Loading...
HomeMy WebLinkAbout1999 Water Assessment Project Phase 2D (Box 30 #11)0 RIVER )LINTY m cn Q m 0 l�v S� BAS --A\\ 2 D JL� s s 1 `V JL JL_I JL �' � � � � e� JL� C � JL 11 JL AS UW 97 13 nl-jS INDEX OF SHEETS o. 1. 1.2 2. 19. SHEET MASTER INDEX MASTER INDEX 18. PLANS 21. DETAILS COVER fEi 1E l L1J W .. �► P / A w co cm VICINITY MAP REVIEWED AND APPROVED BY: tE DEPT OF C WAT RAMP ►C[AL CENTEF BOAT RAMP .Deb w MICHAEL C. HOTCHKISS, FLA, P,E, 39514 i REMOVE EXISTING M.J, CAP AND CONNECT INSTALL TEMPORARY JUMPER -- " EXISTING 8' PVC. W,M SNEET 4 EXISTING 12' PVC. W.M REMOVE EXISTING M,J, CAP AND CONNECT INSTALL TEMPORARY JUMPER (SEE SHEET 4 OF 21 FOR CLARIFICATION) 0 �j MAU J REMOVE EXISTING M,J. CAP AND CONNECT INSTALL TEMPORARY JUMPER NOTEi ALL WATER MAINS ARE 6' DIAMETER UNLESS OTHERWISE NOTED, S,P _ DENOTES SAMPLE POINT LOCATION Revision I Date By No,l RevisionI Date By �c INDIAN RIVER COUNTY ' - 1840 25th STREET -�- . VERO BEACH, FIARIDA 32980 (407) 567-8000 DEPARTMENT OF UTILITY SERVICES s S Qu H d y- L LEI 0 SCALE, 1' = 300' f Maser Index Sheel 1 ` EXISTING 8' PVC, W,M REVIEWED AND APPROVED BY, MICHAEL C, HOTCHKISS, FLA, P,E, No, 39514 DATE, SEBASTIAN PHASE 2 D SHEET TECHNICALi BLANKEN JULY 99 SCALE 1` = 300' � DESIGNED BY. MICHAEL C. H❑TCHKISS I WATER ASSESSMENT PROJECT 1 APPROVED BY' COUNTY PROJECT NO, UW-97-13-DS OF 2 1 E Ln J SEE Master Index Sheet 1 C Sheet ll w rhm 11 Wll IS❑LATE TWO EXISTING VALVES v INSTALL 12' X 12' M,J, TEE & C❑NNECT ,y INSTALL TEMPORARY JUMPER nj �a (SEE SHEET 14 OF 21 r FOR CLARIFICATI❑N) -y5 RUPT 1¢ DIP, W,M (DRY) to be fleld located EXISTING 6' PVC, F,M EXISTING 12' PVC, W,M N❑TEi ALL PIPES ARE 6' DIAMETER UNLESS OTHERWISE NOTED. S,P - DENOTES SAMPLE PINT LOCATION ._v No, Revision Date By No, Revision Date By �EaINDIAN RIVER COUNTY 1840 25th STREET VERO HEACIJ FLORIDA 52980 �<oRi�P (407) 567-8000 DEPARTMENT OF TECHNICAL, BLANKEN DESIGNED BY, MICHAEL C. HOTCHKISS UTILITY SERVICES APPROVED BY, \ ;RANGE 38 EAST RANGE 39 EAST y fi O 4 SCALE, 1' = 300' N i I 1S NOS8i9 t U , 4r D O I O R1 __ C - Cp RANGE 38 EAST zo RANGE 39 EAST AVE LflUIS1PNA RAIL ASS C��S1 M U) EXISTING 8' PVC. W,M REMOVE CAP & CONNECT INSTALL TEMPORARY JUMPER (SEE SHEET 18 OF 21 FOR CLARIFICATION) Master Index Sheet Z REVIEWED AND APPROVED BY, MICHAEL C. HOTCHKISS, FLA. P,E. No, 39514 SHEET 1>ATE° JULY 99 { SEBASTIAN PHASE 2 D SCALE, V = 300' COUNTY PROJECT NO, UW-97-13-DS WATER ASSESSMENT PROJECT z 1 INSTALL M.J. BEND 1 1.25' INSTALL M.J. BEND 1 1.25' INSTALL 6" x 6".` M.J. TEE 6" M.J.G.' INSTALL M.J. BEND / INSTALL F.H.A -- INSTALL M.J. BEND 1 1.25' n INSTALL M.J. BEND 1 1.25' ''� INSTALL 6" x 6" M.J. TEE 6" M.J.G.V INSTALL M.J. BEND 1 1.25' CONST. 20 L.F-6" CL.350 DIP. W.M CENTERED, UNDER EXISTING STORM PIRE w/ 18" MIN. VERT. CLEARANCE (TYP.) — SEE DETAIL M-6 No,Revision I Date I By I Nod Revision Date By �Rc I I F--FR C FR E- EK INSTALL M.J. BEND / 1 1.25' Mob MATCHLINE SEE SHEET 3 NDIAN RIVER COUNTY 1840 25th STREET VERO BEACH, FIARIDA 32960 (407) 567-8000 CONST. 6" PVC. W.M AS SHOWN INSTALL F.H.A w/ `MIN. 36" COVER & RESTORE IN KIND. I N STALL 6" x 6" M.J. TEE 1 SIDEWALK BORE 6" PVC. W.M. UNDER CONC. DR. (TYP) 3' 0" MIN. INSTALL 45' M.J. BEND SCALE. 1' = 6 0' 14' + T 011 W O ASPNRLT INV. EL. 21.5 3' 0" MIN. EXISTING 12" DIP. W.M (DRY) 8 L. INSTALL.. 45 deg. (4) M.J. BENDS w/ RESTRAINT NORTH SIDE PER SPECIFICATIONS. Horizontal Scale: 1" = 10' Vertical Scale: 1" — 3' 20' + N- D_ C._R. S 1_ , ASPHALT_ - EXISTING 12" DIP. W.M SOUTH SIDE DITCH CROSSING C.R. 512 NEAR EASY STREET SOO C� 3' 0" MIN. EXISTING 6" PVC. F.M INV. EL. 1.9 0 10 18 •, 3' 0" MIN. MIN. 12" DIP. W.M. INSTALL 90' M.J. BEND GENERAL NOTES INSTALL SINGLE LENGTH 12" DIP. CENTERED UNDER EXISTING 6" ' PVC. F.M. WITH WITH MIN. 18" SEPERATION. INSTALL. 45 deg. (3) M.J. BENDS w/ RESTRAINT PER SPECIFICATIONS. 1. CROSSINGS MAY BE DRILLED & BORED OR DIRECTIONAL BORED USING H.D.P.E IN LIEU OF OPEN CUT. AT ALL LOCATIONS, WHERE ENTIRE INTERSECTION IS SPECIFIED TO BE OVERLAID WITH ASPHALT. PVC MAY BE UTILIZED AT ALL ROAD CROSSINGS, IN LIEU OF DIP PROVIDED 42" OF COVER IS MAINTAINED. 2. THERE ARE NO GRAVITY SEWER SYSTEMS IN VICINITY OF PROJECT. 3. ALL WATER SERVICE LOCATIONS SHALL BE DETERMINED BY CONTRACTOR; BASED ON CONFLICTS AND LAND OWNER'S REQUEST. 4. WATER SERVICES MAY BE USED TO OBTAIN TEMPORARY SAMPLES. 5. NO WATER IS TO BE SUPPLIED, UNTIL A LETTER OF CLEARANCE IS RECEIVED FROM F.D.E.P. 6. RESTRAINT SHALL BE PROVIDED AT ALL BENDS, VALVES, AND FrMNGS PER I.R.Co. STANDARDS. 7. LOCATION OF ALL EXISTING UTILITIES ARE APPROXIMATE ONLY, CONTRACTOR IS RESPONSIBLE FOR EXACT FIELD LOCATION. 8. ALL HARD SURFACE DRIVES TO BE DRILLED AND BORED. IF DRIVEWAY IS DAMAGED, OR CANNOT BE BORED, ENTIRE SECTION OF CONCRETE FROM CUT TO PAVEMENT SHALL BE REPLACED. 9. ALL EXISTING SIGNAGE SHALL BE RESTORED IN KIND. 10. FINAL GRADE OF RESTORATION SHALL BE 20 BELOW SODDED GRADE TO ALLOW FOR SOD DIFFERENTIAL. 11. ALL WATER FLUSHED FROM MAINS SHALL BE DIRECTED INTO REAR YARD DITCHES. FLUSHING INTO FRONT YARD SWALES IS FORBIDDEN BY THE CITY OF SEBASTIAN. 12. ONE ROW OF BAHIA SOD SHALL BE PLANTED AT EDGE OF ROAD, IF DISTURBED. 13. ALL DRIVEWAY AND ROAD CROSSINGS MAY BE DIRECTIONAL BORED USING H.D.P.E. ( IN LIEU OF DRILL & BORE OR OPEN CUT) & RESTORE IN KIND. 14. LOCATION OF GATE VALVES & FITTINGS SHALL BE ADJUSTED AS REQUIRED TO AVOID DISTURBANCE OF ROAD PAVEMENT. LOCATION ADJUSTMENTS SHALL BE MADE ONLY AFTER OBTAINING APPROVAL FROM THE ENGINEER OF RECORD. DATE, SEBASTIAN SHEET TECHNICAL, BLANKEN DULY 99 PHASE 2D SCALE: 1' = 60, DESIGNED BY, COUNTY PROJECT NO, UW-97-13 DS WATER ASSESSMENT PROJECT MICHAEL C. HOTCHKISS APPROVED BY, 21 OF CONST. 6" PVC. W.M. AS SHOWN w& RESTORE MIN. 36"IN COVER-,,, MATCHLINE SEE SHEET 5. + B I I 5' (TYP.) W O J_ CONST, 20 L.F-6' CL.350 DIP. W.M CENTERED ( 5' (TYP.) _ 5' (TYP) (? Lj U UNDER EXISTING ORM PIPE w 18" MIN. _.. , ....... _._. _ _ ._ _ _. Q W v� VERT. CLEARANCE (r' P.) - SEE DETAIL M-6 . - m to T LLJ BORE 6" PVC. W.M. INSTALL F.H.A UJI UNDER CONC. DR. TYP) i (n NJW � � BORE 6" PVC. W.N. �. ;�� OPEN CUT ASPHALT RD. UNDER CONC. DR. (TYP) W.- 100.00 i SAW.- 27.93 & RESTORE IN KIND. �.. CONST. 48 L.F. CL.350 DIP. i m I I INSTALL 6" x 6" (� INSTALL F.H.A (� I i — — M.J. TEE , 6" M.J.G.V I � I BORE 6" PVC. W.M. UNDER CONC. DR. (TYP) OPEN CUT ASPHALT RD. CONST. 6" PVC. W.M. Z INSTALL 6" x 6" & RESTORE IN KIND, AS SHOWN y M.J. TEE w/ MIN. 36" COVER 6 M.J.G.V CONST. 48 L.F. CL.350 DIP. i O & RESTORE IN KIND. _ f CONST. 6 PVC. W.M. AS SHOWN INSTALL F.H.A I wl MIN. 36 COVER & RESTORE IN KIND. I M cn f III � � a . ?I (� INSTALL F.H.A CONST. 6" PVC. W.M.:E l I CONST. 6" PVC. W.M. 5' (TYP.) AS SHOWN,,,-,- AS SHOWN � _ I w/ MIN. 36" COVER w/ MIN. 36" COVER & RESTORE IN KIND. & RESTORE IN KIND. 5 (TYP.) I INSTALL M.J. BEND NJW- 97a9 DIRECTIONAL BORE INSTALL F.H.A 1 Mr.- lmlo 6" W. M N.M.- 9&65 1 1.25' CL-, 1000o:is0 / NG,- 1TOP s 0D.W = 99.42 Nc.- too 0 CL- 101.09 DIRECTIONAL BORE Nw.- ioo.00 No. looao I (� ! N.W. - 913.08 „ S.9N.- TOP STRUCTURE= 99.81 � "' NMI._ 100.00 6 W . M S.91J - 9a94 CL- 100.00 M _.. .= 98.54 W _ Cl.- 100.28 XG• . NQ- 99.30 �+�J TOP SIRI�RJRE- .12 SM.- 97.47 e ZBORE 6" I PVC. W.M. B..S•U,G__ UNDER CONC. DR. (TYP) -_ r n . INSTALL M.J.- U22.5':17 BORE 6" PVC. W.M. UNDER CONC. DR. (TYP) / r,�/' DIRECTIONAL BORE INSTALL 6" x 6" INSTALL M.J. BEND INSTALL 6" x 6" �� / 11.25' M.J. TEE 6" W.M M.J. TEE, 6" M.J.G.V 6" M.J.G.V k`y INSTALL M.J. BEND 04 m /� �' 45' - 2' W CONST. 6" PVC W. I. BORE 6" PVC. W.M. �, .. N. l0000 -; UNDER CONC-. DR. (TYP) INSTALL 8 x 8 W. 9.OD AS SHOWN M.J. CROSS Nw.= l0000 __.. . c� 1oo.so / MIN. 36" COVER 8" x 6" M.J. REDUCER-(3) - ��+0 & RESTORE IN KIND. W Nw.9994 - O 6" M.J.G.V - 2 W S91Y - 97 = (%) I e::3 INSTALL G 1L 6' x 6 REMOVE 8" PLUG & CONNECT INSTALL TEMPORARY JUMPER Z �/ M.J. TEELE _ .' SEE DETAIL W-12 J 6 M.J.G.V i F- INSTALL M.J. BEND 22.5' DIRECTIONAL BORE i 6" W.M. ` INSTALL 6" x 6" M.J. TEE 6" M.J.G.V CONST. 20 L.F-6" CL.350 DIP. W.M CENTERED, UNDER EXISTING STORM PIPE w/ 18" MIN. VERT. CLEARANCE (TYP.) - SEE DETAIL M-6 i 0 DIRECTIONAL BORE 6" W.M DIRECTIONAL BORE 6" W.M INSTALL M.J. BEND SCALE: 1' = 60' No, Revision Date B No. Revision Date B pNEI� y y r INDIAN RIVER COUNTY DATE TECHNICAL, BLANKEN JULY 99 PHASE DEPARTMENT OFSEBASTIAN 2 DSHEET 1840 25th STREET VERID BEACK FWRWA 32960 407) W7-8000 _ - - SCALE, 1' = 60' 'DESIGNED BY, MICHAEL C. HOTCHKISS APPROVED BY UTILITY SERVICES WATER ASSESSMENT PROJECT 1 2 CQRI� COUNTY PROJECT N0, UW-97-13-DS OF li INSTALL W.J. BEND 90, REMOVE 8" PLUG 8c CONNECT INSTALL TEMPORARY JUMPER .� SEE DETAIL VV-1 2 � ^ MCHLINE SEE SHEET _6 11.07 VERT. C CE (TYP.) — SEE BUAJL M* 6 W-W'- 9&41 CONST. 20 L.IG' CL.350 DIP. W.M CENTERED, INS'TALL M.J.'BEN 1�1_ t 11 � � : i2o. a'o" UNDER EXISTING PTORM PIPE w/ 18* MIN. 45* \ .4. VERT. CLEARANC (TYP.) — SEE DETAJL M-6 UNDER CONC. . (T`/P) D \ U | . W.M. BORE ^ - AS SHOWN ; ' | - --'--'--�- UNDER [�O��C DR [7/P) = U] ' " y MIN. 36° COVER �� | | - - - -- �� RESTORE IN KIND. -UNDER^��'`°' ""'�''' / - | Q / '~ ,. SHOWN DIRECTIONAL BORE p ` ` k�|N. 38" COVER ~ yy.k� � |NSTALL F H�--� � | ' RESTORE IN KIND. v/ /TYP\ -- ~ `� .