIMUM REFLECTIVE INTENSITY SHALL
MEET THE FDOT STANDARD SPECIFICATIONS FOR ROADS AND BRIDGE CONSTRUCTION
LATEST PUBLISHED EDITION.
10. INGRESS/EGRESS TO COMPLEX MUST BE MAINTAINED THROUGHOUT CONSTRUCTION
SCHEDULE.
EROSION CONTROL/WATER QUALITY NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING AN EROSION CONTROL
PLAN AT THE TIME OF PRE -CONSTRUCTION CONFERENCE. THE PROPOSED EROSION
CONTROL PLAN SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CRITERIA SET FORTH
IN THE FDOT STANDARD SPECIFICATIONS FOR ROADS AND FDEP LAND DEVELOPMI NT
MANUAL SHALL BE SUBJECT TO APPROVAL BY LOCAL GOVERNMENTS AND WATER
MANAGEMENT DISTRICT HAVING JURISDICTION.
2. EROSION CONTROL AND SEDIMENTATION CONTROL DEVICES SHALL BE IN PLACE F'I�IOR
TO BEGINNING ANY CONSTRUCTION. THEY SHALL BE INSTALLED, ATA MINIMUM, T�) THE
LIMITS SHOWN IN THE DRAWING, AS REQUIRED IN THE SPECIFICATIONS AND IN
ACCORDANCE WITH ALL REGULATORY AGENCY REQUIREMENTS. THE COST TO THE
CONTRACTOR FOR ALL EROSION AND SEDIMENTATION CONTROL IS INCLUDED IN THE
LUMP SUM BID AND NO ADDITIONAL COMPENSATION SHALL BE MADE BY THE OWNER.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE OF ALL TEMPORAPY
EROSION CONTROL FEATURES.
4. CONTRACTOR IS TO PROVIDE EROSION/SEDIMENTATION CONTROL TO PREVENT
SILTATION OF ADJACENT PROPERTY, STREETS, STORM SEWERS AND WATER WAYS. IN
ADDITION, CONTRACTOR SHALL PLACE STRAW, MULCH OR OTHER SUITABLE MATERIAL
ON GROUND ON AREAS WHERE CONSTRUCTION -RELATED TRAFFIC IS TO ENTER AND EXIT
SITE. IF, IN THE OPINION OF THE ENGINEER AND/OR LOCAL AUTHORITIES, EXCESSIVE
QUANTITIES OF EARTH ARE TRANSPORTED OFF-SITE EITHER BY NATURAL DRAINAGE OR
BY VEHICULAR TRAFFIC, THE CONTRACTOR IS TO REMOVE AND CLEAN SAID EARTH TO
THE SATISFACTION OF THE ENGINEER AND/OR AUTHORITIES. AN EROSION CONTROL
BARRIER SHALL BE ESTABLISHED AS SITE CLEARING PROCEEDS AND MAINTAINED UNTIL
SUCH TIME AS VEGETATION OR OTHER CONTROLS BECOME EFFECTIVE.
5. EXISTING DRAINAGE PATTERNS AND CAPACITIES ARE TO BE PROTECTED AND
MAINTAINED DURING CONSTRUCTION TO ELIMINATE FLOODING AND PONDING WATER ON
PRIVATE PROPERTY. CONTRACTOR TO PROVIDE TEMPORARY DRAINAGE MEASURES AS
REQUIRED TO MEET THIS REQUIREMENT.
SPECIAL CONDITIONS
1. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH BELLSOUTH, CABLE TV, F.P.L.
& I.R.C. UTILITY DEPARTMENT FOR SCHEDULING INSTALLATION AND OR INSPECTIONS WITH REGARD
TO THEIR RESPECTIVE SERVICES.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, REPAIR, REINSTALLATION OR
RECONSTRUCTION OF PRIVATELY OWNED ITEMS (MAILBOXES, FENCE, ET. AL.) WITHIN
PROJECT LIMITS. CONTRACTOR SHALL TAKE DUE CARE AS TO NOT ADVERSELY IMPACT
PRIVATE CITIZENS & THEIR ABILITY TO USE SUCH ITEMS.
3. CONTRACTOR SHALL PREPARE & SUBMIT FOR REVIEW A PROJECT MAINTENANCE
OF TRAFFIC PLAN. THIS PLAN SHALL BE PREPARED TO INSURE RESIDENTS & BUSINESS
OWNERS WITHIN THE PROJECT LIMITS SHALL HAVE REASONABLE & CONTINUOUS
ACCESS TO THEIR PROPERTIES DURING THE CONSTRUCTION PHASE.
4. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE SHOP DRAWINGS PRIOR TO START OF
CONSTRUCTION.
REVISIONS
DESCRIPTION
RESPONSE TO SJRWMD RAI DATED 05-06-09
DRAWING INFORMATION
FILENAME: GEORGEST. DITCH
SCALE: 1"= 10'
SURVEYED BY: HSBS
DSGN: FTW DATE: 04-17-09
DRWN:
MDS
DATE:
06-11-09
CHKD:
LGM
DATE:
06-15-09
QAIQC:
FTW
DATE:
06-15-09
MINIMUM STANDARDS
1. SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMERI I- BARRIERS
AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHAT I -BE
CONSTRUCTED AS A FIRST STEP IN LAND -DISTURBING ACTIVITY AND
SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DIST! IRBANCE
TAKES PLACE.
2• SEDIMENT CONTROL MEASURES ARE TO BE ADJUSTED TO MEET
FIELD CONDITIONS AT THE TIME OF CONSTRUCTION AND BE
CONSTRUCTED PRIOR TO GRADING OR DISTURBANCE OF EXISTING
SURFACE MATERIAL ON BALANCE OF SITE. PERIMETER SEDIMENT
BARRIERS SHALL BE CONSTRUCTED TO PREVENT SEDIMENT OR TRASH
FROM FLOWING OR FLOATING ONTO ADJACENT PROPERTIES.
3• PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BP_ APPLIED TO
DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED
ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL
BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT
BE AT FINAL GRADE BUT WILL REMAIN UNDISTURBED FOR LONGER THAN
30 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED To AREAS
THAT ARE TO BE LEFT UNDISTURBED FOR MORE THAN ONF YEAR.
4• DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILI S SHALL BE
STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES.
THE CONTRACTOR IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND
PERMANENT STABILIZATION OF SOIL STOCKPILES ON SITE AS WELL AS
SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE.
5• A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON
DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED.
PERMANENT VEGETATION SHALL BE CONSIDERED ESTABLISHED
UNTIL A GROUND COVER IS ACHIEVED THAT, IN THE OPINION OF THE
REVIEWER, IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL
INHIBIT EROSION.
6• STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES
SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER
INSTALLATION,
7, SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW
FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THRf_E ACRES SHALL
BE CONTROLLED BY A SEDIMENT BASIN. THE SEDIMENT BA:IN SHALL
BE DESIGNED AND CONSTRUCTED TO ACCOMMODATE THE ANTICIPATED
SEDIMENT LOADING FROM THE LAND -DISTURBING ACTIVITY. THE
OUTFALL DEVICE OR SYSTEM DESIGN SHALL TAKE INTO ACCOUNT THE
TOTAL DRAINAGE AREA FLOWING THROUGH THE DISTURBED AREA TO BE
SERVED BY THE BASIN.
8. AFTER SIGNIFICANT RAINFALL, SEDIMENT CONTROL STRUC 1 HIRES WILL
BE INSPECTED FOR INTEGRITY. DAMAGED DEVICES SHALL fir
CORRECTED BY THE CONTRACTOR IMMEDIATELY.
9. CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FELL SLOPES
UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT
CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE.
10. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE
OR OTHER PROTECTION SHALL BE PROVIDED.
11. SEDIMENT WILL BE PREVENTED FROM ENTERING ANY STORM DRAIN
SYSTEM, DITCH OR CHANNEL. ALL STORM WATER INLETS THAT ARE
MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT
SEDIMENT -LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM
WITHOUT FIRST BEING FILTERED OR OTHER WISE TREATED TO REMOVE
SEDIMENT.
12. UNDERGROUND UTILITY POWER LINES SHALL BE INSTALLED IN ACCORDANCE
WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE
CRITERIA:
(a) NO MORE THAN 500 LINEAR FEET OF TRENCH
MAY BE OPENED AT ONE TIME.
(b) EXCAVATED MATERIAL SHALL BE PLACED ON THE
UPHILL SIDE OF TRENCHES.
(c) EFFLUENT FROM DEWATERING OPERATIONS SHALL BE
FILTERED OR PASSED THROUGH AN APPROVED
SEDIMENT TRAPPING DEVICE, OR BOTH, AND
DISCHARGED IN A MANNER THAT DOES NOT
ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE
PROPERTY.
(d) RESTABLIIZATION SHALL BE ACCOMPLISHED IN
ACCORDANCE WITH THESE REGULATIONS.
13. WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED
PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE
TRANSPORT OF SEDIMENT BY TRACKING ONTO THE PAVED SURFACE.
WHERE SEDIMENT IS TRANSPORTED ONTO A PUBLIC ROAD SURFACE
WITH CURBS AND GUTTERS, THE ROAD SHALL BE CLEANED THOROUGHLY
AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE
ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT
CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY
AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION
SHALL APPLY TO INDIVIDUAL SUBDIVISION LOTS AS WELL AS TO LARGER
LAND -DISTURBING ACTIVITIES.
14. TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL
BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR
AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, IN THE
OPINION OF THE PROJECT ENGINEER. DISTURBED SOIL AREAS RESULTING FROM
THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY
STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION.
15. PROPERTIES AND WATERWAYS DOWNSTREAM FROM CONSTRUCTION SITES
SMALL BE PROTECTED FROM SEDIMENT DEPOSITION AND EROSION.
16. EROSION CONTROL DESIGN AND CONSTRUCTION SHALL FOLLOW THE REQUIREMENTS IN
INDEX Nos. 101, 102 AND 103 OF FDOT ROADWAY AND TRAFFIC DESIGN STANDARDS.
17. PERIODIC INSPECTION AND MAINTENANCE OF SEDIMENT CONTROL STRUCTURES MUST
BE PROVIDED TO ENSURE INTENDED PURPOSE IS ACCOMPLISHED. THE OWNER AND
CONTRACTOR SHALL BE CONTINUALLY RESPONSIBLE FOR SEDIMENT LEAVING THE
PROPERTY. SEDIMENT CONTROL MEASURES SHALL BE IN WORKING CONDITION AT THE
END OF EACH WORKING DAY.
OL ,qmkl
NEEL-SCRAFFER
SOLUTIONS YOU CAN BUILD UPON
1201 19th Place, Suite A-10CI Vera Beach,
Florida 32960 PH: (772) 770-4707
FAX: (772) 770-4640 CM0008556
GENERAL NOTES
CONSTRUCTION IN STREETS, ROAD RIGHTS-OF-WAY
& PARKING AREAS
1. OPEN ROAD CUTS REQUIRE PRIOR APPROVAL OF THE CITY, COUNTY, STATE OR ANY OTHER
AGENCY WHICH MAY HAVE JURISDICTION.
2. CONSTRUCTION, MATERIALS AND WORKMANSHIP ARE TO BE IN ACCORDANCE WITH FLORIDA
DEPARTMENT OF TRANSPORTATION SPECIFICATIONS AND STANDARDS.
3. AREAS IN EXISTING RIGHTS-OF-WAY DISTURBED BY CONSTRUCTION SHALL RECEIVE GRASS,
MULCH OR SOLID SOD, AS STATED ON THE PLANS.
4. STREET OR HIGHWAY RESTORATION TO BE DONE AS PER LOCAL OR STATE AGENCY HAVING
JURISDICTION.
5. THE CONTRACTOR SHALL COMPLY WITH RULES AND REGULATIONS OF THE STATE, COUNTY
AND CITY AUTHORITIES REGARDING CLOSING OR RESTRICTING THE USE OF PUBLIC
STREETS OR HIGHWAYS.
6. TRAFFIC CONTROL ON COUNTY AND STATE HIGHWAY RIGHTS-OF-WAY SHALL MEET THE
REQUIREMENTS OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (U.S. DOT/FHA)
AND THE REQUIREMENTS OF THE STATE AND ANY LOCAL AGENCY HAVING JURISDICTION.
7. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY AND DOCUMENT THE ACTUAL
LOCATION AND EXTENT OF EXISTING UTILITIL.3 WHICH MAY AFFECT CONSTRUCTION.
EXISTING UTILITIES SHOWN ARE BASED UPON THE BEST AVAILABLE INFORMATION SUPPLIED
TO THE OWNER/ENGINEER AND IS SHOWN FOR INFORMATIONAL PURPOSE ONLY.
8. CONTRACTOR IS RESPONSIBLE FOR CHECKING ACTUAL SITE CONDITIONS BEFORE STARTING
CONSTRUCTION.
9. DISCREPANCIES ON THE DRAWINGS SHALL BH BROUGHT TO THE ATTENTION OF THE ENGINEER
BEFORE COMMENCING WORK.
10. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS BEFORE COMMENCING WORK.
11. THE CONTRACTOR SHALL CONTACT ALL IMPACTED UTILITIES AT LEAST 48 HOURS IN ADVANCE
OF CONSTRUCTION OPERATIONS.
12. NO FIELD CHANGES OR DEVIATIONS FROM DI -:-SIGN TO BE MADE WITHOUT PRIOR APPROVAL OF
THE ENGINEER AND THE APPROPRIATE GOVT RNMENTAL ENTITY.
