Loading...
HomeMy WebLinkAbout2016 Airport Roof Framing Plan (Box 3 #76)Builder Contractor Responsibilities Drawing Validity - These drawings, supporting structural calculations and design certification are based on the order documents as of the date of these drawings. These documents describe the material supplied by the manufacturer as of the date of these drawings. Any changes to the order documents after the date on these drawings may void these drawings, supporting structural calculations and design certification. The Builder/Contractor is responsible for notifying the building authority of all changes to the order documents which result in changes to the drawings, supporting structural calculations and design certification. Builder Acceptance of Drawings - Approval of the manufacturer's drawings and design data affirms that the manufacturer has correctly interpreted and applied the requirements of the order documents and constitutes Builder/Contractor acceptance of the manufacturer's interpretations of the order documents and standard product specifications, including its design, fabrication and quality criteria standards and tolerances. (AISC code of standard practice Sept 86 Section 4.2.1)(Mar 05 Section 4.4.1) Code Official Approval - It is the responsibility of the Builder/Contractor to ensure that all project plans and specifications comply with the applicable requirements of any governing building authority. The Builder/Contractor is responsible for securing all required approvals and permits from the appropriate agency as required. Building Erection - The Builder/Contractor is responsible for all erection of the steel and associated work in compliance with the Metal Building Manufacturers drawings. Temporary supports, such as temporary guys, braces, false work or other elements required for erection will be determined, furnished and installed by the erector (AISC Code of Standard Practice Sept 86 Section 7.9.1) (Mar 05 Section 7.10.3) (CSA/S16-09 Section 29). Discrepancies - Where discrepancies exist between the Metal Building plans and plans for other trades, the Metal Building plans will govern. (AISC Code of Standard Practice Sept 86 Section 3.3) (Mar 05 Section 3.3) Materials by Others - All interface and compatibility of any materials not furnished by the manufacturer are the responsibility of and to be coordinated by the Builder/Contractor or A/E firm. Unless specific design criteria concerning any interface between materials if furnished as a part of the order documents, the manufacturers assumptions will govern. Modification of the Metal Building from Plans - The Metal Building supplied by the manufacturer has been designed according to the Building Code and specifications and the loads shown on this drawing. Modification of the building configuration, such as removing wall panels or braces, from that shown on these plans could affect the structural integrity of the building. The Metal Building Manufacturer or a Licensed Structural Engineer should be consulted prior to making any changes to the building configuration shown on these drawings. The Metal Building Manufacturer will assume no responsibility for any loads applied to the building not indicated on these drawings. Foundation Design The Metal Building Manufacturer is not responsible for the design, materials and workmanship of the foundation. Anchor rod plans prepared by the manufacturer are intended to show only location, diameter and projection of the anchor rods required to attach the Metal Building System to the foundation. It is the responsibility of the end customer to ensure that adequate provisions are made for specifying rod embedment, bearing values, tie rods and or other associated items embedded in the concrete foundation, as well as foundation design for the loads imposed by the Metal Building System, other imposed loads, and the bearing capacity of the soil and other conditions of the building site. (MBMA 06 Sections 3.2.2 and A3) BUILDING DESCRIPTIONS I Building ID Width Length Height Slope Building A 16'-8 16'-8 10'-015 2:12 Building B 22'-6 16'-8 10'-94 2:12 2"0 A325 BOLT GRIP TABLE GRIP LENGTH BOLT LENGTH NOTE.