� ./ v' " � r� CONS[ 4 PVC. W.M. ` ` AS SHOWN K4|N� J8" COVER vv' � - / | |\ 6b RESTORE IN KIND. / �. m--��U | | � | | \/� ��U|�� | / V ��|- � °.�-----' - - ' --- 7\ -=".. . .. �(� =,8"x 8"k4J TEE �u - ` | � ^^ x"a°~�� W.J. REDUCER _ 2 5' (T`(p.1 ^ O" �W.J.G)/ - 2 WJW' / ^ �����~ y 8| | CONST' G" ' �VC VVW� ' ' oL~mu� AS __.-. �99.80 q I I CONST. 6" PVC. VV.M.~- AS SHOWN w/ MIN. 30" COVER & RESTORE IN KIND. OPEN CUT ASPHALT RD. & RESTORE IN KIND. C0NST. 20 LF-8" CL.350 DIP W.M CENTERED, UNDER EXISTING STORM PIPE w/ 18~ MIN.~~� Vi . VERT. CLEARANCE (TYP.) - GEE DETAIL M-5 0 OPEN CUT ASPHALT RD. C6 C6 r � DRECTONAL BORE ` INSTALL O, x 6, INSTALL F.H.A -- | F:R E- ` �-' ~ \ WJ ' TEE O� k4J.G)/ 4" ' `INSTALL F " "___\ " INSTALL � x 5 0U � \ , , ~` ` B�RE � PVC. W.M. M.J. TEE ^u \ \ 4" k�^].(�,V ` INSTALL �� x M UNDER CONC. DR. (TyP) 6° W.J.{�.V ` M.J. TEE�� ' ~�~ �" �.J.�.� \ ?~|NSTALL k4.J. BEND / ' 22.5*MG.- 10020 � / u \ 80 . || ' ���� | /----1 /^--` L^�- ���� -'~l ~^ ~~. �---/ �---``--~' `�_-� r .` �__/ ___,_� ." B.3UG un . . - � ' 5' (TYP] \ �� �^ C]NST_ 8" PVC. W.M. � � AS SHOWN CIO 6" W. M BORE 6" PVC. W.M. RESTORE IN KIND. INSTALL 6" x 6" UNDER CONC. DR. (TYP) M.J. CROSS OPEN CUT ASPHALT RD. CONST. 6" PVC. W.M. & RESTORE tN KIND. AS SHOWN CONST, 48 L.F. CL.350 DIP. RESTORE IN KIND. DIRECTIONAL BORE TOP GRATE- 99.94 ui M.J. TEE DIRECTIONAL B , ORE REMOVE 12" PLUG & CONNECT INSTALL TEMPORARY JUMPER M �JBEND INSTALL M.J. BEND (12 CULVERT BRADGE DIRECTIONAL BORE *Ilk M,J. TEE HEADWALL 12" W.M \INSTALL. F. H.A CONST. 12" PVC. W'M. OPEN CUT DRIVEWAY & RESTORE IN KIND 6" M.J.G.V INSTALL M.J. BEND INSTALL 45' M.J� BEND AS SHOWN INSTALL 6" M.J.G.V N LIEU OF OPEN CUT RESTORE IN KIND, & RESTORE IN KIND. CONTRACTOR MAY DRILL BORE UNDER DRIVEWAY INSTALL 45* M.J� BEND DIRECTIONAL BORE MATCRUNE SEE SHEET 2 DATEi SHEET No, Revision Date By No, Revision Dcte Byl DEPARTMENT OF TECHNICALi BLANKEN JULY 99 INDIAN RIVER COUNTY SEBASTIAN PHASE 2 D 4 APPROVED BYf PROJECT NO. UW-97-13—DS (407) 567-8000 UTILITY SERVICES C12UNTY WATER ASSESSMENT PROJECT_OF 21 5' (TYP.) INSTALL F.I I ' , rn 5 (TYP.) — 5 (TYP.) I D rri 5' (TYP.) BORE 6" PVC. W.M. 0 m UNDER CONIC. DR. (TYP) vi r _ m 5 (TYP.) - m z I i i CONST. 12" PVC. W.M. —+ I i A w/ MIN. 36" COVER & RESTORE IN KIND. _ PALM i INSTALL F.H.A " INSTALL F.H.A INSTALL 12 x 6 INSTALL F.H.A M.J. TEE 6" M.J.G.V i I I INSTALL F.H.A �II �I I _ I i I CONST. 20 L.F-6" CL.350 DIP. W.M CENTERED, UNDER EYtST!,yG STORM PIPE :;,/ 1 R" M!nI; I i I VERT. CLEARANCE (TYP.) — SEE DETAIL M-6 y • r , . � I ` I � � sI y 300 U 20u N0- ,00.00cL-00.68 w.NO.-,00.40 100.0' vI I,�-00.00 00.07 -, EJW_9as N � il � J—_ -"`--- _ `CONST. 6" PVC. W.M. I ( CONST_ PVC., 6 W.M. , ONST. 6" PVC. W.M. m Ago AS SHOWN AS SHOWN- S SHOWN m w/ MIN. 313 COVER w/ MIN. 36" COVER w MIN. 36" COVER & RESTORE' IN KIND. i I & RESSTORE IN KIND. / T I i r_z & RESTORE N KIND. _ r� i \�\ BORE 6" PVC. W.M. I ! 0 I I BORE PVC. W.M. I ( ( I I I in UNDER CONC. DR. (TYP)CONST. 20 L.F-6 CL.350 DIP. W.M CENTERED, wlw- Qs UNDER CONC. DR. (TYP) UNDER EXISTING STORM PIPE w/ 18" MIN. I — W.- 99,90 IMG.- 100 0 VERT. CLEARANCE (TYP,) — SEE DETAIL M-6 I n/ +w cl- ,ao.eo ►rr.- 100.00 i , I EJW- - 95. j OPEN CUT ASPHALT RD. OPEN CUT ASPHALT RD. ! L I I & RESTORE: IN KIND. , '~ INSTALL F.H.A , I DIRECTIO CONST. 48 L.F. CL.350 DIP. -0 & RESTORE IN KIND. 1 12" W.M CONST. 48 L.F. CL.350 DIP. MJ i i I � B. I CONST. 12" PVC. W.M. _ B,S.U. t AS SHOWN — -- -- INSTALL 6" x 6" w/ MIN. 36" COVER i HI M.J. TEE & RESTORE IN KIND. -- --- _--- -_i--- _ --- 6„. M.J.G.V EE-: L— L - I (mil C�; !E-; E-- I\I LJ N „ N.W.- 97.2E >, CONST. 6 PVC. W.M. 1 5 ALL 6 x 6 W.. ,00.19 INSTALL 6 x 6 INSTALL 6" x 6" W.- 100.00 AS `SHOWN M.J. TEE M.J. TEE M.J.? TEE w--- io°osso " w MIN. 36" COVER 6" M.J.G.V 6 M.J.G.V SJW ,00ao 6 M.J.G.V &/RESTORE IN KIND. Li INSTALL F.H.A C::) C B.S.U.G I iI BORE 12" PVC. W.M. W 1 ) UNDER CONC. DR. (TYP) i V) OFEN CUT DRIVEWAY & RESTORE IN KIND I � ± � I W CONST. 12" PVC. W.M (TYP.) DIRECI 7 IN LIEU OF OPEN CUT & RESTORE IN ,KIND, I 12" W J / CCNTRACTOR MAY GRILL & BORE UNDER DRIVEWAY U `i - I ! INSTALL F- E 45' M.J. BEND (2) DIP 6" M.J.G.V. I 12' OPEN CUT ASPHALT RD, OPEN CUT ASPHAL'� RD. W i0 3 & RESTORE IN KIND. 0.00 &RESTORE IN KIND. ''10- 100°° �-- �� CONST. 48 'LF. CL.350 DiP.': j DIRECTIONAL BORE CL-,00 s CrONST. 48 L.F. CL.350 DIP. 6" W.M w- 9999M - S.W.- 9529 ra t 4 . _"V""M . _ B.S.U.G, ry INSTALL 12 x 6" M J CROSS INSTALL 12" x 12" DIRECTIONAL BORE 6" W.M. AVE OPEN CUT DRIVEWAY & RESTORE IN KIND CONST. 12" PVC. W.M (TYP.) IN LIEU OF OPEN CUT & RESTORE IN KIND, CONTRACTOR MAY DRILL & BORE UNDER DRIVEWAY NAL BORE ZONAL BORE M. ECTIQNAL BORE W.M (2 PLACES) e)r SCALE, 1' = 60" W I INSTALL F.H.A INSTALL 12" M.J. CRASS x 6" M.J TEE (y- CONST. 12" PVC. W.M. ( 12" M.J.P.V. 6" M.J.G.V F- AS SHOWN „ „ INSTALL 12" M.J.P.V 45' M.J. BEND (2) / MIN. 36" COVER INSTALL 12 x 6 M.J TEE INSTALL 12 x 6' n }- & RESTORE IN KIND, 6" M.J.G.V INSTALL F.H.A 45' M J. BEND (2) " Q 45- M.J. BEND (2) 6 M.J.G.V. M.J REDUCER M V. 6 .J G. INSTALL F.H.A MATCHLINH. - • I No, I Revision F- Date By I No,l Revision NDIAN RIVER COUNTY DEPARTMENT OF 1840 25th STREET VERO BEACH, FIDRIDA 32960 (407) 567-8000 UTILITY SERVICES DATE,. TECHNICAL+ BLANKEN DULY 99 SEBASTIAN PHASE 2 Vn 5 SHEET DESIGNED BY, SCALE, 1' = 60' COUNTY PROJECT NO, Uw-97-I3-DS WATER ASSESSMENT PROJECT o f 21 MICHAEL C. HOTCHKISS APPROVED BY. VA CONST. 20 L.F-6" CL.350 DIP. W. CENTERED, UNDER EXISTING STORM PIPE w 18" MIN. E VERT. CLEARANCE (TYP-) - S //DETAIL M-6 NJW.- No, Revision "CONST. 62' PVC. W.M. AS SHOWN wl MIN. 36" COVER & RESTORE IN KIND. INSTALL 6"I x 4" M.J. TEE 4" M.J.G.V. i9 INSTALL 6" x 6" M.J. TEE 6" M.J.G.V. # mW710040 W-- 101.20 CL- 101.32 Nr-- 101.00 Nw.- 100.17 S-)Ny'- 93 OPEN CUT ASPHALT RD. & RESTORE IN KIND. CONST. 48' L.F. CL.350 DIP.,, INSTALL 6" x 6" M.J. TEE 6" M.J.G.V. I CIVI el N.W '- 97.95 At 99.97 Ali-- 101.00 00.00 CONST. 20 L.F-6" C LX50 DIP. W.'Ni CENTERED, UNDER EXISTING STORM PIPE w/ 18" MIN. VERT. CLEARANC4TYP.) SEE DETAIL M-6, ov i / / INSTALL 6"' x 6" M.J. TEE - 6" M.J.G.V (2) MATCHLINE SEE SHEET 4 & RESTORE IN KIND. CONST. 32 L.F. CL.35,0. DIP. DEPARTMENT OF TECHNICALs BLANKEN DESIGNED BY, MICHAEL C. HOTCHKISS UTILITY SERVICES APPROVED BY, 0 L-350 DIP. W.M CENTERED, RM PIPE w/ 18" MIN. (P.) - SEE DETAIL M-6 a SCALE,, I' - 60" 6 � ------ sN. V t F;y DATEo SHEET DULY 99 _____�_� �_ _______.___ S E BASTIAN PHASE 2D SCALE, V = 60' COUNTY PROJECT NEI. U\,1-97-13—DS WATER ASSESSMENT PROJECT 21 OF I 1 CD cc -J No, QD MATCHLINE SEE -SHEET 13 , 4.2 DIRECTIONA \, ORE 6" W.M. ``°�� G P ---.—INSIALL M.J. BEND 45' INSTALL 6" x 6" W, ,` 95.12 a` M.J. TEE cx.- ,doss 6 M.J.G.Vm- 100.00 __..__. W- ,00.00 S.W.- 9A02 ' A BORE 6" PVC. W.M. y t!) D._ / UNDER CONC. DR. (TYP) " ( D m • n m / INSTALL F.H.A _ W m / m 'DIRECTIONAL BOR .6" W.M. ONST. 6., PVC. W.M. r DIRECTIONAL BORE AS SHOWN ...._ _ 6 W.M. % w/ MIN. 36-" COVER & RESTORE IN KIND. INSTALL F.H.A ' n CITRUS AVE s• 0) BORE 6" PVC. W.M. A - / el UNDER CONC. DR. TYP I INSTALL 6" x 6" t \ / M.J. TEE 6" M.J.G.V / � I - 0 Z 1 V) OPEN CUT ASPHALT RD. '` & RESTORE IN KIND. _ s. (CONST. 200 L.F CL.50 DIP.) / OPEN CUT ASPHALT RD. & RESTORE IN KIND. CONST., 48 L.F. CL.350 DIP. cn G - C.) CONST. 6" PVC. 1'V.M. 6" W MZ. BORE AS SHOWN N.W, - 9&29 w/ MIN. 36" COVER „w-:99.90 ' ,00.30 / & RESTORE IN KIND. (� F ` .� F Ca .`�� �� _; .2 HN i 100.00 AL BORE �vr�`A TOP of ►�,o�wu.l- ,00.92 DIRECTIONAL T N ""•' '" D R C 10 ._M ��A-__� 12 W.M. INSTALL 6 x 6 �av- 99.4, M.J. TEE' x rti t a - ORANGE AVE r `r^� Y'ti 'Y W.. � 9e.14 CONST. 12" PVC. W.M. 9,v- 99.01 AS w/ MINW36" COVER & RESTORE IN KIND. / W.W. �.s+ / INSTALL 6" x 6" "'"'' 100'00'� ' M.J. TEE I I INSTALL 45' M.J BEND MG.- - 100.50 G .-' %"' INSTALL M.J. BEND MG-- 101.7,1 J ., /� 45' 16" M.J.G.V i �- = INSTALL 45' M.J BEND(2) INSTALL 12" M.J.P.V SEW10029 6" M.J.G.V INSTALL F.H.A ! OPEN CUT ASPHALT RD., j / INSTALL 6" x 6" & RESTORE IN KIND. I INSTALL 45' M.J BEND M.J. TEE CONST. 48 L.F. CL.350 DIP. 6" M.J.G.V ._._..-_ _. __� .__._ _. _._ .__ - a, " . INSTALL 12" M.J. TEE DKA 12" x 6" M.J. REDUCER IREWCTIONAL BORE I I 5' (TYP.) CCNST. 12" PVC. W.M. ( I AS SHOWN / CONST. 6" PVC. W.M. i 5' (TYP.) w/ MIN. 36" COVER n AS SHOWN •- � & ',RESTORE IN KIND. PEN CUT ASPHALT RD. &jRE$ G-RE "IN OKIND. '�' - i OPEN CUT DRIVEWAY / p / VEWAY & RESTORE IN KIND ' Z & RESTORE IN KIND. / ! CONST. 12" PVC. W.M (TYP.) CONST. 48 LrF. CL.350 DIP./ INSTALL F.H.A CONST. 6" PVC. W.M. tT1 ' �:�} sAS SHOWN IN LIEU OF OPEN CUT & RESTORE IN KIND, ,// CONTRACTOR MAY DRILL & ° BORE UNDER DRIVEWAY '" ' w/ MIN. 36' COVERrn RESTORE IN KIND. I m VJ (Ali INSTALL 6" x 6" Z � M.J. TEE SORE 6'A PVC. W.M. �» ., 6 M.J.G.V UN.QER CONC. DR. (TYP) ' 4 ! _ m = BORE PVC. W.M. ILd r i UNDER I CONC. DR. (TYP) I m INSTALL M.J. BENDS Z i 10 bbb. lqq dr SCALE- 1 a = 60' 22.5' - 2 m 0 cri '�'I 1) AND APPROVED ERY! w�•- , "° MATNLINE SEE SHEET 7 TOP SLAB 0&05 i m Revision Dote By No, Revision Date By ER TECHNICAL BLANKEN JULY 99 INDIAN RIVER COUNTY I DEPARTMENT ofSEBASTIANSHEET r_ _._ _._ _ . __ _. _ __ . _ _ _ _� __ _ _ _� �...