13. ALL MUCK OR OTHER SUCH UNSUITABLE MATERIAL ENCOUNTERED WITHIN ROAD RIGHTS-OF-
WAY AND LOT AREAS SHALL BE FULLY EXCAVATED AND REPLACED WITH CLEAN, ON-SITE FILL
MATERIAL COMPACTED TO 95% MAXIMUM DENSITY. ACTUAL EXTENT AND QUANTITY OF
EXCAVATION SHALL BE DETERMINED AT THE TIME OF CONSTRUCTION BY APPROPRIATE
FIELD MEASUREMENT. DISPOSAL OF UNSUITA13LE MATERIAL SHALL BE AS DIRECTED BY OWNER
OR OWNER'S ENGINEER.
GEORGE STREET DITCH
SEBASTIAN, INDIAN RIVER COUNTY, FLORIDA
FRANK T. WATANABE, P.E.
FL. REG. NO. 66735
WORKING NUMBER:
N.07600.001
SHEET NUMBER:
C-2
CONCRETE PADS -g o
RIP -RAP g
REMOVEB
58 L.F. 43" x 70" RCP \ (APPROXIMATE LOCATION) B.S..
/ AND REPLACE WITH \ \ CONNECT 18' CMP STA T) DO STOCKADE FENCE rn
/ 56 L.F. IWO (2) 43"x 68" ERC \ O
INV. 15.11 _ 00
os TA 1+00 CENTER LINE GEORGE ST. HEDGES
�g top of bank / / x SA 0Pf PAVEMENT AND Ig' X^yg• = STA 1+00 CONTROL IN �� 6' DRAwncE/uTIUTY EASEMENT
6 " top Of bank �N 0 6� STOCKADE F NCE
- / / TRAITION TO EXISTING \ HEDGES �
ROA
10 0 5'X2.5' L g xi / �,•. /° -- \ \ 1 h ! �\ JL! \ _./ /
x �9 / W Hour
8" CMPST7�0�69. / 1.5' EEP RIP RAP INV1500 ,,
N . .�� E - INV�13.55 FILL; COMPACT AND GRADE WITH
5 HE DWALL STA: 1+31.30 / i SOD ON TOP OF DITCH ARE ' \ /
INV. 15.31 g1 1+25.47 x� , A. h AF
/A 3J
0
_\
ASH
N11 Q` HEADWALL /' /\ \ z / -
. _toe o� Q� �.,
- - -� - - - - - - `• 4,C/X 52"'3C 77 .CMP
g
a.
x 43"x70" R.C.P. 5 1 � r,. f 70
INV`. 4.0$, X _
0+50 w INV. -15.31
�_► x % x DONTROL LINE
HD OUT
Q -x--_toe
2.5'X2.5' V_
WASH OUT O1 i
0 1.-" CMP 1 1.5'' DEEP _/ toe
% , \,;_
IAV.=15.86 'J 0
t0'
el ,
o STA 0+69.7 1 O �� N� �
�� /CD\
V. 15.31 \'
IN x \
TILL, COMPACT AND GRADE,WIT1 .�
g. p• f f•• i \ �\ ,x� r
/ \ SO'b ON TOP OF DITCH AR
x1 \ TA 1 25.4. ,
/ ;• 8905 E 12000 0
25.00, V. 15.00 �g / - ---------
FID
0
g r \ f...__...... _
g• PK NAIL ED. FDO J ON -B -OX- _....... �/ _ ..: t•.......__._r_.:.....
.._._. _
/
21 5 top top of bank
of \� x� REMOVE NO DISCARD aINAGE/UTILITY EASEMENT A
ONE
�-
EXISTING HEADWALL
F / r / � N =
g STA 1+29.2 (8.10__RT CO
- c3 0 CONNECT 18" CMP ^� C oN
DEMO EXISTING \ \- B M x�g / INV:,1'4.41 CONCRETE POOL 0
0
ASPHALT \/J ` MB / k ° a d " EQUIPMENT PAD
p✓ ELEV.=20.22 a C 6"
a .o ELEV= O_23.24 - n k B.S.B.
..
4" d CSN CRETE A/C-& PUMP
PAD
I dO
25
-
..............I
_
_...
....
'
...............................-
CO
.. 4G. .d
a. 4 d
_.
I
-
-
-
--
:
_...._.._... _ .......
--
3
NOTE: HOUSE AND DECK
J
n
DETAILS ON THIS LOTd
4
COVERED
0
U N0
ccoo0
ARE (BASED ON A SURVEY
d
CONCRETE °
a
o
+__...-- _................ �Z
HZ
.............. ----_.----................ . .....
-_ ..
¢
PERFORMED & PROVIDED
d
EXISTING ROAD
EXISTING GROUND -1
5MTH SURVEYING &
dBY
d
INC.
aMAPPING,
°
O
JOB 03-0856
12" ADS
O
LOT 8
INV.=18.55
4"
HLOCK 180
aPORCH
s°a
C.113. S SINGLE
VACANT
dFAMILY
°
RESIDENCE
c-,+ 1+50
POOL
(APPROXIMATE)
O
d
..- .
o
°
°
M
dd
4 a
-23.a
E
16' CON
a. -
a '
DRIVE ..
..
o
O
Ln
03
d _ a d
_
V
STA 0+7,0.01
g�
29.59'
18" CMP REMOVE
AND REPLACE
INV. -18. 2 EXISTING
HEADWALLI
g
d de
CONCRETE PADS -g o
RIP -RAP g
REMOVEB
58 L.F. 43" x 70" RCP \ (APPROXIMATE LOCATION) B.S..
/ AND REPLACE WITH \ \ CONNECT 18' CMP STA T) DO STOCKADE FENCE rn
/ 56 L.F. IWO (2) 43"x 68" ERC \ O
INV. 15.11 _ 00
os TA 1+00 CENTER LINE GEORGE ST. HEDGES
�g top of bank / / x SA 0Pf PAVEMENT AND Ig' X^yg• = STA 1+00 CONTROL IN �� 6' DRAwncE/uTIUTY EASEMENT
6 " top Of bank �N 0 6� STOCKADE F NCE
- / / TRAITION TO EXISTING \ HEDGES �
ROA
10 0 5'X2.5' L g xi / �,•. /° -- \ \ 1 h ! �\ JL! \ _./ /
x �9 / W Hour
8" CMPST7�0�69. / 1.5' EEP RIP RAP INV1500 ,,
N . .�� E - INV�13.55 FILL; COMPACT AND GRADE WITH
5 HE DWALL STA: 1+31.30 / i SOD ON TOP OF DITCH ARE ' \ /
INV. 15.31 g1 1+25.47 x� , A. h AF
/A 3J
0
_\
ASH
N11 Q` HEADWALL /' /\ \ z / -
. _toe o� Q� �.,
- - -� - - - - - - `• 4,C/X 52"'3C 77 .CMP
g
a.
x 43"x70" R.C.P. 5 1 � r,. f 70
INV`. 4.0$, X _
0+50 w INV. -15.31
�_► x % x DONTROL LINE
HD OUT
Q -x--_toe
2.5'X2.5' V_
WASH OUT O1 i
0 1.-" CMP 1 1.5'' DEEP _/ toe
% , \,;_
IAV.=15.86 'J 0
t0'
el ,
o STA 0+69.7 1 O �� N� �
�� /CD\
V. 15.31 \'
IN x \
TILL, COMPACT AND GRADE,WIT1 .�
g. p• f f•• i \ �\ ,x� r
/ \ SO'b ON TOP OF DITCH AR
x1 \ TA 1 25.4. ,
/ ;• 8905 E 12000 0
25.00, V. 15.00 �g / - ---------
FID
0
g r \ f...__...... _
g• PK NAIL ED. FDO J ON -B -OX- _....... �/ _ ..: t•.......__._r_.:.....