• 0 TO F T. 1 9116 114 " FULL THREAD ENGAGEMENT IS DEEMED TO HAVE BEEN MET Over 9116 " TO 1 1 /16 " 1 3/4 " F T. WHEN THE END OF THE BOLT Over 1 1 /16" TO 1 5/16 " 2" IS FLUSH WITH THE FACE OF THE NUT. Over 1 5/16 " TO 1 9/16 " 2 114 " Over 1 9 f 16 " TO 1 13/16 " 2 1 /2 " WASHER REQUIRED ONLY WHEN SPECIFIED. Over 1 13/16 " TO 2 1 /16 " 2 3/4 " GRIP WASHER MAY BE L OCA TED UNDER HEAD OF BOL T, UNDER NU T, OR A T BO TH A T LOCATIONS OF BOLTS LONGER THAN 2 3/4" LOCATIONS NOTED ON ERECTION DRAWINGS. NOTED ON ERECTION DRAWINGS ADD 5/32" FOR EACH WASHER TO MATERIAL FT DENOTES FULLY THREADED THICKNESS TO DETERMINE GRIP. For questions regarding the interpretation of the drawings, materials provided, or assembly of the parts: • Call 1-800-879-7827 and ask for the "Field Service" department. • Before or after normal hours, you may send an email to OKCSField.ServiceOStarBuilding s.net. Please include the order no., brief description of the question, & contact name and phone number. ENGINEERING DESIGN CRITERIA Building Code 2014 Florida Building Risk Category Normal (Risk Category II) Roof Dead Load Superimposed 2. 20 psf (Bldg A) 2. 16 psf (Bldg B) Co l latera t ..... . .. . . ......... 5. 00 psf ( to ldg A, B) (5,00 psf Other) Roof Live Load 20.00 psf no reduction Wind Ultimate Wind Speed (Vu l t) . , . 160, 00 mph Nominal Wind Speed (Vasil) .... 123 mph ( I BC sect i on 1609. 3. 1) Wind Exposure Category C Internal Pressure Coef (GCp i) 0. 18/-0, 18 Loads for components not provided by building manufacturer Corner Areas ( w i th i in 3, 00' of corner) 51. 07 psf pressure -68. 09 psf suet i on Other Areas 51,07 psf pressure -55,32 psf suction These values are the maximum values required based on a 10 sq ft area. Components with larger areas may have lower wind loads. DEFLECTION CRITERIA The material supplied by the manufacturer has been designed with the following minimum deflection criteria. The actual deflection may be less depending on actual load and actual member length. BUILDING DEFLECTI❑N LIMITS...: BLDG-A,B Roof Limits Rafters Purlins Panels Live L/ 180 150 60 Snow L/ 180 180 60 Serviceability Wind L/ 180 180 60 Total Gravity L/ 120 120 60 Total Uplift L/ N/A N/A 60 Frame Limits Sidesway Live H/ 60 Snow H/ 60 Serviceability Wind H/ 60 Seismic Drift H/ 40 Total Gravity H/ 60 Service Seismic H/ 40 Wall Limits Limit Total Wind Panels L/ 60 Total Wind Girts L/ 90 Total Wind EW Columns L/ 120 The Service Seismic limit as shown here is at service level loads. PROJECT NOTES Material properties of steel bar, plate, and sheet used in the fabrication of built-up structural framing members conform to ASTM A529, ASTM A572, ASTM A1011 SS, or ASTM A1011 HSLAS with a minimum yield point of 50 ksi, Material properties of hot rolled structural shapes conform to ASTM A992, ASTM A529, or ASTM A572 with a minimum specified yield point of 50 ksi. Hot rolled angles, other than flange braces, conform to ASTM 36 minimum. Hollow structural shapes conform to ASTM A500 grade B, minimum yield point is 42 ksi for round HSS and 46 ksi for rectangular HSS, Material properties of cold -formed light gage steel members conform to the requirements of ASTM A1011 SS Grade 55, ASTM A1011 HSLAS Grade 55 Class 1, ASTM A653 SS Grade 55, or ASTM A653 HSLAS Grade 55 Class 1 with a minimum yield point of 55 ksi, For Canada, material properties conform to CAN/CSA G40, 20/640, 21 or equ i va lent, Alt bolted joints with A325 Type 1 bolts are specified as snug -tightened joints in accordance with the Specification for Structural Joints Using ASTM A325 or A490 Bolts, December 31, 2009, Pre -tensioning methods, including turn -of -nut, calibrated wrench, twist -off -type tension -control bolts or direct -tension -indicator are NOT required. Installation inspection requirements for Snug Tight Bolts (Specification for Structural Joints Section 9.1) is suggested. Using 5X5 eave gutter with 4 x 5 downspouts, the roof drainage system has been designed using the method outlined in the MBMA Metal Building Systems Manual. Downspout locations have not been Located on these drawings. The downspouts are to be placed on the building sidewalk at a spacing not to exceed 16 feet with the first downspout from both ends of the gutter run within 8 feet of the end. Downspout