� DATE, � � J�h____ M._ _w ��__._.��.�.� PHASE 2 D .� -- -M _.� . _._ . _ _.-- r _ _. _ . _ ._ _____ I E p 1• = 6U' 1840 2fith STREET SCALE, O ,- � � v�o BEACH, FIAR�DA s2eo � =DESIGNED BY, MICHAEL C. HDTCHKISS CQIINTY PROJECT NQ UV-97-I3-DS� WATER ASSESSMENT PROJECT ' --�� (407) 567-SNO �UTILITY SERVICES APPROVED BY. � of 21 i L0 ro J ONST. 20 L�F-4 CL.3 0 I�:" .M ENTERED, _BEi'fY A �;<;; STING / 1 MIN. U R EXI STO • I ;� -------_ � <. -- --_ --_ - -- — __ _ - _- --- --- - - AIL M-6 r DIRECTIONAL BORE LEARPANCE ( ' F� 6" W.M. W - BORE 6" PVC. W.M. I I ; " INSTALL 6 x 4" _ I UNDER CONC. DR. (TYP) r.. _._.. 3.. M.J. T E, I � MJG.V IN M.J.E,WD 7; SCALE; 1 " = 601 STALL J M DIRECTIONAL BORE S BORE 4"!, PVC. W.M. 22,5' — 2 . INSTALL 6" x 4>, j > ± r W.M. ! � UNDER CONC. DR. (TYP) M.J.TEE f i M.J.G.V s (� 4" , CONST. 4" � VC. W.M. 4 "---- INSTALL M.J. BEN { ) ? 22.5' — 4 5 TYP. INSTALL F.H.A iw:nw.= se.e� ..__5'Y (TYPO _�.,...... wS MHN.W36'' COVER ��/ .. CL 1ODM & RESTORE IN KIND. raw— orv97.00 io{ _ E.- J` BORE 6' PVC. W.M. i/ II�' 'tr w I ' I CONST. 20 L.F-6" CL.350 UP. W. CENTERED, UNDER CONC. DR. (TYP) W UNDER EXISTING STORM PIP w/ 18" MIN. 1 Ll VERT.'LEARANCE (TYP.) EE DETAIL M-6 INSTALL F.H.A W0 W Z \/ BORE 6 PVC. W.M. Z I UNDER CONC. DR. (TYP) " INSTALL F.H.A / CONST. 6" PVC. W.M CONST. 6" /j I I PVC. W.M. AS SHOWN A& SHOWN I w/ MIN. 35" COVER _ I w/ MIN. 36" COVER > / & RESTORE IN KIND. i & RESTORE IN KIND. i S• / 5 (TYP.) �I0 INSTALL M.J. B&D INSTALL M J. BEND \/ / �2.5' w< - . INSTALL F.H.A 22.5 2 �22O INSTALL M.J. BEND G� DIRECTIONAL BORE 22.5• \\ `6 W.M. BORE 6" PVC. W.M. x <2 UNDER CONC. DR. (TYP) :, `\ \ _ _. ,._.v _. $ \ INSTALL 6., x 6,. A , M.J. TEE JY 0 DIRECTIONAL BORE 6" W.M. ,� / 0 INSTALL 6" x 6 M.J.: TEE / \/ / V 6", M.J.G.V CONST. 20 L.F='NSTALL M.J. BENDS6" CL.350 DIF. W.M CENTERED, 90' 22.5' UNDER EXISTING STORM PIPE w/ 18" MIN. \ ` OPEN CUT: ASPHALT RD. / \ / VERT. CLEARANCE (TYP.) - SEE DETAIL M-6 �' �/ 45' & RESTORE IN KIND. CONST. 32 L.F. CL.350 DAP. C0NST. 6" PVC. W.M.Q. ovl AS SHOWN E-`' / \ f �--- �\ ,� c �w/ MIN. 36" COVER ,�\ - � CONST. 6" PVC. W.M. C)G & RI STORE IN KIND. `� \ \\., AS SHOWN / INSTALL 6 x 6 INSTALL F.H.A l w/ MIN. 36" COVER • M.J. TEE & RESTORE IN KIND. 6" M.J.G.V M \ INSTALL M.J. BEND 22.5' O CONST. 20 L,F-6" CL.354.. UIP. W.M CENTERED, INSTALL 6" x 6" UNDER EXISTING STORM PIPE w/ 18" MIN. M.J. TEE VERT. CLEARANCE (TYP.) — SEE DETAIL_ M-6 Q 6" M.J.G.V INSTALL M.J. BEND / 22.5' a 5 CONST. 4" PVC. W.M. AS SHOWN \ " 1 :� -,- / �✓ w/ MIN. 36" COVER & RESTORE IN KIND. � DIRECTIONAL BORE � • 6 W.M.- INSTALL 2" B.0 BORE 6" PVC. W.M. / O UNDER CONC. DR. (TYP) �\ INSTALL F.H.A / I INSTALL M.J. BEND \/ INSTALL 6 x 6 M.J. TEE 1,- 6" M.J.G.V 6 x 4" M.J. REDUCER A. No, Revision Date B No. Revision Date B �ry.__ _ _._.___.r_ .._..__w___ _..._ DATE_ �.. T..._.,....._w _._._... —w_.m.__._e._. y y uv�R ITDIAN RIVER COUNTY DEPARTMENT OF 'TECHNICALi BLANKEN — DULY 99 SHEET _ _ _ w_ . _ _ ____ SEBASTIAN PHASE 2 D 1840 25th STREET __ .. _ _ _..._ 5 SCAIEs 1 60 a 9 • VERO BEACH, FIAREDA 32960 DESIGNED BY, �%� MICHAEL C. HOTCHKISS - -w WATER ASSESSMENT PROJECT aRt P (407) 567-8000 UTILITY SERVICES ICES APPROVED BYE COUNTY PROJECT NO, yUW-97 13—DS� Iy T �1 OF I w Ld LLJ V) w z _j X 0 MATCHLINE SEE SHEET 11 2 CONST. 6" PVC. W.M. AS" SHOWN • F w/ MIN. 36" COVER CONST. 6 PVC. W.M. BORE 6" PVC. W.M. AS SHOWN & oRESTORE IN KIND. (TYP) UNDER CONC. DR. w/ MIN. 36" COVER & RESTORE IN KIND. EE3: L_ (::D C�, k< :51 __5 I" ZI 0- CONST. 6" PVC. W.M. 5 (TYP.) AS SHOWN w/ MIN. 36" COVER 5& RESTORE IN KIND. TYP. ' () --4E> lu BORE 6" PVC. W.M. 5' (TYP.) UNDER CONC. DR. (TYP) 'OPEN CUT ASPHALT RD. OPEN CUT ASPHALT RD. 07.43': N.M.- RESTORE IN KIND.0 OPEN CUT AS HALT RD. & RESTORE IN KIND. NW.- 100M I INSTALL F.H.A W�. loom NO.- 01.50 CONST. 32 L.F. CL.350 DIP. CL- 100.50 & RESTORE IN KIND. CONST. 32 CL.350 DIP. CL- 102-20 NG..- IM40, W-- 101.m E_ E_ I CONST. 32 L.ff. CL.350 D1 lJ SM. 97.70 Ift- 100.00 oom SJW.- 97.57 A -------------- L A bb, A INSTALL 6" x 6" dl/ M.J. TEE 6" M.v.G.V CONST, 6" PVC. W.M. OPEN CUT ASPHALT RD. AS SHOWN RESTORE IN KIND. INSTALL 6" 6" BORE 6" PVC. W.M. MIN. 36" COVER CONST. 31L.F. CL.350 DIP. w M.J. TEE UNDER CONC. DR. (TYP) & RESTORE IN KIND. INSTALL F.H.A a: 6" M.J.G.V 'n INSTALL 6"x 6" CONST. 20 L.F-6" CL.350 DIP. W.M CENTERED, M.J. CROSS WAV.- 94.57 U-) NG.- 99.70 UNDER EXISTING STORM PIPE w/ 18" MIN. 6" M.J.G.V (2) MG' - 100.00 MG.- 99.20 VERT. CLEARANCE (TYP.) SEE DETAIL M-6E3 I CONST. 20 L.F-6" CL.350 DIP. W.M CENTERED, UNDER EXISTING STORM PIPE w/ 18" MIN. VERT. CLEARANCE (TYP.) SEE DETAIL M-6 CONST. 6" PVC. W.M INSTALL F.H.A CONST. 20 L.F-6" CL.350 DIP. W.M CENTERED, INSTALL 6" x 6" AS SHOWN UNDER EXITING STORM PIPE w/ 18" MIN. BORE 6" PVC. W.M. M.J. TEE wl MIN. 36" COVER VERT. CLEARANCE - RANCE (TYP.) — SEE DETAIL M-6, UNDER CONC. DR. (TYP) & RESTORE IN KIND.� OPEN CUT ASPHALT RD. 6" M.J.G.V z & RESTORE IN KIND. INSTALL 6" x 6" m CONST. 32 L.F. CL.350 DipE=—: 1-1--� L__J FEE— M.J. TEE F=:�' F=R I-< IF A qP m 74 OPEN CUT ASPHALT RD. CL- loom w_- 99.70 & RESTORE IN KIND. • CONST. 32 L.F. CL.350 DIP. U) U) CONST. 6" PVC. W.M AS SHOWN < w/ MIN. 36" COVER r 0 & RESTORE IN KINDi B..S.U.G EE3 L_ k< cn DIRECTIONAL BORE DIRECTIONAL BORE 6" W.M. 12" W.M INSTALL 6" M.J.G�V < DIRECTIONAL BORE INSTALL 12"'x 6" INSTALL 12" x 6" INSTALL M.J. BEND DIRECTIONAL BORE 12" W.M. m M.J. TEE M.J. TEE 45 2) 6" W.M. 6" M.J.G.V 6" M.J.G.V E: F:R I E: 41 1w A_W B�S.U,G A B.S.U.G E.W.- B.S.U.G G A ki, S.W.. wo OPEN; CUT ASPHALT RD. INSTALL 12" x: 6" INSTALL 12" x 6" CONST. 6"; PVC. W.M. So &.RESTORE IN KIND. M.J. CROSS M.J. TEE AS SHOWN, STALL 12" x 6" IN CONST. 48 L.F. CL.350 DIP.( f) CONS 12" PVC. W.M. -.V w/ MIN. 36" COVER A 6" M.J.oL INSTALL M.J. BEND M.J. TEE AS SHOWN & -RESTORE IN KIND. 45' (2) 6" M.J.G.V w/ MIN. 36" COVER INSTALL, F.H.A U) RESTORE IN KIND. OPEN CUT DRPVEWAY RESTORE IN KIND INSTALL 6" M.J.G.V W.M.- "A —6" C'.350 DIP. W.M CENTERED, BORE 6" PVC. W.M. CONST. 12" PVC. W.M (TYP.) COAST. 20 L.F NG_- 100-M W MIN. CL- 100.W UNDER EXISTING STORM PIPE W/ 18"' NQ- lockso & RESTORE IN KIND, UNDER: CONC. DR. (TYP) 0- 0 11 5' (TYP.) IN LIEU OF OPEN CUT sm - 100.00 OPEN VERT. CLEARANCE (TYP.) SEE DETAIL M-6 CONTRACTOR MAY DRILL & BORE UNDER DRIVEWAY NQ_ 1=40e & RE' W. . "As EA NM EH3 L_ (:::D (::D CONS INSTALL 6";x 6" 5' (TYP.) (f) U) M.J. TEE INSTALL F.H.A 6" M.J.G.V LIJ . 1 4. INSTALC � M.J. BEND INSTA t. (2) z CONST. 6" PVC. W.M. 45 CONST. 32 L.F.LF, INSTALL ALI E _J V.M. c C7 <11 < AS SHOWN .4a-- AS SHOWN' 0 wl MIN. 36" COVER 0 NJNV. 9&40 III CONST. 6„ PVC. W.M. COVER _j & RESTORE IN KIND. W-100.02 SG w/ MIN. 36 MG.- 100.10 IM oow a. EE3 E� _F _F & RESTORE IN KIND. U) CL- 17 MATCHLINE SEE SHEET 9 DEPARTMENT OF UTILITY SERVICES ALE,, 1' — 601 A CUT ASPHALT RD. STORE IN KIND. 32 L.F. CL.350 DIP. INSTALL M.J. BEND 45' _L F.H.A MICHAEL C. 'HOTCHKISS., FLA, P,E, No, 39514 TECHNICAL, BLANKEN DATES JULY 99 SHEET _____ __ __ ___ __� _ ______u _.r�; S E BASTIAN PHASE 2D SCALE, V = 60' 10�,,- DESIGNED BY, MICHAEL C. HOTCHKISS �.-..-__ -�-APPROVED BY, COUNTY PROJECT NO. UW-97-13—DS �-� WATER ASSESSMENT PROJECT OF 21 a Jo IONOdd AJASSISSV �JJM Y 133HS OZ S`dN d NVIiSV03S ,kq � 1.� a�.l- ?_f NV fql JI A38 g X g �, l r� �c SSA i , ry „� (n SQ-Cf-L6-Mfl 'ON 133f'08d AiNnoo 'Ag Q3AO8ddH lkliriIsll SSI�IHOlOH 'O �3VH0IW '09 = .i 131d0S AS Q3N0IS3Q , 66 A-W '31v N3ANdIS '-lV31NH031 JO iN3VUdVd3a „ �d1SNt O l I33HS 33S 3NIIH0iVY4 °�° r W „9 x „9 liviSN1 I I (dJll) 2i0 'ONOO a3ClNf y, • 'W'M "Ond „9 3808 ' x {a -__- _2 - - -- _ _ --- -- --- - —.. -n-. - - - __ _ _ _ =-A' _C . 7 3�108 TdN011032�10 n0'r"W „9 331 'r'W z. „9 x „9 ��b1SNi I 1 .( 32108 TVN0110381G ores =nn;� ( 8 (d).L) 'ICI 'ONOO �13C1Nn ! ` ;n W"M ,.g (S30dld Z ) 32J08 '�VN01103810 W-M „9 ocroot - H >'W'M 'Ond 9 3�108 3808 O 1O3b10 tie se r 1 to I ayes =,wrM - i 9—W �Iti130 M3S - ('d,,V.) 30NVdV330 '1213 �! " i ;r (d,,i) ,S I t { NIW „8l / 3did N6O1S 0NUSIX3 a30N(�l � —'C13�131N30 W'M 'dlO 09� �O „9--3'l OZ 1SNOO , ('d.11) ,S ! ('did ,9 (l II � � m k:L_.._ ... 9—W 3IV 30 33S — ('dJ.l) 30Nt/2Jb3�0 "ld3n _ �A) 'HCI •0N00 830Nn / t 'NIW „8l /M 3dld MJO1S ONIISIX3 81CIN(1 * I W'M '0nd „9 3aO8 032131N30 W'M 'd10 0�£'1O „9-3'� OZ '1SNOO l �" ('did) ,9 S ri'a8 ='NU'3 ef'L6 - M113 m 00 III 0000t/soot - -n I , I { 000`l -.-10 I l tAJ oz'00t j oaoot a' I ( I 00'00t -MH Wool -MH r, =7W'�' W"96 W NR3 ( V'H'3 �d1SNl ! M1 f <' !! U 0V00� -' ors6 =,vx3 (S3n18(7 Z sian-0N1) NA „9 i I I s►'oo� -N ooroo; ='ON O (� ( i �oo� ..� f art -'0 f I 90'00l - Mt, " L6'66 -'10 i r Z0'L6 WANIA 00'00t -'9N /1I/�t1I 3'_l 06 3b08 _lVN0110381C] ! sp st'oot -•nw 9L'66 -'NAYS 4 f c. 3aO8 _WN011D3610 ; w 1 I (d)d) �JO ONOO d30Nf1 ka I W M Ond „9 3808 { } --I rn �1 I ; 1 d"H'3 I�d1SNi tf"H"3 �_lViSNI 9I.t m_�, K • , � , (I wr r 1 NI 32�O1S32� � } i d3n00 „9� 'NIW /M 7 ( ( NOT-1/4 „9 NMOHS Sb W M Ond „9 iSNOO I «9 x <,9 ��d1SNl ) (� '(INIA N11 380138 _ W'M „9 83n0O „9� 'NIW /M ; 809 IVN0U31810 NMOHS Sf (d ki) '8G 'ONOO �l3QN(1 _W'M 'DAd „9 '1SN0O I 'W"M ''Ond „9 3808 .W'M „9 I W-M „9 1808 -IdN01103810 I 3608 3bN011O360 (S30�1d Z) W'M "9 32J09 �bNoh1032�iC1 , ,- I (pbye _--ti-•--__._____..