.._._. _
/
21 5 top top of bank
of \� x� REMOVE NO DISCARD aINAGE/UTILITY EASEMENT A
ONE
�-
EXISTING HEADWALL
F / r / � N =
g STA 1+29.2 (8.10__RT CO
- c3 0 CONNECT 18" CMP ^� C oN
DEMO EXISTING \ \- B M x�g / INV:,1'4.41 CONCRETE POOL 0
0
ASPHALT \/J ` MB / k ° a d " EQUIPMENT PAD
p✓ ELEV.=20.22 a C 6"
a .o ELEV= O_23.24 - n k B.S.B.
..
4" d CSN CRETE A/C-& PUMP
PAD
I dO
25
20
15
W11
NOTICE TO DRAWING HOLDER
THESE DRAWINGS. IF ANY DISCREPANCIES OCCUR WITHIN THESE
HE CONTRACTOR SHALL CONTACT NEEL-SCHAFFER, INC. FOR
DO NOT SCALE'S PRIOR TO CONSTRUCTION, NEEL-SCHAFFER, INC., HEREINAFTER
DOCUMENTS, IRS THE ENGINEER HAS PREPARED AND FURNISHED THIS DRAWING TO
CLARIFICATIONS USE ON THIS PROJECT ONLY, THIS DRAWING SHOULD NOT BE USED
REFERRED TOA'
THE OWNER FO�OFTHIS PROJECT OR Q OTHER PROJECT.
OH
IS
ON EXTENSIONSOUT WRITTEN
RONOADAPTOBHE ENGNEER,SHAL
DRAWING, WITHI'ER'S SOLE RISK AND THE REUSER SHALL INDEMNIFY AND HOLD
^iNGINEER FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES,
BE AT THE REQ
RNEY'S FEES ARISING OUT OF OR RESULTING THEREFROM.
HARMLESS TW-
IKIf l I InlMr. AT
1+00
PROPOSED GROUND
0
Y
LO
COMPACTED FILL Q
U)
IRRIGATION
SYSTEM
INTAKE
(APPROXIMATE)
1.0'
HEADWALL
6 PIPE DITCH AND
b FILL IN AREA
1
REMOVE AND REPLACE
EXISTING SEAWALL
0 STA: 2+51.30 (5.21' LT)
/ O
O
06 �
60" CMP
I V=
13.14
LO
STA: 2+51.30
INV. 13.14
REMOVE AND DISCARD
6 35 L.F. 60" CMP
b VREMOVE AND REPLACE
1k
EXISTING SEAWALL
STA: 2+51.30 (5.21' RT)
INSTALL 120 L.F.
52"x77" CMP
V WITNESS
IRRIGATION
SYSTEM
INTAKE
(APPROXIMATE)
zz::3- 1.0'
HEADWALL
EXISTING CANAL
-
..............I
_
_...
....
'
...............................-
LU_.
_.
I
-
-
-
--
:
_...._.._... _ .......
--
��
J
-
_
m ....... co
m -
0
U N0
ccoo0
o
+__...-- _................ �Z
HZ
.............. ----_.----................ . .....
-_ ..
¢
¢
EXISTING ROAD
EXISTING GROUND -1
20
15
W11
NOTICE TO DRAWING HOLDER
THESE DRAWINGS. IF ANY DISCREPANCIES OCCUR WITHIN THESE
HE CONTRACTOR SHALL CONTACT NEEL-SCHAFFER, INC. FOR
DO NOT SCALE'S PRIOR TO CONSTRUCTION, NEEL-SCHAFFER, INC., HEREINAFTER
DOCUMENTS, IRS THE ENGINEER HAS PREPARED AND FURNISHED THIS DRAWING TO
CLARIFICATIONS USE ON THIS PROJECT ONLY, THIS DRAWING SHOULD NOT BE USED
REFERRED TOA'
THE OWNER FO�OFTHIS PROJECT OR Q OTHER PROJECT.
OH
IS
ON EXTENSIONSOUT WRITTEN
RONOADAPTOBHE ENGNEER,SHAL
DRAWING, WITHI'ER'S SOLE RISK AND THE REUSER SHALL INDEMNIFY AND HOLD
^iNGINEER FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES,
BE AT THE REQ
RNEY'S FEES ARISING OUT OF OR RESULTING THEREFROM.
HARMLESS TW-
IKIf l I InlMr. AT
1+00
PROPOSED GROUND
0
Y
LO
COMPACTED FILL Q
U)
IRRIGATION
SYSTEM
INTAKE
(APPROXIMATE)
1.0'
HEADWALL
6 PIPE DITCH AND
b FILL IN AREA
1
REMOVE AND REPLACE
EXISTING SEAWALL
0 STA: 2+51.30 (5.21' LT)
/ O
O
06 �
60" CMP
I V=
13.14
LO
STA: 2+51.30
INV. 13.14
REMOVE AND DISCARD
6 35 L.F. 60" CMP
b VREMOVE AND REPLACE
1k
EXISTING SEAWALL
STA: 2+51.30 (5.21' RT)
INSTALL 120 L.F.
52"x77" CMP
V WITNESS
IRRIGATION
SYSTEM
INTAKE
(APPROXIMATE)
zz::3- 1.0'
HEADWALL
EXISTING CANAL
EXISTING 43"X70" RCP
TO BE REMOVED
FOOT TYPE I
JUNCTION BOX
48 HOURS BEFORE DIGGING
CALL TOLL FREE
1-800-432-4770
SUNSHINE STATE ONE CALL
OF FLORIDA, INC.