spacing that does not exceed the maximum spacing will be in compliance with the building code, The gutter and downspout system as provided by the manufacturer is designed to accommodate 10 in/hr rainfall intensity. Design criteria as noted is as given within order documents and is applied in general accordance with the applicable provisions of the model code and/or specification indicated, Neither the metal building manufacturer nor the certifying engineer declares or attests that the loads as designated are proper for local provisions that may apply or for site specific parameters, The design criteria is supplied by the builder, project owner, or an Architect and/or Engineer of Record for the overall construction project. This project is designed using manufacturer's standard serviceability criteria. Generally this means that all deflections are within typical performance limits for normal occupancy and standard metal building products. This metal building system is designed as enclosed, All exterior components (i , e. doors, windows, vents, etc.) must be des i gned to withstand the specified wind loading for the design of components and cladding in accordance with the specified building code, The framing at building B, gridlines 1, 2 is N❑T designed to receive a future bay addition, Corresponding frame reactions are calculated based upon actual tributary area. Framed openings, walk doors, and open areas shall be located in the bay and elevation as shown in the erection drawings. The cutting or removal of girts shown on the erection drawings due to the addition of framed openings, walk doors, or open areas not shown may void the design certifications supplied by the metal building manufacturer. Roof and wall panels have been designed in accordance with section 2222,4 of the Florida Building Code, Fifth Edition (2014). Product approval numbers for the State of Florida, Department of Community Affairs per Product Rule 9B-72: 1, Roofing Products FL11868 PBR 26 gauge roofs This jobsite is located in a hurricane prone region with wind speeds of 130 mph or greater, In order to maintain the enclosed classification and design for wind all doors, windows and wall mounted light transmitting panels (LTP) provided by the metal building manufacturer shall be protected by impact resistant coverings. The material may include but is not limited to 7/16 structural wood panels as proscribed by the local building code. The customer's Design Professional, not metal buiLoling manufacturer engineer, is responsible for determining the adequacy of material acting as the impact resistant covering by others and attachment to the material provided by the metal building manufacturer. This structure has not been designed to withstand the additional internal pressure required by Code as a partially enclosed condition in the absence of impact resistant coverings, Investigation of the existing structure for possible detrimental effects due to the metal building addition is not within the metal building manufacturer's scope of work, It is strongly recommended that the original designer or other responsible professional be retained to analyze the existing structure, recommending any reinforcement that may be needed. The metal building manufacturer and its certifying engineer expressly exclude the existing structure for any warranty or certification whether written, verbal or implied, The manufacturer is not responsible for the deflection compatibility between the material provided by the manufacturer and the existing by others. Tie-in by flashing only Longitudinal bracing loads are not to be transferred between the material provided by the manufacturer and the existing construction by others, v MCI a a Yo Q. r o > o _ o 0 0 U L m = O � o U J Q � a U d o U U Q) z � L W o z z Q Q ® ❑ U F- ~ F- V) � (n 1aCL o m LLJmo`Ld �s ✓ V) Q cn D O U U 0 �U o o� L� L z ago �� CLA Lo 1.2 � F- Q ❑ ❑ o' i- imam; z o � ilk w LLi UJ e Q~) U z z Of Q (/} E o °' o w m UJ Z _J c) _J III cJ az:�E Scale: NOT TO SCALE Drawn by. JOM 3/18/16 Checked by: GAS 3/18/16 Project Engineer. DJR Job Number: 15-B-20726 Sheet Number. E1 of 5 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer is not the overall engineer of record