--_.. 9 L9 Cd0-Fji ci(3•P,L & ai+Se —---�---.- —___b _ _ _ — Y,_y •t Y - / Y Y Y i^Y , �/ �Y r- 1 f 1rY' Y 7- _ _ ".Y �; _ Y- T — tYY �r l� �'[lY'(� r Y_Y_Y'Y YY-y - Y Y .� , 3aO8 IVN0110361CI n O'r"w „9 31 'r'W I �(Z) n O f W „9 «9 x 9 3tf1SNi F 331 'r'W SS0�10 .r.W I 1 « „9 x „9 3�b'1SN1 „9 x „9 ��ViSN1 n• \ N C Orw „9 331 'r'W ONI11 N1 360iS36 _ „9 x „9 -nViSNi 2�3n0O NMOHS Sb F , i I i KM "Ond „9 '1SNOO 1 ; I I � 6 I r,. ! ® OF I _j 94 Lt I� I I f (du) W M 'Ond9d3b08 , Z l I33HS 33S 3N11H0IVV4 0009-499 (40t) d4121D�.r 0962'6 VGMOU 'HOYZH OHZA ILMUS tngz O�9T �Z1�I1103 2�H11I2� NVI(JNII `'�3r�� a n uoiSina ,c a g Q N g Or uoISinaa 'ON d'H'3 7'ViSNi r�Y A Cl /•IAI Q► D Z M fTl n'1 M m LA MATCHLINE SEE SHEET 13 rim R CONST. 4"' PVC. W.M. 5' (TYP.) (= s AS SHOWN CONST. 6" PVC: W.M. (, w/ MIN. 36" COVER AS SHOWN I & RESTORE IN KIND. w/ MIN. 36" COVER ( *\ _._.. _ -_ ___,_____„____ _ ____rwl Q & RESTORE IN KIND. BORE 6" PVC. W.M. UNDER CONC. DR. (TYP) DIRECTIONAL BORE I :,,.. W.M. e /� /6" DIRECTIONAL BORE r DIRECTIONAL BORE � 4 „ W.M. 6" W.M. _ ;m _ , WWI 91.23 NO.— 99.40 CL.- 100.00 NG- 99,80 & S, _ j c �- { r 1 d an ' - U � �,/ INSTILL 6" INSTALL 'M.J BEND 45' M.J.G.V. INSTALL ;F.H.A INSTALL 6" x 6" INSTALL M.J INSTALL 6" M.J.G.V " CONST. 6 PVC. W.M. ;., M.J. TE'= BEND 45'(2) AS SHOWN _ INSTALL F.H.A INSTALL 6" x 4" 6" M.J.G.V INSTALL M.J BEND 45' wj PAIN. 36" COVER CONST. 20 .L.F-65" CL.350 DIP. W.M CENTERED, M.J. TEE INSTALL 6" x 6" DIRECTIONAL BORE & RESTORE IN KIND. UNDER EXISTING; STORM PIPE w/ 18" MIN. 4" M.J.G.V M.J. TEE 6" W.M. VERT. CLEARANCE (TYP.) — SEE DETAIL M-6 CONST. 20 L.F-6" CL.350 DIP. W.M CENTERED, EXISTING 18- MIM-6 5' (TYP.) E3 I-- �� K VERT.UNDER CLEARANCES(ORP)PIP SEE DETAIL B l— CONST. 6" PVC. W. AS SHOWN ' w/ MIN 36" COVER _ & RESTORE IN KIND. OPEN CUT ASPHALT RD. INSTALL F.H.A ^ & RESTORE IN KIND. CONST. 32 L.F. CL.350 DIP. OPEN CUT ASPHA•_T RD. D R (� CD � �� \/ � & RESTORE IN KIND. CONST. 32 L.F. CL.350 DIP. CD � ,,L\ r� - _ — .UINSTALL — L ��, trrw '12" x 6" M.J. TEE Ld 6M.J.G V + " " 12 x 6 CONST. 12" PVC. VN.M. z CONST. 12" PVC. W.M. I I OPEN CUT DRIVEWAY & RESTORE IN KIND ,INSTALL M.J. TEE .. AS SHOWN w/ MIN. 36" COVER INSTALL 12" x 6" _ 0- INSTALL F.H AS SHOWN BORE 6" PVC: W.M. CONST. 12" PVC. W.M (TYP.) 12,E M.J.G.V. _ & RESTORE IN KIND. M.J. TEE w j MIN, 36" COVER UNDER CONC DR. (TYP) IN LIEU OF. OPEN CUT & RESTORE IN KIND, 6 M.J.G.V. e 6" M.J.G.V & RESTORE IN KIND. CONTRACTOR MAY DRILL & BORE UNDER DRIVEWAY I r CONST. 6„ PVC. W.M. I AS SHOWN _ CONST. 6" PVC. W.M. w/ MIN. 36 COVER ° AS SHOWN - & RESTORE IN KIND. w/ MIN. 36" COVER .S.U.G & RESTORE IN KIND. cn o .. OPEN CUT ASPHALT RD. & RESTORE IN KIND. CONST. 32 L.F. CL.350 DIP. W a-- c�io - - �.,0 � N L J � fn c z a ._ -._ _ t� Z-. . ., Y r _ m INSTALL F.H.A INSTALL' 6" x 6" M.J. TEE BORE 6" M.J.G.V UNDER �� 6 PVC. W.M. CONC. (TYP) CONST. 6" CONST' 20 L.F-6" CL.'50 DIP. W.M CENTERED, UNDE EXISTING STORM PIPE w/ 18 MIN. PVC. W.M. VERT. CLEARANCE (TYP.) — SEE _M-6 ; _ INSTALL 6" x 6" y *DR. A SHOWN-- ;. ,DETAIL M.J. TEE 5' (TYP.) wj MIN. 36" COVER 6" M.J.G.V INSTALL F.H.A- &: RESTORE IN KIND:. \y� WIWW,- 97.z3 Wc.- 997. CONST. 20 L. UNDER EXISTI l CL- ,00,00 NG- 99.70 I _ - VERT. CLEARA F-W.- 9725 t CONST. . 20 L.F-6" CL.350 DIP. W.M CENTERED, UNDER :EXISTING STORM .PIPE w/ 18" MIN. � �_ �,� I VERT. CLEARANCE (TYP.) — SEE DETAIL M-6 ^ CL_ �20 �r 9Q0e e INSTALL F.H.A 000NST. 0 6" PVC. W.M. a; INSTALL F.H.A:BORE AS SHOWN INSTALL' 6" x 6" w/ MIN. 36" COVER M.J. TEE & RESTORE IN KIND, 6" PVC. W.M. UNDER CONC. DR. (TYP) INSTALL 6" x 6" - M.J. TEE - J � 6„ M.J.cv C N E 6" M.J.G.V 4 x t__a...I 104 F ° n. .ga. 1-4, N9N- 97A2 NG- 99A0 p¢I Ct - lo0.00 W.- 20 t r. SCALE- I' = 6 0' OPEN CUT ASPHALT RD. & RESTORE IN KIND. CONST. 32 L.F. CL.350 DIP. `OPEN CUT ASPHALT RD. & RESTORE IN KIND. CONST. 32 L.F. CL.350 DIP. —6" CL.350 DIP. W.M CENTERED, IG STORM PIPE w/ 18" MIN. JCE (TYP.) — SEE DETAIL M-6 DIRECTIONAL BORE / 6" W.M. DIRECTIONAL BORE MATCHLINE SEE SHEET 11 CONST. 20 L.F-6" CL.350 DIP. W.M ,CENTERED, �,' _V`1.WED ,AND APPRDV � BY, 6' W.M. UNDER EXISTING STORM PIPE w/ 18 MIN._-._._____ VERT. CLEARANCE (TYP.) — SEE DETAIL M— 6 , r Llr r Al No, fi- �i , kj -A VAE__ _ r .x Not Revision Date B No. Revision Date B �vFR DATEr Y Y TECHNICALr BLANKEN JULY 99 SHEET INDIAN RIVER COUNTY DEPARTMENT of SEBASTIAN P ASE 2D 1840 25th _ __ _.____.___ �_v__ _ wr_ _.__�_�n_ , SCALE i 60' .� � �C� gWMA 0 � DESIGNED BY, MICHAEL C. HOTCHKISS s •�ORI P• �'��� 587-e000 UTILITY SER 1►10ES APPROVED BY, COUNTY PROJECT NO, UW-97_13-DS I WATER ASSESSMENT PROJECT of 21 l I DIRECTIONAL BORE Qyy ' S' �fATCHLINE SEE SHEET fi 6 W.M.' INSTALL 6" x 6" ( .) M.J. TEE , INSTALL F.H.A 6" M.J.G.V O t= V ' SCALE; 1 ' 6 0' t Coll INSTALL M.J. BEND / J / 22.5' - 2_ / NWT=' 995 t�l f �_ BORE 6 ' PVC. W.M. ►+o-_ 00 ( UNDER CONC. DR. (TYP) ;}EJW.M _o 4 r fTl ' \ i c TOP- .0 CONST. 6" PVC. W.M. j tow. 99 ee , . / _ N0.= 101 oo \ V AS SHOWN z �- 1Vi w/ MIN. 36" COVER /r.:r♦ '' & RESTORE IN KIND. i DIRECTIONAL BORE "r'- o - 1_ � ..._ _ _.w___.__.___R... 0) NCB 99 eii 6 W.M ji INSTALL 6 x 6 M.J. TEE J 5' (TYP.) I I CONST. 20 L.F-6" CL.350 DIP. W.M CENTERE I I OPEN CUT SPHALT RD. 6" M.J.G.V UNDER EXISTING STORM PIPE w/ 18 MIN. & RESTORE IN KIND. VERT. CLEARANCE (TYP.), - SEE DETAIL M-6 CONST. 32 L.F. CL.350 DIP. t DIRECTIONAL BORE 60 L.F. 6" W.M (INCLUDE DRIVE) (+ CONST. 6" PVC. W.M / DIRECTIONAL BORE 6 W.M. AS SHOWN INSTALL F.H.A " r av & RESTORE !, N COVER KIND R �1 ,j4_�_ _ NY.-9&75 -- r' i Nf DIRECTI AL 130RE ` INSTALL 6" x 6" _. y !, W `7 M.J. TEE' - -`` - - ----- NG�999 _._ 6 _ _ _ _ _ . _ _ . ._ _ (�100.73 _} / / F 6" M.J.G.V Y Nw,00s - F I W. _ f <B.S.U.G sw Mr.-9e.+o t.... � MlV .47 Nw.N.W100.00 26.05 Li NA Li BORE ! PVC. W.M. DIRECTIONAL BORE W- 100.00 UNDER . CONC. DR. �.. " x 6" 6 W.M. SmV iOaoQ°i°z /TALL 6 x 6 INSTALL M.J.�v1BEND -: i � � � INSTALL 6 - 90 .= 22.5' 2 ; i' M.J. TEE M.J. TEE i 17 i 6" M.J.G.V 6 M.J.G.V c : o O e oc r f INSTALL F.H.A PVC. W.M. I a BORE 6" , GF UNDER CONC. DR. (TYP) I I I CONST. 6" PVC. W.M. I I >. AS SHOWN " ! V • �� ,., ; g: _. � w/ MIN. 36.COVER f. RESTORE IN KIND.x 0 CONST. 6" PVC. W.M. I AS SHOWN I a - / " R ` - w/ MIN., 36COVEj i ' > & RESTORE IN KIND. a E INSTALL 6" x 6" ` _ ;:� , Na= 99 Y0 M.J. TEE — i� C .0. Q a = WN6.= 99OM 40 .40 . E_ � U E 6" M.J.G.V N.W- 95.8f -i , W. �oaoo 'T - N No.= 90.ao �, y INSTALL F.H.A 1 CL= 100.18 Yso M- 99.40 7 x y7fe 5-w &radii DIRECTIONAL BORE If� 6" W.M.JIM_ _ INSTALL 6" x 4" E M.J. TEE z. / 4„ M.J.G.V y BORE 4" PVC. W.M. � INSTALL M.J. BEND 4 `, INSEND UNDER CONC. DR. (TYP) A 22.5' - 2 i -- _____ _ T45' -2 CONST. 4" PVC. W.M.;C7 M.J.M AS SHOWN w/ MIN. 36 COVER T F 4" I I T r INSTALL 6" M.J.G.V - - DIRECTIONAL' BORE - .M CEN ERED ,i „ & RESTORE IN KIND. CONST. 20 L. C� 350 DIP. W Z (� UNDER EXISTING STORM PIPE w/ 18"' MIN. v' jn 4 W.M. VERT. CLEARANCE (TYP.) - SEE DETAIL M-6 m II�STA L F. H.Ar�' U 1 �' BORE 6" PVC. W.M. UNDER CONC. N R. TYP D (TYP) I I m - BORE 6 PVC. W.M. / UNDER CONC. DR. (TYP)- DIRECTI'ONAL BORE S y f! m 6" W.M. m MATCH / I I I ( rnn T R" PVC W AA CONST. 6" PVa W.M. onoc c$ 01if- u, ., r t No,V Revision cu E En ro J ' I AS SHOWN , }: / DIRECTIONAL BORE I ! BARE 6" PVC. W.M. w/ MIN. ' 36 COVER UNDER CONC. DR. (TYP) ' " r - " r 6 W.M. & RESTORE IN OKIND. UNDER CONC. DR. TYP RESTORE CONST. 20 L F- CL.350 DIP. WM CENTERED, / ( & E R N RED, j 4 NSTALL M.J BEND UNDER EXISTING STORM PIPE w/ 318" MIN. ;VERT. CLEARANCE (TYP.) - SEE DETAIL M-6 00 IN $T L L FHA W F I V U { 'f INSTALL 6" x 6" _ �' P.) v j 1 M.J. TEE to : cN. . 6 M.J.G.V w y W �. N.w= 96so zy N6= �.40 NG= ".10 s�— 96. eo 15' (TYP.)CONST. 6PVC. W.M. I � is f J AS SHOWN — w/ MIN. 36" COVER 5' ( P.) ' s t ' 16 15 1420 t3 } t i E-- & RESTORE IN KIND. m i W y RE IE'WED AND APPROVED BY= r .:. irk " { 4� CHAEL Cf HOTCHKISS, � � P.E. No. 39514 I MATCHLINE SEE SHEET 12 a� DATES ' Date By No, Revision Date By �`�'ERc INDIAN RIVER COUNTS s DEPARTMENT OF i�TECHNICAL� ___ BIANKEN� .�JLY 99 SHEET -�----�-�- ; _ - ----- SEBASTIAN PHASE 2 D _ .... - __ ° 13 1840 2Sth STREET ._...... ... � _ _ . _..... -....: _ ... .. ._ _.. _.. ..., 4 DESIGNED BY, � SCALE, 1 60 ...y • ���� . 0 r}' 80 0 0 UTILITY SERVICES MICHAEC C. �TC ISS _ __-._ P_- E _ _ _ _ ___ - - WATER ASSESSMENT PROJECT � z 1 x' P `APPROVED BY, COUNTY PROJECT NO.'U�J-97-13—DS OF s � � CD E cn ro J L 'BORE IN5IALL F.H.A / DIRW MO(INC1tiUDES 2DDRlVES)' / OPEN CUT CONS. SIDEWAL EXISTING » 12" VALVE OPEN CUT CONC. SIDEWALK INSTALL M.J. BEND & RESTORE IN KIND. \ 11.25• (2) CONST�. 6" PVC. W.M. INSTALL F.H.A & RESTORE IN 'KIND. \\ \ CONST. 12" PVC. W.M. AS SF�OWN EXISTING 6" PVC. F.M. \ w/ MN. 36" COVER AS \ \ w/ MINW36" COVER \�!y & RESTORE IN KIND. \\ & RESTORE IN KIND. E3 INSTALL 12" x 12" M.J. TEE, AFTER CLOSING BOTH VALVES. I I EXISTING PIPE BETWEEN VALVES SHALL BE CHLORINATED AND TESTED. \ \ LINE SHALL REMAIN OUT OF SERVICE, \ \\ \ -7 FR G --F UNTIL LINE HAS BEEN CLEARED BY F.D.E.P. \ THIS PORTION OF WORK SHALL BE DELAYED UNTIL \ REMAINING WATER MAIN HAS BEEN CONSTRUCTED AND TESTED. INSTALL TEMPORARY JUMPER \�_ EXISTING 12" PVC. W.M. TEMPORARY SAMPLE POINT No. Revision Date By Nal Revision Date INDIAN RIVER COUNTY 1840 25th STREET VERO BEACIL FLOREDA 92960 �'`Z( IMP• (407) 567-8000 DATE'_,.._.