REVISIONS DRAWING INFORMATION
NO. DATE
1. 06-11-•; FILENAME: GEORGE ST DITCH
BY DESCRIPTION
a MDS RESPONSE TO SJRWMD RAI DATED 05-06-09 SCALE: I"= 10"
SURVEYED BY: HSBS
DSGN: FTW DATE: 04-17--09
DRWN: MDS DATE: 06-11-09
CHKD: LGM DATE: 06-15-09
QAIQC: FTW DATE: 06-15-09
2+00
V
COMPACTED FILL
1:10 HORIZONTAL
1:5 VERTICAL
EXISTING CANAL
North
Report of Survey: (Ditch) GRAPHIC SCALE
05
* TYPE OF SURVEY: TOPOGRAPHIC I I 10
* THIS SURVEY PERFORMED BY:
E
HOUSTON, SCHULKE, BITTLE & STODDARD, INC. L.B. #6905 E
1717 INDIAN RIVER BLVD, SUITE 101 1 inch( IN FEET) 10 ft.
VERO BEACH, FLORIDA
32960
* PROFESSIONAL SURVEYOR & MAPPER IN RESPONSIBLE CHARGE:
STUART A. HOUSTON, P.L.S. #4490
THE EXPECTED USE OF
THE LAND AS
CLASSIFIED IN THE MINIMUM
TECHNICAL STANDARDS (61C17-6, FAC) IS SUBURBAN. THE MINIMUM
RELATIVE ACCURACY FOR THIS TYPE OF BOUNDARY SURVEY IS 1 FOOT
IN 7,500. THE MEASUREMENT AND CALCULATION OF A CLOSED
GEOMETRIC FIGURE WAS FOUND TO BE IN EXCESS OF THIS ACCURACY
REQUIREMENT.
* THIS SURVEY MEETS OR EXCEEDS ALL APPLICABLE REQUIREMENTS OF
THE MINIMUM TECHNICAL STANDARDS, AS ESTABLISHED IN CHAPTER
61617 6, FLORIDA ADMINISTRATIVE CODE.
* ELEVATIONS AND DIMENSIONS SHOWN HEREON ARE MEASURED IN FEET
AND DECIMAL PARTS THEREOF.
* THE LAST DATE OF FIELD WORK WAS: 9/30/08
* THE BEARING BASE FOR THIS SURVEY IS: N00°04'45"W, ASSUMED ALONG
THE CLOF GEORGE STREET, PER THE PLAT, AND SHOWN THEREON.
(NOTE: GEORGE STREET IS PLATTED AS "LANDSDOWNE DRIVE".)
* THIS SURVEY DOES NOT CERTIFY TO THE EXISTENCE OR LOCATION OF ANY
UNDERGROUND IMPROVEMENTS: UTILITIES, FOUNDATIONS, OR ENCROACHMENTS,
EXCEPT AS SHOWN.
* NO INSTRUMENTS OF RECORD REGARDING EASEMENTS, RIGHT -OF -WA -YS, ----
OR OWNERSHIP WERE SUPPLIED TO THIS SURVEYOR, EXCEPT AS SHOWN.
* NO TITLE OPINION OR GUARANTEE IS EXPRESSED OR IMPLIED.
* UNLESS A COMPARISON IS SHOWN, PLAT VALUES AND MEASURED VALUES
ARE THE SAME.
* LEGAL DESCRIPTION IS AS PROVIDED BY THE CLIENT.
* THE PARCEL OF LAND SHOWN HEREON APPEARS TO BE IN FLOOD ZONE 'X'
PER FLOOD INSURANCE RATE MAP #12061 CO078 E, DATED MAY 4th., 1989
* THE ELEVATIONS SHOWN HEREON ARE NGVD '29, AND ARE BASED ON A CLOSED
BENCH CIRCUIT TO A F.I.R.M. BENCHMARK. (REFERENCE MARK 26, F.I.R.M. PANEL
0078, - CHISELED SQUARE ON THE SOUTHWEST CORNER OF ENGLAR AVE. BRIDGE
OVER COLLIER WATERWAY, ELEV.= 25.07) ra TYPE: TO O hiC
ON-SITE BENCHMARK AS SHOWN. I� g P
Legenc & Abbreviations: (symbols not scaleable for size) PROJECT# Ditch
_ PLS - PROFESSIONAL LAND SURVEYOR `0- - WOOD UTILITY POLE OA TE: 9030008
PSM - PROFESSIONAL SURVEYOR & MAPPER ® - TELEPHONE SERVICE -
LB - LAND SURVEYING BUSINESS ® - CABLE T.V. BOX
0 - CENTERLINE ® - ELECTRIC BOX DRA WN B Y.• S.A.H.
E/P - EDGE OF PAVEMENT OO - WELL
B. M. - - BENCHMARK ® - WATER METER CHECKED BY:
O - IRON ROD & CAP LB 6905 ED. ® - SEPTIC TANK
FD - FOUND - MITERED END SECTION (MES)
(P) - PLAT VALUE - DRAINAGE SCALE: 1 -10
(M) - MEASURED VALUE MB - MAIL BOX
F_ F. - FINISH FLOOR CHIT - OVERHEAD ELECTRIC
THIS SURVEY IS NOT VALID
Lfoo CABBAGE PALM - OAK - CITRUS I v -
LEGEND
SURFACE WATER IMPACT (Area = 0.08 Ac)
REMOVE EXISTING CABBAGE PALM
��- PROPOSED SILT FENCE
EXISTING PAVEMENT TO BE REMOVED AND REPLACED
BY STRUCTURAL CONCRETE CAP (FROM TOP OF PIPE -
EXISTING ROAD ELEVATION).
_...-._ NOTES:
----_-- --- - -- 1. NO MITIGATION IS REQUIRED FOR THE IMPACTS TO UPLAND EXCAVATED DITCHES.
PLAT OF SURVEY FOR: CITY of
A TOPOGRAPHIC SURVEY OF A PORTION OF THE 30'
EXISTING 60" CMP EXISTING SEAWALL SE13ASTj DRAINAGE R/W ABUTTING LOTS 42 & 43, BLOCK 176,
SEBASTIAN HIGHLANDS UNIT 8, AS SHOWN ON THE
TO BE REMOVED µ PLAT THEREOF, RECORDED IN PLAT BOOK 6, PAGE 13,
OF THE PUBLIC RECORDS OF INDIAN RIVER COUNTY,
FLORIDA.
HOME OF PELICAN ISLAND
REVISIONS
®�1 PROFESSIONAL LAND SURVEYORS & MAPPERS
CERTIFICATEOFAMHORIZATION: LB 6905
D � 1717RVDI4NRIVERBLVD, -SUITE 101
D �I VEROBEACHFL. 32960
PH.: (772) 794-1213 FAX: (772) 794-1096
EMA/L:Z6945@bdsout6.not
NEEL=SCHAFFER
SOLUTIONS YOU CAN BUILD UPON
1201 19th Place, Suite A-100 Vero Beach,
Florida 32960 PH: (772) 770-4707
FAX: (772) 770-4640 CA00008556
TYPE: Topographic
PROJECT"# Ditch
DATE: 9/30/08 F.8. PG.
DRAWN BY.. S.A.H.
CHECKED BY..
SCALE: 1"=10' SHEET: 1 of 1
THIS SURVEY IS NOT VALID WITHOUT THE SIGNATURE AND THE
ORIGINAL RAISED SEAL OF THE FLORIDA LICENSED SURVEYOR
AND MAPPER NAMED BELOW.
