June lb, 1990
Ms. Linda Kinchen
City of Sebastian
Engineering Department
P.O. Box 127
Sebastian, Florida 32958
lo-,
RE: Vickers Grove Subdi-vision Preliminary Plats Submittal
Dear Linda:
Please find attached herewith four (4) sets of the
following information in support of Dr. Henry A. Fischer's
application for preliminary plat approval for the above
referenced project.
1. Four (4) copies of the Vickers Grove Subdivision
Preliminary Plat.
2. Four (4) copies of the Vickers Grove Land Development
Plans.
The following is intended to be our tentitive response to
the request for additional information as stated in Mr. David
Fischer's letter dated February 26, 1990.
1. Traffic Impact Analysis and Study as required by the
City of Sebastian Land Development Ordinance is on going
at the present time. This impact study will be
transmitted to you upon its completion.
L. Calculations indicating recreational area requirements
for the proposed subdivision are attached for your review.
3. A copy of the letter requesting a ruling from the
Indian River County Health Department, with regard to
septic tank and drain fill aspects of the proposed
residential lots within the Vickers Grove Subdivision,
will be forwarded under separate cover. We expect a
response from the Health Department in the near future and
this information will be transmitted to you upon our
receipt.
Ms. Linda Kinchen
.June 18, 1990
Page 2
4. The public potable water system designed and depicted
on the land development plans has been submitted to Indian
River County Utility Department for their review and
approval. A copy of the Indian River County Utilities
Department permit will be submitted to the City of
Sebastian upon our receipt.
5. The Concord Street right-of-way dedication has been
delineated on the preliminary plat and land development
plans for the Vickers Grove Subdivision project.
Please do not hesitate to contact me if you have any
questions with any of the items outlined above or on any other
matter. Thank you for your assistance and cooperation.
Respectfully yours,
MASTELLER & MOLER ASSOCIATE;;, CNC.
Onley � hlayfie� '
Principal
SFM/mll
Encl:
File: #8933
cc: Dr. Henry A. Fischer
M
SINGLE FAMILY
43/D.U.
MULTI FAMILY
118/D.U.
RECREATION AREA CALCULATIONS
FOR VICKERS GROVE SUBDIVSION
AVERAGE
HOUSEHOLD SIZE
PER DWELLING UNIT
X 2.46
105.8
X 2.2
413.6
TOTAL
519.4
AVERAGE REQUIREMENT
PER DWELLING UNIT
X 0.0123 AC.
52 AC.
X 0.0110 AC.
1.2 AC.
TOTAL ACRES
1.72 AC.