�_.._.__�_._._.._._.._.JU.Y 99 — SCALE, 1' = 60' COUNTY PROJECT NO. UW-97 13—DS W U) W W W W z J C.) H Q o N , __�-�--_ -v.I [ s-a_ n - _' _— _t .-. _. _ � � e o � Da e 1 B MATCHLINE SEE SHEET 11 MATCHLINE SEE SHEET 12 PT INDIAN RIVER COUNTY 1840 25th STREET ROV$BEACH,FL�OREDA 32960 r (407) 567-8000 DEPARTMENT OF UTILITY SERVICES CONST. 12" PVC. W.M. AS SHOWN w/ MIN. 36" COVER & RESTORE IN KIND, MATCHLINE SEE SHEET 12 AND APPROVED Dya a l� SCALE' 1 " = 60" CONST. 12" PVC. W.M. AS SHOWN w/ MIN. 36" COVER & RESTORE IN KIND. DRIVEWAY & RESTORE IN KIND " PVC. W.M (TYP.) OPEN CUT & RESTORE IN KIND, R MAY DRILL & BORE UNDER DRIVEWAY DIRECTIONAL BORE 90 L.F. 6" W.M (INCLUDES 2 DRIVES) C. NCB KIT, SS; F 1-A. P,E No, 39514 ._s.....e....w..+.re....s.....wv.r�....o�.. _ _ _�..�..w.a.....®. ,.:. .. ............e»..........w...s....+w....rwv...........r.......nm�..ti�.r ... �............a,.�a. r.e�.....-re...�Na�...m...�a.:.....�e..... DATEt4 �..��.. _. TECHNICAL+ BLANKEN JULY 99 ! SHEET DESIGNED BY � SEBASTIAN PHASE 2 D � SCALE, V = 60' I 15 fi -1- MICHAEI_ C. HOTCHKISS __...._._ ...... _ APPROVED BYE i C[X1NTY PROJECT NO, UW-97 13 N�DS WATER ASSESSIVIENI PROJECT I of 21 i F 1 i CONST. 4" PVC. W.M. AS SHOWN w/ MIN. 36" COVER & RESTORE IN KIND. e 5' (TYP.) 5° (TYP.) 1 i MATCHLINE SEE SHEET 13 5' (TYP.) m I ; CONST. 6" PVC. W.M. CD AS SHOWN w/ MIN. 36" COVER & RESTORE IN KIND. r� DIRECTIONAL BORE DIRECTIONAL_ BORE _, - _, 6 W.M. DIRECTIONAL BORE 6 W.M. 4" W.M. B.S.U.G_ _ ` --- B.S.U. _ B,S.U.G _ INSTALL 12" x 12" DIRECTIONAL BORE M.J. CROSS � /� � r INSTALL 12 x 6" 12" W.M. 12" x 6" M.J. REDUCER (2) # M.J. TEE 6" M.J.G.V (2) ` INSTALL F.H.A 12" M.J.B.V - 6" M.J.G.V CONS`. 12" PVC. W.M. INSTALL 12" x 4" AS SHOWN M.J. TEE 4' OPEN CUT DRIVEWAY & RESTORE IN KIND w/ MIN. 36" COVER 4" M.J.G.V CONST. 12" PVC. W.M (TYP.) & RESTORE IN KIND. IN LIEU OF OPEN CUT & RESTORE IN KIND, CONTRACTOR MAY DRILL At BORE UNDER DRIVEWAY I B l— BORE 6" PVC. W.M. I CONST. 6" PVC. W.M., UN ER CONC. DR. (TYP) AS SHOWN w/ ^MIN;, 36 ,COVE\ /� „ 1 /�L \ R(lAr' All pwr W AA lkicTni i C' u n W (n w V) w z U Q yr C 0 ter DIRECTIONAL BORE 6" W.M. 70L AM _ ._ dh B.S.U. I BORE 6" PVC. W.M. INSTALL 6" x 6" UNDER CONC. DR. (TYP) M.J. TEE INSTALL F.H.A 6" ' M.J.G.V hCONST. 6" PVC. W.M. AS SHOWN w/ MIN. 36" COVER & RESTORE IN KIND. F=:;�,' (=7 OPEN CUT GRAVEL RD. & RESTORE IN KIND. CONST. 16 L:F. CL.350 DIP. 0 �I {I Z INSTALL F.H.A 3 S-i-. U eGr-- C") 2 r z m m m mm J —F F::� C CONST. 12" PVC. W.M. AS SHOWN w/ MIN. 36" COVER & RESTORE IN KIND. CONST. 6" PVC. W.M. AS SHOWN w/ MIN. 36" COVER & RESTORE IN KIND. CONST. 6" PVC. W.M. AS SHOWN w/ MIN. 36" COVER & RESTORE IN KIND. Alk- SCALE. 1 ' _ 601 r F—a NO, Revision Date By No, Revision Date By O"OR TECHNICAU BLANKEN DATE JUCY 99 n SHEET INDIAN RIVER C0UNTY DEPARTMENT OF __ SEBASTIANPHASEL ___..__ . _._.-----.._ .....___ n._...., SCALE, 1 _60 _._ 16 _ 184U 25th .g ' � -�J� DESIGNED BYE VERO BUCIL 07 56°eo0 980 UTILITY SER V 10ES MICHAEL C. HOTCHKISSCOUNTY PROJECT NO. UW-97_13-DS WATER ASSESSMENT P R 0 J E CT F 1 j APPROVED BY, EXISTING F.M VALVE,, No,TRevision DIRECTIONAL BORE / 6" W.M. Date�T-Bv✓� No, DIRECTIONAL BORE 12" W.M. / DIRECTIONAL BORE f 6" W.M. s F� f N.W. e`+�. 9e.99 01 Nw.- 1oG.oe �V Gj / NG.- 101.00 CL.- 102.50 y NG.- 01.50 W. �. 9e ee S 9N. 6 - NOT P UMND , DIRECTIONAL BORE 6" W.M. . xA N.W1 - 95.55 MG:- ; oo i NSTALL 6" x 6" rc- 10070 � t M.J. TEE a 95.15 J. 6" M.J.G.V INSTALL M.J. BEND f ' 22.5' - 2 CONST. 6" PVC. W.M.--- AS SHOWN / w/ MIN. 36" COVER tle RESTORE IN KIND.• W IINSTALL M.J. BEND � 22.5' - 2 M.J 'BEND ' INSTALL F.H.A"",4-,", U CONST. 6" PVC. W.M. AS SHOWN _. w/ MIN. 36" COVER & RESTORE IN KIND. NST. 20- L.E-6" CL.350 DIP. W.M CENTERED, W DER EXISTING STORM PIPE w/ 18" MIN. LL! R T. CLEARANCE (TYP.) - SEE DETAIL M-6 INSTALL M.J. BEND rj 22.5. INSTALL 12" x 6" M.J. TEE 6" M.J.G.V IN TALL M.J. BEND INSTALL M.J. BEND 45' (2) 22.5' V, INSTALL M.J. BEND 22.5* N.W.- 97.61, W.- 100.00 NG- 99.e5 a.- 1oo.zo NG.- 99 9O 100.00 S.W.- 97.61 ---.1_DIRECTIONAL BORE CONST. 12" PVC. W.M. 12" W.M. AS SHOWN w/ MIN. 36" COVER & RESTORE IN KIND. �\ DIRECTIONAL E30RE 12" W.M. DIRECTIONAL BORE 6" V.M. INSTALL 12" x 6'y INSTALL 6"'x 6" B L— CD C I M.J. TEE M.J. TEE INSTALL F.H.A 6" M.J.G.V 6" M.J.G.V' INSTALL M.J. BEND 22.5' oq B_S`USz_ 1wKiGOLUMBUS �d --, BORE 6" PVC. W.M UNDER CONC. DR (TYP) NON.- 98.73 KW.- 9 _ r . 4 NG..- 10000M ME- 100.10 � � - w- Imm - - 1 G : i�'S�0 CL- 100.74 4 NG.- 100.50 tIN.- 100.00 i . 9 .26 5' (TYP.) &W.- 97.00 \ � 1, DIRECTIONAL BORE INSTALL M.J. BEND ECTIONAL BORE 12" W.M. ' ! I DIRI `' 22.5' MATCHLINE SEE SHEET 13 MATCHLINE SEE SHEET 16 SCALE; 1 ` = 60' `E-f SoiF-D AND APPF'O ED B'yt HE FLA, RE 39514 No. DIAN RIVER COUNTY DEPARTMENT OF}TECHNICAU HLANICEN ; _ �JULY 99 TiH7EE SEBASTIAN . PHASE 2 D17 _ . �__ ._ .. -_ _. _ . -_ ._- _._ _._..- _.. _ n.__... _ �_ �. _ _ _ _ __ ....__ _ DESIGNED BY, ' 184�0 25th ��'J)�T _ �...�.�_.�__.._._. _ _ } � SCALES 1' - 60' VM BLACH. FWRMA 32I6O I MICHAEL C. HOTCHKISS -- -.- �- (4W) W7-WOO UTILITY SERVICES APPROVED BY, { ~ COUNTY PROJECT ' NO, UV-97-13-DS WATER ASSESSMENT PROJECT I z 1 OF 0 7- c) O I - z I CITY HALL (y TRACT B �77 REPLAT OF SCHOOL PARK SUBD. m PB # 2 PG 29 i CITY OF SEBASTIAN COMPLEX INSTALL 2" SINGLE SERVICE, INSTALL\ 2" SINGLE SERVICE IBLOCK 2 SEBAS T IAN POLICE REPLAT PP F � SCHOOL SUBp PG 29 DEPARTMENT INSTALL M.J. BENDS TO AVOID LARGE TREES. I CUNSI. 12 NVU. W.M. — I AS SHOWN OPEN CUT DRIVEWAY & RESTORE IN KIND OPEN CUT ASPHALT RD, w/ MIN. 36" COVER CONST. 12" PVC. W.M (TYP.) & RESTORE IN KIND. & RESTORE IN KIND, IN LIEU OF OPEN CUT & RESTORE IN KIND, CONST. 32 L.F. CL.350 DIP. CONTRACTOR MAY DRILL & BORE UNDER DRIVE4�lAY 7 _ �� ---� EXISTING F.M VALVE INSTALL 2" w/ MIN. 36" COVER & RESTORE IN KIND. No, I Revision I Date TG NoJ Revision 1 Date B INDIAN RIVER COUNTY 1840 25th STREET + + VERO BEACH, FLORIDA 32960 �tI P (407) 587-8000 \ ♦Tl �� L� ij\, DRE U,52 /� _ CATCH BAS _6IM.18.85 E BOTTOM I$.B5 w I. D,. 3 20.46 INSTALL 12"x12"x 8" M.J. TEE BOTTOM 23 12" M.J. PLUG 3 INSTALL 1>2" M.J. BEND INSTALL F.H.A SCALE, I" = 60' EXISTING 8" W.M 10 REMOVE PLUG & CONNECT �i INSTALL TEMPORARY JUMPER INSTALL TEMPORARY S.P A. ROSE SUBDIVISION d s 4 RE�TOREI IN KIND. 12",PV9. ,W.M. ( MI 42" COVER) t SAS SHOWN I I w/ MIN. 36 COVER & RESTORE IN KIND. FLOCK 3 I REPLAT OF SCHOOL PARK SUBO. 11, POST OFFICE # OPEN CUT COfjC. DR./ & RESTORE IN KIND. OPEN CUt H.S DR. I ( MIN. 42 COVER),, & RSTORE IftfND. "- OPEN CUT H.S 'DR ( MIN. 40 COVER) <;c RESTORE IN KIND, ( MIN. 42" COVER) A.G. ROSE 8 UBDIVISION DEPARTMENT OF I TECHNICAL- BLANKEN IDESIGNED BY, MICNAEt_ C. HOTCHKISS UTILITY SERVICES APPROVED BY; 0 'Pool o /0o 2g 0 & KtJ 1 VKt IN KIINU. 0o 0 m MT T DATEi DULY s9 SCALEt 1' 60' � iSHEET _ _ t SEBA'71AN PHASF 2 D 9 - = I 18 COUNTY - PROJECT NO, UW-97-13-DS WATER ASSESSMENT PROJECT 21 i CRUSHED STONE SURROUNDING BALES STORM SEWER INLET TOP OF BERM TO BE CONTINUED TO MATCH PUMP HOSE EXISTING GRADE OR PIPE A ,. ,*A FLOW 5 ;' EMBEDDING DETAIL CURB, EDGE OF ROADWAY, OR STRUCTURE __// PUMP HOSE OR PIPE BALES OF HAY OR STRAW �k SPECIFIC DESIGN DETAILS AND DIMENSIONS TO BE PROVIDED BY THE CONTRACTOR. `— BALES OF HAY GRAVEL INLET FILTER OR STRAW (SEE EXIST. CATCH PLAN BASIN FILTER DETAIL) kTER DISCHARGE PIPE HAY OR STRAW BALES 0ow "pow L EXISTING GRADE VARIES STORM SEWER INLET SECTION A -A DEWATERING STRUCTURE N.T.S. �50 GAL. DRUM INSTALL BAFFLE- 1/4" PLATE WITH 1-1/2"0 HOLES 3" O.C. EA. WAY — I PERFORATE SIDES OF DRUM ABOVE BAFFLE W/3/4"0 HOLES 8" O.C. EA. WAY WELD 4 CLIPS TO DRUM TO SUPPORT BAFFLE NOTE: FOR USE WHEN PUMPING RATE IS 20 GPM OR LESS SEDIMENT TRAP DETAIL N.T.S. FENCING FOR TREE PROTECTION N.T.S. 2"x2"x4' WOODEN STAKES (2 FOR EA. BALE) FU HAY OR STRAW BALE SILT FILTER N.T.S. EL A SILT FENCE LIKE THIS TRAPS THE SEDIMENT IN RUNOFF WATER ON SFTE WHILE PASSING RELATIVELY CLEAR WATER. TYPICALLY IT IS MADE UP OF LIVESTOCK WIRE FENCE FASTENED ONTO WOODEN FENCE POSTS. A FILTER FABRIC, SUCH AS CELANSE'S MIRAFI 140 OR CARTHAGE MILL'S POLLYFILTER-X, IS FASTENED TO THE FENCE. THE BOTTOM END OF THE FABRIC LAID IN IT AND THE TRENCH BACKALLED THE SILT FENCE IS A TEMPORARY SILT CONTROL MEASURE. IT IS REMOVED ONCE VEGETABLE COVER IS ESTABLISHED. EVENTUALLY, THE SUN'S RAYS WILL DEGRADE THE PLASTIC FILTER FABRIC. WOODEN POST WIRE FENCE MIRAFI 140 FABRIC OR EQUALIVALENT —�— TYPICAL SILT FENCE DETAIL N.T.S. AE TOE OF SLOPE NOTE: FOR USE ON WATERSHEDS LESS THAN 2 ACRES PLAN TOE OF SLOPE 0 EXISTING I 2'-0" GRADE RUBBLE OR WELL GRADED GRAVEL SECTION A -A FILTER BERM DETAIL N.T.S. EDGE OF EXIST. PAVEMENT 100' MIN. rn rrn r -- WOODEN POST MIRAFI 140 FABRIC OR EQUALIVALENT /_ GRADE EXISTING PAVED CRUSHED STONE ROADWAY SECTION A -A 100' MIN z z ui A : I A w a a z CRUSHED STONE X w w 0 w w PLAN CONSTRUCTION SITE TRACKING PAD NOTE N.T.S. EXISTING GRADE OF GRAVEL SURFACE VARIES. LEVEL SUBGRADE BENEATH FABRIC FILTER AND CRUSHED STONE WEARING COURSE TO MEET EXISTING PAVED ROADWAY ON EITHER SIDE OF TRACKING PAD. HAY BALES (TYP.) — A L ANCHOR PINS (TYP.) 12= TO BE EMBEDDED WHENEVER POSSIBLE A. B. PLAN 10'-0" MIN. WELL GRADED GRAVEL OR RUBBLE EXISTING STORM SEWER INLET 2" EXISTING GRADE SECTION A -A EXISTING CATCH BASIN FILTER DETAIL N.T.S. PREPARE ANCHORING TRENCHES AT THE TOP AND BOTTOM OF SLOPES. BURY THE TOP ENDS OF THE MATTING STRIPS IN A TRENCH 4 INCHES OR MORE IN DEPTH. ' GRADE J HAY BALES (TYP.) L PLAN SECTION "A -A" SEDIMENT CONTROL DETAIL FOR NOTE: FOR STOCKPILING ERODIBLE MATERIAL FOR EXTENDED PERIODS THE AREA SHALL BE SEEDED AND MULCHED A STOCKPILING OF ERODIBLE MATERIAL N.T.S. C. ALLOW 4 MIN. OVERLAP--\ OVER P P D. PLACE STAPLES 4' TO 10' APART TAMP THE TRENCH FULL OF SOIL. SECURE WITH ROW OF EROSION STOP -FOLD OF MATTING STAPLES. 