N0. DATE DESCRIPTION BY .���nni r. nvv,�iviv, r,�-,�,�r•-r,7v
WORKING NUMBER:
EXISTING CONDITIONS AND PROPOSED IMPROVEMENTS NS.07000.001
GEORGE STREET DITCH
SHEET NUMBER:
SEBASTIAN, INDIAN RIVER COUNTY, FLORIDA
FRANK T. WATANABE, P.E. C-3
FL. REG. NO. 66735
-
..............I
_
_...
....
'
...............................-
_.
I
-
-
-
--
:
--
EXISTING 43"X70" RCP
TO BE REMOVED
FOOT TYPE I
JUNCTION BOX
48 HOURS BEFORE DIGGING
CALL TOLL FREE
1-800-432-4770
SUNSHINE STATE ONE CALL
OF FLORIDA, INC.
REVISIONS DRAWING INFORMATION
NO. DATE
1. 06-11-•; FILENAME: GEORGE ST DITCH
BY DESCRIPTION
a MDS RESPONSE TO SJRWMD RAI DATED 05-06-09 SCALE: I"= 10"
SURVEYED BY: HSBS
DSGN: FTW DATE: 04-17--09
DRWN: MDS DATE: 06-11-09
CHKD: LGM DATE: 06-15-09
QAIQC: FTW DATE: 06-15-09
2+00
V
COMPACTED FILL
1:10 HORIZONTAL
1:5 VERTICAL
EXISTING CANAL
North
Report of Survey: (Ditch) GRAPHIC SCALE
05
* TYPE OF SURVEY: TOPOGRAPHIC I I 10
* THIS SURVEY PERFORMED BY:
E
HOUSTON, SCHULKE, BITTLE & STODDARD, INC. L.B. #6905 E
1717 INDIAN RIVER BLVD, SUITE 101 1 inch( IN FEET) 10 ft.
VERO BEACH, FLORIDA
32960
* PROFESSIONAL SURVEYOR & MAPPER IN RESPONSIBLE CHARGE:
STUART A. HOUSTON, P.L.S. #4490
THE EXPECTED USE OF
THE LAND AS
CLASSIFIED IN THE MINIMUM
TECHNICAL STANDARDS (61C17-6, FAC) IS SUBURBAN. THE MINIMUM
RELATIVE ACCURACY FOR THIS TYPE OF BOUNDARY SURVEY IS 1 FOOT
IN 7,500. THE MEASUREMENT AND CALCULATION OF A CLOSED
GEOMETRIC FIGURE WAS FOUND TO BE IN EXCESS OF THIS ACCURACY
REQUIREMENT.
* THIS SURVEY MEETS OR EXCEEDS ALL APPLICABLE REQUIREMENTS OF
THE MINIMUM TECHNICAL STANDARDS, AS ESTABLISHED IN CHAPTER
61617 6, FLORIDA ADMINISTRATIVE CODE.
* ELEVATIONS AND DIMENSIONS SHOWN HEREON ARE MEASURED IN FEET
AND DECIMAL PARTS THEREOF.
* THE LAST DATE OF FIELD WORK WAS: 9/30/08
* THE BEARING BASE FOR THIS SURVEY IS: N00°04'45"W, ASSUMED ALONG
THE CLOF GEORGE STREET, PER THE PLAT, AND SHOWN THEREON.
(NOTE: GEORGE STREET IS PLATTED AS "LANDSDOWNE DRIVE".)
* THIS SURVEY DOES NOT CERTIFY TO THE EXISTENCE OR LOCATION OF ANY
UNDERGROUND IMPROVEMENTS: UTILITIES, FOUNDATIONS, OR ENCROACHMENTS,
EXCEPT AS SHOWN.
* NO INSTRUMENTS OF RECORD REGARDING EASEMENTS, RIGHT -OF -WA -YS, ----
OR OWNERSHIP WERE SUPPLIED TO THIS SURVEYOR, EXCEPT AS SHOWN.
* NO TITLE OPINION OR GUARANTEE IS EXPRESSED OR IMPLIED.
* UNLESS A COMPARISON IS SHOWN, PLAT VALUES AND MEASURED VALUES
ARE THE SAME.
* LEGAL DESCRIPTION IS AS PROVIDED BY THE CLIENT.
* THE PARCEL OF LAND SHOWN HEREON APPEARS TO BE IN FLOOD ZONE 'X'
PER FLOOD INSURANCE RATE MAP #12061 CO078 E, DATED MAY 4th., 1989
* THE ELEVATIONS SHOWN HEREON ARE NGVD '29, AND ARE BASED ON A CLOSED
BENCH CIRCUIT TO A F.I.R.M. BENCHMARK. (REFERENCE MARK 26, F.I.R.M. PANEL
0078, - CHISELED SQUARE ON THE SOUTHWEST CORNER OF ENGLAR AVE. BRIDGE
OVER COLLIER WATERWAY, ELEV.= 25.07) ra TYPE: TO O hiC
ON-SITE BENCHMARK AS SHOWN. I� g P
Legenc & Abbreviations: (symbols not scaleable for size) PROJECT# Ditch
_ PLS - PROFESSIONAL LAND SURVEYOR `0- - WOOD UTILITY POLE OA TE: 9030008
PSM - PROFESSIONAL SURVEYOR & MAPPER ® - TELEPHONE SERVICE -
LB - LAND SURVEYING BUSINESS ® - CABLE T.V. BOX
0 - CENTERLINE ® - ELECTRIC BOX DRA WN B Y.• S.A.H.
E/P - EDGE OF PAVEMENT OO - WELL
B. M. - - BENCHMARK ® - WATER METER CHECKED BY:
O - IRON ROD & CAP LB 6905 ED. ® - SEPTIC TANK
FD - FOUND - MITERED END SECTION (MES)
(P) - PLAT VALUE - DRAINAGE SCALE: 1 -10
(M) - MEASURED VALUE MB - MAIL BOX
F_ F. - FINISH FLOOR CHIT - OVERHEAD ELECTRIC
THIS SURVEY IS NOT VALID
Lfoo CABBAGE PALM - OAK - CITRUS I v -
LEGEND
SURFACE WATER IMPACT (Area = 0.08 Ac)
REMOVE EXISTING CABBAGE PALM
��- PROPOSED SILT FENCE
EXISTING PAVEMENT TO BE REMOVED AND REPLACED
BY STRUCTURAL CONCRETE CAP (FROM TOP OF PIPE -
EXISTING ROAD ELEVATION).
_...-._ NOTES:
----_-- --- - -- 1. NO MITIGATION IS REQUIRED FOR THE IMPACTS TO UPLAND EXCAVATED DITCHES.
PLAT OF SURVEY FOR: CITY of
A TOPOGRAPHIC SURVEY OF A PORTION OF THE 30'
EXISTING 60" CMP EXISTING SEAWALL SE13ASTj DRAINAGE R/W ABUTTING LOTS 42 & 43, BLOCK 176,
SEBASTIAN HIGHLANDS UNIT 8, AS SHOWN ON THE
TO BE REMOVED µ PLAT THEREOF, RECORDED IN PLAT BOOK 6, PAGE 13,
OF THE PUBLIC RECORDS OF INDIAN RIVER COUNTY,
FLORIDA.
HOME OF PELICAN ISLAND
REVISIONS
®�1 PROFESSIONAL LAND SURVEYORS & MAPPERS
CERTIFICATEOFAMHORIZATION: LB 6905
D � 1717RVDI4NRIVERBLVD, -SUITE 101
D �I VEROBEACHFL. 32960
PH.: (772) 794-1213 FAX: (772) 794-1096
EMA/L:Z6945@bdsout6.not
NEEL=SCHAFFER
SOLUTIONS YOU CAN BUILD UPON
1201 19th Place, Suite A-100 Vero Beach,
Florida 32960 PH: (772) 770-4707
FAX: (772) 770-4640 CA00008556
TYPE: Topographic
PROJECT"# Ditch
DATE: 9/30/08 F.8. PG.
DRAWN BY.. S.A.H.
CHECKED BY..
SCALE: 1"=10' SHEET: 1 of 1
THIS SURVEY IS NOT VALID WITHOUT THE SIGNATURE AND THE
ORIGINAL RAISED SEAL OF THE FLORIDA LICENSED SURVEYOR
AND MAPPER NAMED BELOW.
N0. DATE DESCRIPTION BY .���nni r. nvv,�iviv, r,�-,�,�r•-r,7v
WORKING NUMBER:
EXISTING CONDITIONS AND PROPOSED IMPROVEMENTS NS.07000.001
GEORGE STREET DITCH
SHEET NUMBER:
SEBASTIAN, INDIAN RIVER COUNTY, FLORIDA
FRANK T. WATANABE, P.E. C-3
FL. REG. NO. 66735
UNIFORM CROSS SLOPE TO MATCH
EXISTING AND UNIFORM GRADE PARALLEL
TO ROADWAY TO MATCH ELEVATIONS
AT LIMITS OF WORK
REMOVE EXISTING
PAVEMENT
SAWCUT EXISTING PAVEMENT
TO FORM A SMOOTH AND
STRAIGHT JOINT MATCH NEW
PAVEMENT TO EXISTING
12"
a,
REMOVE EXISTING BACKFILL MATERIAL
AND GRADE UNIFORMLY TO RECIEVE
12" MIN. THICK COQUINA BASE COMPACTED
TO 100% OF MAXIMUM DRY DENSITY AASHTO
T-180
EXISTING PAVEMENT
MATCH EXISTING PAVEMENT
THICKNESS OR CONSTRUCT 1-Y2"
MIN. COMPACTED THICKNESS D.O.T.
TYPE SP -12.5 ASPHALTIC CONCRETE
SURFACE; PRIME COAT ALL SURFACES
AND EDGES PRIOR TO SURFACING
1" MINIMUM TYPE SP-9.5(2ND LIFT)
� ► ► •moi ► •moi I
NEW PAVEMENT
01 SAW CUT AND BUTT JOINT
CD -1 SCALE: N.T.S.
I Type A Or B Riser
2 Additional Bars A
0 5" 0. C. #5 Hoop Bar
Perpendicular Bars A
(See Section AA -A) #4 Hoop Bar
L
2-# 7's Each W + ���0 \ Reference Axis
Placed On TOP 0 a 1
Bars A And B At 45'
Parallel Bars B (See Section A-
TOP SLAB REINFORCING STEEL DIAGRAM
U
a` r°a-
Ed me o
�W co 2
a�
ov p� �m #4012"BW
c x o (Horizontal Bars
c°0m N e o ars A 3p�6" 6. Continuous Around
o �" h Corners For m
,.0 t 4-0" Rectangular Riser's;°
v
2 -Extra # 4's N
a 0Each Side And
o m 8" ars B i Above Opening c
cy
Od U f] O
O
u- -ot-a #4' ® 12" O.C.
c o Each Way
N
w
m
c
o o:
0 c
12"
1
r^^^.■III■■MI
- - I.rr..■■_III■_NMI
It■�il��1116'-
■■■■■■Il;�
■■ OWN ■li
1 1/2" MINIMUM TYPE SP -12.5
COQUINA BASE 8" MINIMUM
THICKNESS COMPACTED TO 98%
OF MAXIMUM DENSITY PER AASHTO.
12" STABILIZED SUBGRADE (FBV 50)
(98% COMPACTION AASHTO T-180)
FILL COMPACTED TO
98% MAX/ DENSITY
2- #5 Hoop Bars
(2 Lap Splices Permitted)
-- J
2 Additional Bars A
®5"O. C.
Bars B Long Wayy
(See Section B -B)
TOP SLAB REINFORCING STEEL DIAGRAM
3'-6" (Typ.)
n Bars
0
� Bars B,
V)
E d
o cy
o ua
m F �
#4 0 12" BW
(Horizontal Bars
Continuous Around
Corners For
Rectangular Risers)
/ertical Wall Reinforcing
? o`
;See Table)
N
`......
SECTION C -C
O
Horizontal Wall Reinforcing
c
(See Table)
a s
-
m
F° c
Top Slab Reinforcin
m
Supplemental Bar A Or B
c
m
c
o v
`......
SECTION C -C
AT TOP SLAB
p
cn �c T
o ALTERNATE 8
3'
r
;.x„ Optional Shear Ke 1
Wall Reinforcin
oN
Shear Key
10' Draf
NOTE: Variations in shear key dimensions
not more than 1'-6" larger than the opening In
will be permitted subject to the
at 3" maximum spacing equal to half the area of vertical
Engineers approval.
10' Dra
reinforcment removed by the opening and provide the
1�
or riser shall be constructed according to the
.�.'ea' r.9 _'/
3}'
r I Optional Shear Ked
m—
m
�
'Special Top Slab" details on this sheet.
TTI
a
o
E: -:.U. S_AB
p
Bottom Slab Reinforcin
SLAB TO WALL DETAILS FOR PRECAST ALTERNATE WITH W WALLS
#4 Iles ® 12 O.C.
#5 Peripheral
Reinforcement
Wall Reinforcing
9- # 4 Ties ® 12" O.C. Rotate* 4 Bars As Required
(See Section) To Maintain Cover
#5
ReinforcemenPeripheral
t
L
m^
Bars A Bars B
�^
Bars A— Bars B
`......
SECTION C -C
c
�
ALTERNATE A
o ALTERNATE 8
SECTION A -A
�
� SECTION 8-8
SPECIAL TOP SLAB'
oN
• NOTE: When the inside diameter of a round structure is
NOTE: Provide extra reinforcing each side of each opening
N"
not more than 1'-6" larger than the opening In
at 3" maximum spacing equal to half the area of vertical
the riser or top slab, the top of the structure
reinforcment removed by the opening and provide the
or riser shall be constructed according to the
same area of reinforcment above each opening at 3"
'Special Top Slab" details on this sheet.
maximum spacing as removed by the opening.
GENERAL NOTES
1. Standard structure bottoms 4'-0" diameter and smaller (Alt. A) and 3'-6" 4.
Structure bottoms may be used in conjunction with curb inlet 10.