10 INCH SPACING 4 BURIED IN SILT TRENCH AND INCHES DOWN FROM TRENCH. TAMPED. DOUBLE ROW OF STAPLES. EROSION STOPS SHOULD BE INSTALLED AT THE MIDPOINT OF SLOPES GREATER THAN 50 FEET IN LENGTH; OR AT 50 FOOT GRADE INTERVALS MEASURED FROM TOP OF SLOPES GREATER THAN 100 FEET IN LENGTH. EROSION PROTECTION WITH SOIL STABILIZATION MATTING N.T.S. NOTES: APPLICABLE FOR JUTE MESH, BIODEGRADABLE MESH NETTING, AND 0 EXCELSIOR MATTING (EXCEPT EXCELSIOR MATTING MAY BE BUTTED). LIME FERTILIZE AND SEED IN ACCORDANCE WITH THE SEEDING F —1" SPECIFICATION TBE APPLIED EXCEPT THAT R JUTE MESH. ONE HALF OF E PRIOR TOLAYING THE MATTING AND THE SEEDMAY REMAINING SEED APPLIED AFTER LAYING THE MATTING. TYPICAL STAPLES (8 GA. WIRE) N.T.S. LA -BURY U PER END OF LOWER STRIP AS IN "A" AND "B" OVERLAP END OF TOP STRIP 4 INCHES AND STAPLE AT 10 INCH INTERVALS. SOIL EROSION AND SEDIMENT CONTROL NOTES: 1. ALL SOIL EROSION AND SEDIMENT CONTROL PRACTICES TO BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCE, OR IN THEIR PROPER SEQUENCE, AND MAINTAINED 8. THE ENGINEER SHALL BE NOTIFIED 72 HOURS IN ADVANCE OF ANY LAND DISTURBING ACTIVITY. 17. ALL SOIL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE IN PLACE WHERE SEQUENCE OF CONSTRUCTION: UNTIL PERMANENT PROTECTION IS ESTABLISHED. POSSIBLE PRIOR TO, OR IMMEDIATELY FOLLOWING SITE AND ACCESS CLEARING. 2. ANY DISTURBED AREAS THAT WILL NOT RECEIVE PERMANENT RESTORATION WITHIN 9. AT THE TIME WHEN THE SITE PREPARATION FOR PERMANENT VEGETATIVE STABILIZATION IS GOING TO BE ACCOMPLISHED, ANY SOIL THAT WILL NOT PROVIDE 18. ALL SOIL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE LEFT IN PLACE 1. CONSTRUCT TEMPORARY STONE TRACKING PAD AS INDICATED ON PLANS. TEN (10) DAYS AFTER FINAL GRADING, AND NOT SUBJECT TO CONSTRUCTION A SUITABLE ENVIRONMENT TO SUPPORT ADEQUATE VEGATIVE GROUND COVER, SHALL AND MAINTAINED; INCLUDING SILT AND SEDIMENT REMOVAL, UNTIL CONSTRUCTION IS COMPLETED, AREA STABILIZED AND THE ENGINEER SO DIRECTS. 2. CONSTRUCT SILT FENCE WITH STONE BASE SEDIMENT BARRIER AS INDICATED ON PLANS. TRAFFIC, WILL IMMEDIATELY RECEIVE A TEMPORARY COVER. THE DISTURBED AREAS WILL BE MULCHED WITH STRAW, OR EQUIVALENT MATERIAL, AT A RATE OF TWO (2) BE REMOVED OR TREATED IN SUCH A WAY THAT WILL PERMANENTLY ADJUST THE SOIL CONDITIONS AND RENDER IT SUITABLE FOR VEGETATIVE COVER. IF THE REMOVAL OR 3. SECURE CATCH BASIN INLETS WITH SEDIMENT CONTROL BARRIERS AS INDICATED ON PLANS TONS PER ACRE, ACCORDING TO STATE STANDARDS. TREATMENT OF THE SOIL WILL NOT PROVIDE SUITABLE CONDITIONS, NON -VEGETATIVE 19. ALL DEWATERING OPERATIONS MUST DISCHARGE DIRECTLY INTO A SEDIMENT FILTER AREA. SEDIMENT FILTER SHALL BE INSTALLED IN ACCORDANCE WITH THE 4. INSTALL SEDIMENT CONTROL BARRIER IN AREAS DEDICATED FOR STOCKPILES OF 3. PERMANENT VEGETATION TO BE SEEDED OR SODDED ON ALL EXPOSED AREAS WITHIN MEANS OF PERMANENT GROUND STABILIZATION WILL HAVE TO BE EMPLOYED. A SUITABLE ENVIRONMENT TO SUPPORT ADEQUATE VEGETATIVE GROUND COVER, SHALL CONTRACT DOCUMENTS AND THE DETAILS OF DESIGN AND CONSTRUCTION SHALL BE PREPARED AND SUBMITTED BY THE CONTRACTOR TO THE ENGINEER AND THE COUNTY STONE AND EXCAVATED MATERIAL AS INDICATED ON PLANS. TEN (10) DAYS AFTER FINAL GRADING. MULCH TO BE USED AS NECESSARY FOR PROTECTION UNTIL SEEDING IS ESTABLISHED. FOR REVIEW. 5. REMOVE AND STOCKPILE EXISTING SURFACE STONE AS PRACTICAL. 10. THE CONTRACTOR SHALL TAKE NECESSARY MEASURES TO MAINTAIN DUST CONTROL. 4. ALL WORK TO BE DONE IN ACCORDANCE WITH THE STANDARDS FOR SOIL EROSION AND DIRT HAUL ROADS SHALL BE SPRINKLED WITH WATER OR GIVEN A SURFACE OF CRUSHED STONES OR WOODCHIPS AS REQUIRED. VEHICLES SHALL BE CLEANED, AS 20. SOIL STABILIZATION METHODS SHALL BE UNDERTAKEN COINCIDENTALLY WITH ALL MAJOR SITE IMPROVEMENTS AND CONTINUE DURING THE ENTIRE CONSTRUCTION 6. CONSTRUCT GROUND WATER DEWATERING FILTER AS REQUIRED AND AS INDICATED ON PLANS. (DETAILS TO BE SUPPLIED BY THE CONTRACTOR). SEDIMENT CONTROL. NECESSARY, PRIOR TO USING PUBLIC STREETS. PAVED ROADS SHALL BE SPRINKLED ACTIVITY PERIOD. 5. IMMEDIATELY FOLLOWING INITIAL DISTURBANCE OR ROUGH GRADING, ALL CRITICAL WITH WATER. 7. PROCEED WITH CONSTRUCTION ACTIVITIES (EXCAVATION, ETC.). AREAS SUBJECT TO EROSION (I.E.; STEEP SLOPES AND ROADWAY EMBANKMENTS) WILL RECEIVE A TEMPORARY COVER OF STRAW MULCH OR A SUITABLE EQUIVALENT, 11. ALL SOIL EROSION AND SEDIMENT CONTROL DEVICES SHALL BE LOCATED IN THE 21, DURING CONSTRUCTION, THE CONTRACTOR SHALL NOT DISTURB AREAS BEYOND THE PROPERTY LINE ADJACENT TO THE CONSTRUCTION AREA. 8, COMPLETE UNDERGROUND CONSTRUCTION ACTIVITIES; BACKFILL AND COMPACT SOILS, AT A RATE OF TWO (2) TONS PER ACRE. FIELD AS REQUIRED OR AT THE DIRECTION OF THE ENGINEER OR COUNTY PERSONNEL. BRINGING TRENCHES TO REQUIRED GRADE ELEVATION. THE CONTRACT DRAWINGS ARE NOT INTENDED TO SHOW THE LOCATION AND DETAILS FOR 6. ANY STEEP SLOPES RECEIVING PIPELINE INSTALLATION WILL BE BACKFI AND ALL SUCH DEVICES BUT ARE TO BE USED AS A REASONABLE GUIDE. 22. THE CONTRACTOR SHALL TAKE ADEQUATE PRECAUTIONS TO INSURE THAT ANY MUD, 9• RESURFACE AREA IMMEDIATELY UPON BACKFILLING WITH EXISTING STONE STORED STABILIZED DAILY, AS THE INSTALLATION PROCEEDS (I.E.; SLOPES GREATTERER THAN 12. UPON COMPLETION OF CONSTRUCTION WORK AND AFTER FINAL GRADING AND WHEN SILT, BROKEN CONCRETE, ETC. DOES NOT ENTER EXISTING ACTIVE WATER COMPONENTS DURING THE CONSTRUCTION. ON -SITE, NEW STONE OR TEMPORARY BITUMINOUS PAVEMENT AS APPLICABLE. 3:1) PERMANENT STABILIZATION HAS BEEN ESTABLISHED, THE BALES, SILT FENCES AND ALL OTHER SOIL PLAN APPURTENANCES WILL BE REMOVED AND DISPOSED OF BY THE CONTRACTOR. 10. RESURFACE VEGETATION AREAS IMMEDIATELY UPON COMPLETION OF CONSTRUCTION 7. NEW GRAVEL PAD SHALL BE INSTALLED WITH 1-1/2" TO 2-1/2" STONE, AS 13. ALL EXCESS EXCAVATED MATERIAL, EXCEPT FOR TOP SOIL, WILL BE REMOVED FROM ACTIVITY IN EFFECTIVE AREA WITH SOD OR APPROPRIATE VEGETATION, PER TRAFFIC CONTROL STANDARD REQUIREMENTS, IMMEDIATELY AFTER INITIAL THE SITE BY THE CONTRACTOR IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SITE DISTURBANCE. SAID PAD SHALL BE UNDERLAIN WITH A SUITABLE SYNTHETIC FILTER FABRIC. THE PAD SHALL MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING 14. CONDUIT OUTLETS AND CATCH BASIN INLETS MUST BE PROTECTED PRIOR TO START OR FLOWING OF SEDIMENTT ONTO PUBLIC RIGHT-OF-WAYS. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE OR ADDITIONAL LENGTH AS CONDITIONS OF CONSTRUCTION. EROSION 8c SEDIMENT DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. 15. THE CONTRACTOR SHALL PROVIDE A DETAILED SEQUENCE OF CONSTRUCTION ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. UPON COMPLETION OF CONSTRUCTION ACTIVITIES, OPERATIONS FOR REVIEW AND SUBMITTAL TO THE O N T R O L DETAILS THE AREA USED FOR TRACKING PAD SHALL BE RETURNED TO ELEVATIONS 16. THE CONTRACTOR SHALL MEET THE ENGINEER ON -SITE TO DEFINE THOSE AREAS AND CONDITIONS WHICH EXISTED PRIOR TO THE START OF CONSTRUCTION. WHICH WILL REQUIRE SOIL EROSION AND SEDIMENT CONTROL FACILITIES, DISCUSS THEIR CONSTRUCTION AND THEREAFTER PROVIDE DETAILED PLANS FOR REVIEW OF SUCH FACILITIES BY THE ENGINEER, THE AND THE REVIEWED AND APPROVED BYI MIKE HETCHKISS, FLA, P,E, No,39514 DIAN RIVER COUNTY DEPARTMENT OF 1840 25th STREET SEBASTIAN PHASE 2 D 19 vERo � 07j' S6j7A -80 0 32960 UTILITY SERVICES WATER ASSESSMENT PROJECT 21 cn PROVIDE TRENCi-,. SLOPE AS REQD.:--r GRADE APE -ON T rEr T 7 CITE w DETECTUIN TAPE. SEE NOTE 16' MAX. LAYERS OR OTHER APPROVED MAINTAIN TRENCH METHOD TO ACHIEVE WIDTH E'--Dr ABOVE 95*/ COMPACTION TOP LrrPIPE f SEE NOTE 4 MAXIMUM WATER LEVEL ,,--4' MAX, ALLOWABLE DURING LAYERS CONSTRUCTION AT 95*/ _ 1 3/4' DIA. BEDDING ROCK ,P-'PIPE OR PEA ROCK WHEREUNDISTURBED '� CONDITIONS REQD, �l RE CH AkDTH 7vll'__ SOIL. N G T E 1- ------ SDIL 04 CrNDIT1S CANNOT BE MAINTAINED AS SHOWN AB13 VE, PROVIDE APPROVED METH13D (IF CONSTRUCTMN. 2. SKETTM4G Wf:,, -.1 BE REQUIRED AS DETERMIWD IN THE FIELD. a COMPACTMN PERCENTAGES SHOWN REFER TO AA.SJ-0,0. T-Ift 4. MECHANICAL COMPACTMN NOT ALLOWED BELOW THIS LEVEL, TRENCH 'vi-IPTH 'V' = PIPE O,A PLUS 21-01, 2' WIDE IDENTIFICATION TAPE (NON-METALLIC) TO BE ATTACHED TO PIPE, TAPE TO HE MARI(ED - WATER. LINE, FORCE MAIN OR REUSE, TRACL WIRE SHALL BE. ADDED CONTINUOUS:LY ON ALL PtPL, (SEE DETAIL M-16) 7, ALL RESTORATION IN EASEMENTS OR RIGHTS OF WAY OR WHEN REQUIRED BY OTHER JURISDICTIONAL AGENCIES IT SHALL CONFORM TO COUNTY UTILITIES SPECIFICATIONS OR THE OTHER jURjSDTCTIUNAL AGENCY SPECIFICATIONS, WHICHEVER IS KURE STRINGENT, (UNPAVED AREAS) TRENCH DETAIL WAWDC Na M-1 ASPHALT SURFACE FINISHED GRADE, 36' SQUARE —A F 24' SQUARE 40 (1) Na 30 5 0 CONTIN CONCRETE ONE (1)� NO. 30 PAD CONTIN, SLIDE TYPE �ASE BOX SLIDE TYPE VALVE WX TYPE I TYPE II POLYETHYLENE - (VISGUEFENIR13N STAY -PUT COVER OR EQUIVALENT)\ RAISED LETTERS MARKEDt WATER* AS APPLICABLE OR 24' MAX. 