The corner fillets shown are necessary for rectangular structures used with circular
square (Alt. B) are designated Type P. Larger standard structure bottoms
tops Types 1, 2, 3, 4, 5, 5, 9, and 10, and any manhole or Junction box unless
otherwise shown in the or other standard drawings. Alt. B structure
risers and Inlet throats and used on skew with rectangular risers, inlet and inlet
throats. Fillets will be required in lieu of the bottom slab of the Alt. B riser when
are designated Type J. Risers are permitted for all structures.
plans
bottoms may be used in conjunction with curb inlet Types 7 & 8, or
used with the Alt. A box. Each fillet shall be reinforced with 2-#5 bars.
2. Walls of circular structures (Alternate A) constructed in place may be
any ditch bottom inlet unless otherwise shown in the plans or other standard
of non -reinforced concrete or brick or reinforced concrete. Precast and
drawings.
11.
Inlet throats, riser or manhole tops shall be secured to structures as shown on
rectangular structures (Alternate B) shall be constructed of reinforced
Index No. 201.
concrete only. 7.
Rectangular structures may be rotated as directed by the Engineer to order
3. Wall thickness and reinforcement are for either reinforced cast -In-place
to facilitate connections between the structure walls and storm sewer pipes.
12.
Structures with depths over 14' are to be checked for floatation by designer of
or precast concrete units except that precast circular units may be furnished
project drainage.
with walls in accordance with either A.S.T.M. C-478 (up to 96 diameter) 8
Except when ACI hooks are specifically required, reinforcement top and slab
or A.S.T.M. C-76, Class ---, B Wall, modified where the elliptical steel cage
shall be straight embedment. 13.
Units larger than specified standard may be substituted at the contractors optl,",
area is placed in the center one-third of the wall.
when these units will not cause or increase the severity of utility conflicts. Such
units shall be furnished at no additional cost to the Department. Larger STRUCTURE
BOTTOMS
4. Top and floor slab thickness and reinforcement are for precast and cast inlarger
construction. Top and floor slabs shall be of Class -- 9.
All steel bars shall hovb4' minimum cover unless otherwise shown except for
Alternate A units cannot replace Alternate Bunits without approval of the TYPE
AND
place
concrete. Concrete as specified in A.S.T.M. C-478 (4000 psi} may be
precast circular units manufactured under ASTM C-76 or ASTM C-478, Horizontal
Engineer. This note applies to this Index only.
used 1n lieu of Class - and Class -- concrete in precast items manufactured
steel in rectangclar structures shall be lapped a minimum of 24 bar diameters
at comers.
in plants which are under the 'Standard 0 erotin Procedures for the
p P 9
14.
For manhole and junction box tops, for frames and covers, and, for supplementcry
inspection of precast drainage products.
details see Index No. 201.
5. All reinforcement shall be A.S.T.M. A615, Grade 60 or 65 KSI welded wire
fabric, either smooth or deformed.
TYPE 'P' AND 'J' STRUCTURE BOTTOM
REFER TO FDOT INDEX NO. 200 NTS
03 TYPE 'P' AND IS STRUCTURE BOTTOM (FDOT INDEX 200
7
7
SCALE: N.T.S.
NOTICE TO DRAWING HOLDER
IESE DRAWINGS. IF ANY DISCREPANCIES OCCUR WITHIN THESE
CONTRACTOR SHALL CONTACT NEEL-SCHAFFER, INC. FOR
DO NOT SCALE I PRIOR TO CONSTRUCTION. NEEL-SCHAFFER, INC., HEREINAFTER
DOCUMENTS, Th!-. THE ENGINEER HAS PREPARED AND FURNISHED THIS DRAWING TO
CLARIFICATIONS USE ON THIS PROJECT ONLY. THIS DRAWING SHOULD NOT BE USED
REFERRED TO V )F THIS PROJECT OR ON ANY OTHER PROJECT, ANY REUSE OF THIS
THE OWNER Foe. JT VVRITTEN VERIFICATION OR ADAPTION BY THE ENGINEER, SHALL
ON EXTENSION
DRAWING, WITH' -.,RAS SOLE RISK AND THE REUSER SHALL INDEMNIFY AND HOLD
BE AT THE REU'' `mYS EES ARISING OU7AGINEER FROM ALL T OF OR RESULTS, DAMAGES, ING TH RESULTING SSES ERAND EXPENSES,
HARMLESS THE
oars I InWG ATS
48 HOURS BEFORE DIGGING
CALL TOLL FREE
1-800-432-4770
SUNSHINE STATE ONE CALL
OF FLORIDA, INC.
REVISIONS
N0. DATE
1. 06-11-C BY DESCRIPTION
MDS RESPONSE TO SJRWMD RAI DATED 05-06-09
DRAWING INFORMATION
FILENAME: GEORGE ST. DITCH
SCALE: 1"= 10'
SURVEYED BY: HSBS
DSGN:FTW DATE: 04-17--09
DRWN: MDS DATE: 06-11-09
CHKD: LGM DATE: 06-15-09
QAIQC: FTW DATE: 06-15-09
NEEL-SCHAFFER
SOLUTIONS YOU CAN BUILD UPON
1201 19th Place, Suite A-100 Vero Beach,
Florida 32960 PH: (772) 770-4707
FAX: (772) 770-4640 CA00008556
EXISTING BASE
NEW HOT PATCH ASPHALT TO BE SAME TYPE OF
MATERIAL AS EXISTED AT THE TIME OF REMOVAL.
EXISTING SURFACE AND BASE TO
BE CUT WITH CONCRETE SAW.
TRENCH WALL
UNDISTURBED EARTH
MAX MAX
NOTES:
REPLACEMENT BASE MATERIAL SHALL BE 3000
PSI HIGH EARLY STRENGTH CONCRETE.
BACKFILL TRENCH WITH SUITABLE MATERIAL AND TAMP
MATERIAL IN LAYERS NOT TO EXCEED 6" IN ACCORDANCE
W/ THE SPECIFICATIONS. (95% MAX. PER. AASHTO T-180).
THE CONTRACTOR SHALL PROMPTLY FILL OPEN -CUT TO ALLOW TRAFFIC
TO PASS FREELY AND SAFELY. IF PERMANENT RESTORATION IS TO BE DEFERRED.
THE CONTRACTOR SHALL MAINTAIN THE TEMPORARY CONDITION TO THE ORANGE
COUNTY ENGINEERING DEPARTMENT SATISFACTION.
02 ASPHALT ROADWAY OPEN CUT DETAIL
CD -1 SCALE: N.T.S. PAVED AREAS
MISCELLANEOUS DETAILS
GEORGE STREET DITCH
SEBASTIAN, INDIAN RIVER COUNTY, FLORIDA
FRANK T. WATANABE, P.E.
FL. REG. NO. 66735
WORKING NUMBER:
N .07000.001
SHEET NUMBER:
CD -1