'SAN. SEWER4 AS APPLICABLE L TYPE TYPE 11 PROVIDE EXTENSrON A'S N11TE_L.___ L SEE TRACER WIRE DIE TIAL, i E)QSTTNG i BASE TRENCN WIDTH IV' + 4' NIR SURFACE RESTORATION MECHANICALLY MIN, SAW EXISTING PAVEMENT REPLACEMENT SEE NOTE 6 LIMEROCK BASE IN 3 LIFTS AT 6' MAX LAYERS OR 98% OTHER APPROVED��� METHOD TO ACHIEVE c� 95X COMPACTION 4' MAX, --- , __u! MAX WATER LEVEL ALLOWABLE DURING LAYERS -% "mcv ONSTRUCTION D. 3/4' DIk RED DING P T12. PIPE OR PEA ROCK, WHERE _tLlp_F- 1 12, CONOITIMS REQUAIE O.Dl 7fll�"_UNDISTUPBED SOIL TRENCH WIDTH iii NOTES I, WHERE SOIL CONDITIONS CANNOT BE MAINTAINED AS SHOWN ABOVE, PROVIDE APPROVED METHOD OF CZIRSTRUCTION, 2, SHEETING WILL BE REQUIRED AS DETERMINED IN THE FIELD. 3- NEW &!_PFACI?4G MATERIALS SHALL BE CONSISTENT WITH EXISTING AND SHALL HAVE LAPPED AND FEATHERED JOINTS. (I-I/Z' KIN. THK.). 4- C COW-Al-YION PERCFNTAGES SHOWN REFER TO AASKT,a T-IM 5, ALL ROADVAY RESTORATION SHALL COMPLY WITH INDIAN RIVER ('_3jWT'f PUBLIC VORK� / F.D.O.T. STANDAP-US.. 6, MECHANICAL CONPACTIM NOT ALLOWED BELOW THIS LEVEL 7. TRLNCH WIDTH IV' - PIPE EM PLUS 2'-V, ti WIDE IDENTIFICAT1.0s, rAPF_ (N1N-04ETALLAC) T13 BE ATTA04ETJ PIPL, TAPE -10 BE AARKED - WATER LINEFORCE MAIN OR REUSE. TRACE WIRE SH&L BE ADDED CONTINUOUSLY ON ALL PIPE (SEE DETAIL M-16 DRAWING (PAVED AREAS) N° TRENCH DETAIL M-2 24' X 24' X 6' THICK CONCRETE PAD AT EACH VALVE BOX WITH (1) - NO, 3 0 CONTTNUOUS, (SHALL BE 36' X 361 IF LOCATED IN TRAFFIC WAY.) FINISHED GRADE—-, Ri ! lip, caC cNCAsEmENT 61 NIK XTVM DJTSIDE DIAMETERS OF PIKmas EVE C T I OL-L-- UTILITY OTHER TNlAN SEVER SAMIT SEWER CONCRET E OCASEMENT cumc� C4CAXMENT Lw_mv MIX WATER MAIN WATER MAIN WATERLINE TO bE OVER TOb OF SEWERLINE WHERE POSUELL A mj 6 ENCASEMENT DE"ll-AILS KM NOTES lg L USE ENCASEMENT WHERE VERTICAL CLEARANCE e.ETVEZN WATER MAIN & SEVER IS LESS THAN IS INCHES, DlJC-,lLv D�GN PIPE MAY BE USED IN LIEU OF CONCRETE ENCASEMENT AT WATER'LINE. CROSSING WITH A LENGTH OF PIPE CENTERED AT THE POINT OF CROSSING, SO AS TO LOCATE JOINTS AT A MAXIMUM DISTANCE FROM THE WATER LINE. 2, MAINTAIN 16' HORIZONTAL DISTANCE BETWEEN WATER MAIN AND SEWER AS A MINIMUM 3. WHERE A 101 MINIMUM DISTANCE CANNOT BE MAINTAINED, BOTH LINES ii SHALL BE 01P. WITH MECHANICAL JOINTS OR CONCRETE ENCASED ITS ENTIRE LENGTH, 4. WHEN THERE IS A CONFLICT BETVEEN A STORM SEVER PIPE (OR SANITARY SEVER PIPE) AND A WATER MAIN (OR FORCEMAIN) THE WATERLINE (OR FORCEMAIN) SHALL OF CLASS 52 DIP. OR CONCRETE ENCASED. 11 Na Ul-ILITY ENCASEMENT M-31 AIR RELEASE VALVE ?' DIAMETER STAINLESS ST OR BRASS NIPPLE 2' STAINLESS DOUBLE STRAF SERVICE SARI WATER MAIN 1/21 01-vZ AND FITTINGS 2' DIAMETER STAINLETS STEEL 13R BRASS NIPPLE 2' BRASS CURB STOP NOTES > 11 AUTOMATIC AIR RELEASE VALVE TO BE LOCATED ONLY WHERE L) CONDITIONS MAKE IT INACCESSABLE OR AS REQUIRED BY THE a U, S. 2AIR RELEASE. RISERS TO BE IN A VERTICAL POSIT113N AND PLACED AT SUMMITS IN THE SYSTEM, 3. AIR RELEASE VALVE TO BE INSTALLED AEUVE SURROUNDING GRADE PER, D. E, P. NOTES 4. 'SCE TRACER WIRE DETAIL., 1, VALVE BOX LID SHALL BE PAINTED BLUE FOR, WATER AND YELLOW FOR FORCE MAINS. - I I MAW LW, Nm VALVE BOX PAD VALIVE AND BOX m INDIAN RIVER COUNTY 1840 25th STREET VERO BEACH, FLORIDA 32960 (407) 567-8000 (AUTIWTIC - WAfEW / SE)wTR) ABOVE CR01-IND AIR RELEASE VALVE DETAIL 70-- to 1* 0 0 L 4- Z 0 C5 a cv -J, 4J a 16 o a t t c L z 4) it 16 0 U d 44 LLJ OA 0-c +1 cx L -a Ts L 0 L � 140 vi 50 61 M �cx CF & RESTRAINING SCHEDULE AND NOTES !M--5B I TRAM ww is feamm cm ALL PIPE, 2- INCt" ALL CM W WE%%. & LA" 94 PNCE OF PM 3. CONTRACTOR RESPOM" FM OONTOMY OF ALL W4CE WWW- ARE TU BE HOT $MOO= (aO/50 RM9 ON110. WW W/3 ALTDOOMM LAYEAS OF SCOTCH *3r TAPE & 00k" WW 800104 wAT9"wd)0F*4 006WAX*m� & S~ ow moky BE %m baTm OF SCOTCH WKW & VERFICAnON OF SX*W- 0 RMWJM LV0N COWPIr" OF 00WXrNL)rinM M PUT CowniojoLls y%*%a L04DER NW. FOW LOOMEN THEN aw r WN� wwww sw 31e OF MAN 41wkw emT. I Tww, 2 WNE 4" OF 6%04�N WIROERr E. - AFIWRY43M r TRACE WIRE AROUND THE 8Xr 5 WK 5 wows 1 ==tm=0x IID "Vols SOMLOER BRANCH SPLICE DETAIL r NIM GRADE ww MXR eat WE DiTAOL AJOVE , 00k7*m^x #14 DOW $a*" 00NDUCTOR ♦4' 00pPETmw" OBSTRUCTION 36' KIN. COVER RESTIA PRESSURE MAIN IV4ED S W7 TS OR 22 1/2* ENCASE AS REOWD. DS (M,il) SPECIAL ITILITY CROSSING - FITTING TYPE IS' MINIMUM CLEARANCE REQUIRED FOR WATER, STORM WATER, AND SANITARY SEVER MAIN CROSSINGS. 111P, WITH MECHANICAL .DINTS OR CONCRETE ENCASEMENT IS REQUIRED IF MINIMUM CLEARANCE CANNOT BE OBTAINED. GRADE SLOPE TO OBSTRUCTION—,, 36- MIN. COVER---' SEE NOTE NO. 2✓ PRESSURE MAIN C' IOR ACCEPTARL DEFLECT113N TFUL t LENGTH ENCASE AS REQ'D.J KP N % rpo AT CROSSING C30 STANDARD UTILITY CROSSING - DEFLECTION TYPE NOTES 1. THE DEFLECTION TYPE CROSSING SHALL BE USED WHEREVER POSSIBLE. ONLY LINDER SPECIFIC ORDERS BY THE ENGINEER SHALL THE FITTING TYPE CROSSIING BE ALLOWEM 2, CONSTRUCT STANDARD CROSSING NOT TO EXCEED 75X [IF THE MANUFACTURE'S MAXIMUM J13INT DEFLECTION. a IF USED, TIE RODS ARE TO BE COATED WITH A COAL TAR ENAMEL AFTER ASSEMBLY, (2 COATS MINIMUM.) 4. OTHER METHODS OF RESTRAINT MAY BE USED AS APPROVED BY lJkC.D.Uls. 5, USE ENCASEMENT WHERE VERTICAL CLEARANCE BETWEEN WATER MAIN & SEVER IS LESS THAN IS INCHES, DAP, WITH MECHANICAL JOINTS MAY BE USED IN LIEU 13F CONCRETE ENCASEMEENT AT WATER LINE CROSSING WITH A LENGTH OF PIPE CENTERED AT TW POINT 13F CROSSM, SO AS TO LOCATE JOINTS AT A MAXIMUM DISTANCE FROM THE WATER LINE, 6SEE TRACER WIRE DETAIL - TmT6 UTILITY CROSSING`-3 ASBUIL T 00 9' PLUG + R+ ):�0ZL 4.68 NOTEi A MINIMUM TEXT SIZE OF 1/8' MIA 8' /- ASBUILT S' P.V.,R-6 rURKS SHALL BE REQUIRED ON ALL d io/ STA. 0+37 ASBUILT SURVEY'S. 7w T.O.P. RL. 4.40 R/W — ------ 4__ Do or -- ASBUILT 9' 90* BEND I 7' STA, 0+ gZ TTATT Lw Cmawyn ;n me a tm F.O.P. XL. 4,42 AXt&l& ASBUILT S' FORCE MAIN PAVEMENT + ASBUILT 8' 22 112' BEND Jr.M. UYDZR V 11E z STA, f+16 .X r.O.P. 1& &44 (04 SrA. 123+ f 8 (18N L) ox ASBUILT S' 22 l/2*BENI) F.Y.EWDZR SAN. S. AIR RELEASE STA. f + 22 T.m, T.0,P. JAL. 5.50 VALVE OVZR W.47. T.O.P. 9L 6.52 SAY. S.T.O.P. fl6.4a7 SrA. I + se ASBumr A.R.V. TAP rm. fo.p. RL SAS STA. f +28 ASBUILT 8 SLEEVE STA, 122,25 (18- LSTT) x PIV, T.O.P. ZL. 5.32 R- 114 TURD CORNER STA. 2+ 75 OF BLDG. F.Y. VNDRR R/W Tilt. r.OA RL. 6.36 co 'cou 710 rRL ZLI 6.25 + + R/W mwl Lac I Or —T— 121+00 122+00 1123+00 a, SAN. &— NOTES \jXS—SLqLlF 9, ------- _QLLIulwi� R-4 T S P�V�, L nWJOM PPJ*7M SHOWN A=E REPRESENTS TEE miNimum INFORMATION STA. 122+ 74 TO BE PROVIa BY THE. ?6s3/cOw"hCTUR's SURVEYOR AlTOs IRCDM aam IMANxIAS3UtLslam 'chSDUI"LT T. 0,P, ZL. 4.40 ffibrhflw9.1wpyAhmRle &RIS UIAT 13R LATEST, IF A CAM SYSTEM IS Hot ORIGINAL ASDUILr% SHALL FURNISH" AM PILL K SCZ*1 K 4AN AlJtOCAD9 *13 FM744AT NY IRCDUS FOR DI&ITMALTY!W A FEE STRUCTURE 13 AVAILABLE At THE OFFICE (IF INDIAN RIVER OF UTTL SERVICM (SEE "IBA, Miall & 1419C FIR ASSUILT/CONSTRUCTION REQUIRE140(M) _r IL STATIONING 13F ITEMS TO K (IN THE 9WlN?r^MI I-PTEP" 1 1"PsASA K"rkWNW mTAT?lmNGATTrE' &TAIR EEERF�ALY"Y" AS CONSTRUCTION PROCEED& 4, CONTRACTOR TO INDICATE THE SIZE, TYPE, DIRECrION AND HLOWER Or TURNS TO CLOSE EACH VALVE 5S. CONTRACT13R TO PROVIDE NAME OF BUSINESS OR RESIDENCE, STREET ADDRESS AM TAX L D. WMER FOR ALL PROPERTIES ADJACENT TO LINE EXT0410M 4& AMILT UTILITY LINES SHALL BE SHOWN WITH A VIDER SOLID LINE EXISTING UTILITY LINES SHN.LVE SN0WN WITH A 7141M DASHED LlW_ MVING (EXAMPLE) ANO. ASBUILT DRAWTN G M - 17 J. i REVIEWED AND APPROVED BY; MICHAEL C, HOTCHKISS, FLA, P,E, No, 39514 TECHNICAb BLANKEN D A, T JlULY " I L_ DEPARTMENT OF SEBASTIAN PHASE 2D SHEEI DESIGNED BY: SCALE, 2 UTILITY SERVICES APPROVED BY, MICHAEL C, HOTCHKIS:, C13UNTY PROJECT NO. UW-97-13-DS WATER ASSESSMENT PROJECT 21 r 9 CARRIER PIPE CALL 2a'-i?' RESTRAINED) (TYP) 2'-6' S`-0' S`-0' 1'-0' 21-6' CASING INSULATOR WITH RUNNER HEIGHT TO BE LARGE ENOUGH. SO THAT IT DOES NOT INTERFERE WITH THE PIPE RESTRAINED JOINTS. CASING INSLATOR BY CASCADE WATERWORKS MFG, 13R EQUAL, STAINLESS STEEL NUTS 6 BOLTS STEEL .CASING PIPE CARRIER PIPE NOTES i. NUMBER GF INSULATORS AS PERMANUFACTURERS' SPECIFICATIONS. WAVING (BLOCKING DETAIL) M JACK AND BORE M-13 P,E. GOOSENECK 3' LOW (MIN.) 13R SWING JOINT OR APPROVED EQUAL BY IRCDUS LOCKING CLRB STOP (TO ACCMRMODATE METER MM S 5/8' x 3/4' METER) OR 2' 5' g' ROA dAY 5'-V FrIERGLASS STOP � . , •I I � FINISH GRADE--� CL : IN LIME DUAL. I LING S RVICE CHECK BY IRCDUS ST METERS STAINLESS STEEL SERVICE (SEE N13TE 6) D13UBLE STRAP SERVICE SADDLE FITTINGS '-'—WATER MAIN AS REQ'D. N01 ES 1, SUCCESSIVE TAPS INTO THE WATER MAIN SNA.LL BE R MINIU£M{ OF 18' ON CENTER, 2. SHORT SERVICES AND LONG SERVICES REQUIRE 36' MINIMUM COVER, WITHIN RIGHT-OF-WAY, 3. MINIMUM SERVICE SIZE NOT LESS THAN V, DUAL SERVICES SHALL BE A MINIMUM 1-1/2' AND TRIPLE SERVICES SHALL BE A MINIMUM 2', QUADRUPLE SERVICES SHALL BE AS APPROVED BY IRCDUS. 4. V & 1-1/2' LONG SERVICES REQUIRE A 2' MIN. I.D. CASING PIPE, 2' LONG SERVICES REQUIRE A 3' MIN. I.D, CASING PIPE, CASING PIPE SHALL BE SCH 40 P.V.C. 5, METERS GREATER THAN 2 INCHES SHALL BE MANUFACTURED BY HERSEY, MASTER OR APPROVED EQUAL BY TIME IR,CMI, DEFT. of UTILITY SERVICES AND SUPPLIED BY APPLCANT. METERS 2' AND SMALLER SHALL BE SUPPLIED BY IRCDUS, 6, PIN LOCKS SHALL BE PURCHASED BY THE DEVELOPER AND/OR CONTRACTOR AND SHALL BE INSTALLED INN ALL LOCKING CURB STOPS, SAMPLING PRINTS, AND WATER SERVICE CONNECTIONS AT THE TIME OF ACTIVATING ALL WATER MAINS OR AT SUCH TIME AS DIRECTED BY IRCDUS. 7. CURB STOPS SHALL BE THE SAME SIZE AS THE METERS THAT ARE INSTALLEM S. METER BOXES SHALL BE EXTENDED INTO PRIVATE PROPERTY IN CASES WHERE PLACING WITHIN RIGHT-OF-VAY WOULD RESULT IN OBSTRUCTING FLOW PATH OF SWALE. LOCATE METERS MIN. 2' OUTSIDE BOTTOM OF SWALE I WATER SERVICE W--4 0 DUCTILE IR13N TO EXTEND DUCTILE IR13 N M.J. ONE LENGTH MINIMUM CLASS 52 PIPE CARRIER PIPE SIZE STEEL CASING MINI" WALL THICKNESS 4' I2' Ace 6' 14' 2W 8' 16' 2W IV EO' zM 12' 24' 250 16' 32' .375 20' 40' .375 24' "1 .SDO 3V 61Y .625 36' 72' 42' W 625 4e' 96' .525 NOTE, IF RETAINER GLANDS ARE REQUIRED. THE CASING SIZE SHALL BE ADJUSTED ACCORDINGLY. CASING° INSTALLATION M-14 DETAILS 5' ROADWAY 5' PAVING ®-ROCK BASE "'1B STILE I104 M4J• CLASS 52 PIPE •-•-- METERS SHALL BE METERS SHALL BE LOCATED IMMEDIATELY LOCATED IM9EDIATELY INSIDE THE RIGHT -OF -VA, INSIDE THE RIGHT-OF-WAY UNLESS OTHERWISE MESS OTHERWISE DIRECTED BY IRCDUS DIRECTED BY IRCDUS < SEE NOTE 8, DETAIL W-4) t SEE NOTE 8, DETAIL W-4 ) 1 1/2 ' PE LOCKING SERVICE LATERAL CURB ST13PS ALL DRILL R BORE SMALL BE EXTENDED 5' FROM EWE OF PAVEMENT. DRILL BORE '°� 1 INSTALLATION M-14 DETAILS METER BOX (METER HEST SMCWN) 1' P.E. SERVICE LATERAL BRASS C13WRESSMN WYE BRANCH -i IN LINE DUAL. BRASS PLAN- VIEW CHECK BY IRCDUS IOF2 NG CURB STOP TURD LLER) WITH INTEGRAL METER COUPLING a. CENTER OPENING OVER METER(S) 1' MIN. CUSTOMERS METER PIPING (BY OTHERS) BOX S N13TENEL oar 3) CV)OR 4' MIN. GRAVEL-- CRUSHED ROCK CROSS SECTION NOTES 1. METERS OVER 2' MUST BE APPROVED BY LR.C.DILS, AND INSTALLED BY CONTRACTOR. 2. ALL METERS 2' AND S14ALLER WILL BE SUPPLIED AND INSTALLED BY I,R.C.DAIS, 3. MINIMUM SIZE OF METER BOXESs V SERVICE C12' X 201)1 1-I/2' AND 2' SERVICE (17' X 28'1 4, METERS NEATER THAN 2' SMALL BE MASTER METER OR COMPOUND AS REQUIRED AND APPROVED BY I.R.C,D.U.S. INDIAN RIVER COUNTY 0 1840 25th STREET • s VERO BEACH, FLORIDA 32960 (407) 587-8000 c TIVE -- ROAD MAIN UN DER F.H. ci j ROAD �,�VALVES SHALL SE LOCATED ADJACENT TO TEE +-1q'*--- INDICATE DISTANCE FROM RIGHT OF WAY (TYP.) NOTES 1. VALVES SHALL BE LOCATED SO THAT ONLY 3 VALVES ARE REQUIRED TO ISOLATE ANY 2 RESIDENTIAL OR 1 COMMERCIAL BLOCK. 2, VALVE SPACING ON WATER HAM SHALL NOT EXCEED 10W MAXIMUM. 3. A MIN. COVER OF 36' IS REQUIRED ABOVE BELL OF W1 AND P,Y.C, PIPE. 4. CONTRACTOR IS RESPONSIBLE FIN* THE INSTALLATION 13F BLUE REFLECTIVE MARKERS INDICATING FIRE HYDRANTS, I PIPE INSTALLED UNDER PAVEMENT SHALL SE D.LP., AND SHALL EXTEND 5 FEET BEYOND EITHER SIDE CIF" PAVEMENT. P.V.C. MAY BE USED BELOW ENTRANCE ROADS AND PARKING LOTS, IF INSTALLED WITH A MINIMUM OF 42' COVER, 61 DEAD END LINES, VALVES, AND HYDRANTS SHALL BE RESTRAINED, 7. ALL LINES MINIMUM 10' OFFSET PRIOR BUILDINGS. DRAWDifs (VALVE AND FIRE HYDRANT) LOCATION DETAIL W-1 A CORPORATION STOP SHALL BE INSTALLED WITH A LENGTH OF V COPPER TUBING EXTENDING ABOVE THE GROLt& THE TUBING SHALL BE INSTALLED WITH A 180' BEND, V GATE VALVE I' COPPER TUBING GRADE - °r N WI WWW s CORPORATI13N STIR WITH P.Vr- PLUG WHEN ABANDONED ° WATER MAIN NOTES 1. TEMPORARY SAMPLING PAINT MAY BE CONSTRUCTED OF ALTERNATE MATERIALS AS APPROVED BY IRCDUS, DRAVM (BACTERIOLOGICAL N4 TEMPORARY SAMPLING POINT W--6 DEPARTMENT OF UTILITY SERVICES is ^' n.`. • C `,' � op_-Iw soft - DIRECT CONNECTION (ANCHOR 6' PIPE III RI I. HYDRANT GUARDS TO BE 4' DIAMETER GALVANIZED STEEL 13R DUCTILE 74M PIPE FILLED w/ CONE. GUARDS M BE PAINTED SAME AS HYDRANT. 2, IL OF THE PUMPER CONNECTION SHALL BE Ilr MM ABOVE THE DF THE NEAREST ROADWAY OR FINISH GRADL 3 COAT TIE RODS WITH COAL TAR EN/dEL AFTER ASSEMBLY C2 COATS MW 4, ALL HYDRANTS SMALL BE TRAFFIC BREAKAWAY TYPE. AMERICAN- DARLING B-84-•B.,FUJiER 4423 OR CL13V MEDALLION F2345. 5. ALTERNATE METmaD OF RESTRAINING HYDRANT NAY BE USED IF APPROVED BY IRCDUS (E.G. TIE RODS OR MEGA LUGS) 6, COMPLETE ANCHORED FIRE HYDRANT ASSEMBLY MAY BE UTILIZED IN LIEU OF ABOVE. 7, FIRE HYDRANT SHOULD BE LOCATED WITHIN i2' FROM EDGE OF PAVEMENT WHERE POSSIBLE, DRAWING FIRE HYDRANT DETAINS W-2 j- FESCO 805Y DEL. CK. 2' SCH 40 GALV. (TYPI) 17' or 'Wye' (TYP.) PRESSURE GAUGE 2' METER SEE NOTE 10 (TYP.) w 2' SERVICE EXISTING GRADE 18' MAX SADDLE 12' MIN > 1 N.J,G,v. Q 221 CORD, STOP 4 NEW W.M, '---TIE-IN VALVE TO BE CLOSED AND LOCKED. �EXISTING WATER MAIN ccCL��� TTa .at'au 1, TIE-IN VALVE SHALL BE OPERATED BY COUNTY PERSONNEL ONLY AND IN THE PRESENCE OF THE ENGINEER OF RECINM 2, LIMES TO BE FLUSHED SHALL BE GREATER THAN 6' IN DIAMETER, DRAVM TEMPORARY NCL 1 JUMPER DETAIL ---1 GRADE ROADWAY GRADE (SWALE) CONCRETE PAD '. , ►�..• •..es •..♦ �, THICK W/ ill KIM, No. 30 CONT. 2' LOCKING CURB STOP W/ P.V.C. PLUG APPROVED • ,` METER BOX FITTINGS y • • . 12' MIN. I.D. 2' CORPORATION STOP ' s• • • • • •s `• 1 CF. 3/4' GRAVEL OR RESTRAINED PLUG CM.JJ . ' . • • CRUSHED ROCK • • 2' POLYETHYLENE J J. I ORUMTAL DISTANCE.J MR COVER ." EIm QUAL TO DEPTH �;;i_i;�• Jar � j i; ��/,; j�i J•� ' METE POURED •'�eA;: ♦'�!`.i �` '_�..ti•��y TO xV NOTES soa �`:� ;`'," �x: �•M�t.wauD L. COAT ALL EXPOSED THREADS WITH COAL TAR ENAMEL BEFORE BACKFIIl. a°� 2. THRUST BLOCK WIGHT EQUAL TO PIPE DIAMETER. 3, BLOV-OFF TO BE LOCATED AT ALL DEAD END LINES, AS REQUIRED BY LR,C.D.U,S. 4, ECLIPSE NO. 85 M3 MW-OFF AS MANUFACTURED BY JIM C, KUPFERLE FOUNDARY CHI., ST. LOUIS, MC. MAY ALSO BE USED, 5. THRUST BLOCK DIMENSIONS SHALL BE AS APPROVED BY THE. IRCDUS, ALTERNATE METHODS QF RESTRAINT MAY BE USED AS APPROVED BY IRCDUS, BRAVING M 2" BLOW —OFF W-3 NOTES, L A ttrporary t err connectAon Is required at all cortnectioms' between axis active rater mans nnot proposed new rater man ir+Mmrwvenan 2. The Temporary Jumper dwtalt (W-iM Is to be used for fithp rem water rqn of any size From the ex>:tt� active water and for the fttng of new mans up t0 6 diameter (2.5 FPS Wro*j 4 velocity) and for putthp bacter okoalcal samples from from any new water male of any she 3. The ,) n er• c=w*cthon shall be maintained untA after the fRLkng, ffiiushhg, test:2 and disinfection of the new main has been successfully compielt and cttarance for use from the FUr4da Department of Environmental Protection CF DEP) and other Pertinent &asrvckx has been received Adtquats *Must 6kxJdng and/or restraints shall be provided 'temporal-Ky, as required. 4. Pipe and fittings used for correcting *he new p1pe to the txlstng pips shall be disinfected prbr to Von In accordance whthn AWWA C&% 1992 jijil5C The tappkV steeve and the exterior of the man to be tapped shall be dsnfected by spraykv or swabbing per Section Two of AWWA C631-92. 5. The Jumper connection shall also be us" to maintain a mh•#sum pressu^e of EO PSI In the now mans contkvwonnly after disinfection arxi until F.D.EP clearance letter is obtained 6. The Contractor shall Wvvlde documentation deronstratng that tot daubte chtcic bncicftow �x'evention device k n good worldnp order at the time of meta ation and provide doarsen*ation t the. double check backflar prevention device has been tested and Is In VWorder oat year from hs*attation by a quaUfled back fft�ooww as appro3red by Indian River C x&ity`s Utility Engineer. 7, Except as required to Plush tines W water than 6' diameter, the Uw-1n valve shall remain dossed and shall be locked In the ctosed positlon by the company. The tie-n valve shall remain lacked dosed until the new system has been cleared for use by F97 and all other pertinent ,guides. S, Upon receipt of dearonce for use from FDEP and all otter pertinent . jumper the Contractor sh&U remove the temporary rre cwThe corporation stops are to be closed and plugged with 2' brass stops. R Atl kv tallatlon and malntenance of the temporary jumper correction and associated backfkrw prevention device, ftttWQS valves, etc.. shalt be the rtsparnsRwtMty of the Contractor. ICI, If the water make to be ft n"d Is tar grr than 6' dametar or such length that a Pull pipe flush at the 2.5 FPS velocity cannot be occompUshtd, the P l*Uowk(a procedure siatt be utlllzed o Instaa pressure • gauges as kukated on detail (W-MA). b) Open all downstream valves n the new system prior to Flush c) Flush new water man thru tie -In valve ranta"V a 10+ PSI pressure differenthal between gauges during flush d) Tkrn valve shall be operated by county personnelin of the enak"tor Of record, to net t*ha the requhee pressure differential Is mokrtoked TEMPORARY Na JUMPER DETAIL W-12 NOTES (B) REVIEWED AND APPROVED BY-. MICHAEL C, HOTCHKISS, FLA, P,E, No, 39514 TECHNICAL, BLAPRKEN DAM DULY 99 EET SEBASTIAN PHASE 2 D �"� SCALEn 21. DESIAPPROVED BY, MICHAEL C• H�TCHKISS C13}NTY PROJECT NO, UW-97-13-DS WATER ASSESSMENT PROJECT OF 21 •f�1'