for this project. Brian A. Carmichael, P.E. Florida P.E. 67645 DRST1 B ENSi1 A. 4c- v S WC EWB KEY PLAN EWp S WC SWA am Wn ed� 0 J W W F-- U) W O O O CD i IN N 16'-0 16'-8 OUT❑UT OF STEEL ROOF FRAMING PLAN b Cg J W W Cn W O O O J W W F_ Cn W O F_ D O O Q0 i N N __8 to] ROOF SHEETING PLANE 1 PANEL TYPE = PBR (GALVALUME) PANEL OVERHANG = 3" FROM OUTER STEEL I I I I I I SIN �KV �-iN KN _IN rIN o� a7 07 CD I I I ( I I I ROOF SHEETING PLAN f v b 0 C p v o o � o � o t: o rn O O m O L m = b J O p o U Q U a o J a O v U_ V Ij z L L Q) D o Z Q Q ® ❑ U Ulf!? u- � < < p m m ( €-� cn Q fn ! maco ti �U oU _ U as O L O � LZ oZ U ❑ ❑ Q Z O -J W LL_ �i ° W z Er_ Ea D > O c w m W U � J W � Scale: NOT TO SCALE Drawn by JOM 3/18/16 Checked by: GAS 3/18/16 Project Engineer: DJI' Job Number 15-13--20726 Sheet Number. E2 of 5 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer is not the overall engineer of record for this project. Brian A. Carmichael P,E, Florida P.E. 67645 DRST1 D ENST1 A e ; ''ice C ATE GE A i� SWA (H.S.) v z LL LL a L a F� 4" r---------------------------------� FIELD ATTACH EAVE STRUT (NOT BY MANUFACTURER) OPEN TO ROOF LINE FOR CONSTRUCTION (NOT BY MANUFACTURER) 16'-0 11 4" ELEVATION "SWC" BUILDING "A" 4" 11 16'-0 ELEVATION "SWA" BUILDING "B" 0 4" . I ( 16'-0 ELEVATION "SWC" BUILDING "B" a ff M M r � D o CL- fl 0 > Q o d°' v cti O O v� rn ¢ x M K) 0 o U3 C ,O U p m = ci J o o O U J Q a- O j d C� U W B_ A J LLJ o o z z z a Q ~� ® ❑ z U to 0 Ui `` �Q0-Q if} O M ry m Li LLJ r CL Cn Q V1 O O Q) U LJ __J ) C C `q 12L`p Z It L? � ❑ ❑ ry 2 O J U LL- 0 2 C) LJ Lil O LU a z Q 1 C/) C O Lo J0 P- LLI Z3 t� JC7iJ Q�� O Scale: NOT TO SCALE Drawn by.- JOM 3/18/16 Checked by: GAS 3/18/16 Project Engineer DJR Job Number: 15®-8-20726 Sheet Number. P 3 of 5 The engineer whose sea! appears hereon is an employee for the manufacturer for the materials described herein, Said seal or certification is 'invited to the products designed and manufactured by manufacturer only.The undersigned engineer is not the overall engineer of record for this project. Brian A. Carmichael, P.E. Florida P.E. 67645 DRSTIB ENSTIA t- SPLICE BOLT ICONN.I QTY. SIZE TYPE A (2) 2 X 14 A325 B&N TABLE HARDENED BEVELED WASHERS WASHERS 0 0 ..ATE Of SPLICE BOLT TABLE CONN. QTY. SIZE TYPE HARDENED BEVELED WASHERS WASHERS A (2) X 1 A.325 B&N 0 0 v F C D s u L -9� 0 r 12 2'-4 4'-0T' 4'-01 4'-0J I ~ I = i FIELD ATTACH w IN "m EAVE STRUT & PURLINS = TO CMU WALL > (NOT BY MANUFACTURER) w rn I 0 16'-8 OPEN TO ROOF LINE TO REMAIN OPEN 22'-6 OPEN TO ROOF LINE TO REMAIN OPEN 22'-6 Cb d) ELEVATION "EWB" BUILDINGS "A" & "B" C� w w Q w I 0 ELEVATION "EWB" BUILDINGS "A" & "B" 12 2 4 -0J 4'-01s 2'-4 1 2'-3M I i I FIELD ATTACH I EAVE STRUT & PURLINS TO CMU WALL j (NOT BY MANUFACTURER) I I I I I I I I I I I IN v 0 0 �r r Y O Q, 0 d U N Q cI X pq 0 0 �0 m r a O Y v a:O 'C 'O b J O <t J W U Z O Z -J E O Z Z Z Q Q U to (n �4�Q om�m LLJ Cn<tEn C� z U <t Q' Z o J U L- w u_i U Z Q O CII m III J U W v QZ:2 Scale: NOT TO SCALE Drawn by JOM 3 f 18 f 16 Checked by.- GAS 3/18/16 Project Engineer; DJR Job Number: 15—B-20726 Sheet Number, E4 of 3 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer is not the overall engineer of record for this project. Brian A. Carmichael, P.E. Florida P.E. 67645 Ia DRSTIB ENSTIA h-..yTE OF OY/PROJECTS\XD j—V5-11-00 FRAME = Active/ENG/15—B-20726/ver01—DJRhoades/Bldg—B/Drftg/x01 L OY/PROJECTS\XD`,—V5-11-00 FB SET = Eng/15—B-20726/ver01—DJRhoades/Bldg—B/DRFTG/x01L GENERAL NOTES FRAME CLEARANCES SHOWN ARE APPROXIMATE AND MAY VARY DUE TO CONDITIONS (DEFLECTION). 3/18/16 14:10:27 v N VERTICAL CLEARANCE DIMENSIONS ARE FROM FINISHED FLOOR REFERENCE ELEVATION. 4 A 0 84 3'-211 3'-3�,, 12 22'-6 OUT/OUT OF STEEL CROSS SECTION AT FRAME LINES "1 "& "2" 4'-0A 4'-0J a IN I- 0 w w Q w Co I sxf W ' C ,O o J o < J q- C Z D J :�E LL. o z z z <�a U cn v1 �Qala o marm LIJQ Li cnQcn U Q z o U --� u- w LLT UJ C 0 In W J C) —J i U Q Z � Q Scale: NOT TO SCALE Drawn by,- JOM 3/18/16 Checked by.- GAS 3/18/16 Project Engineer: DJR Job Number: 15-13-20726 Sheet Number: E5 of 5 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer is not the overall engineer of record for this project. Brian A. Carmichael, P.E. Florida P.E. 67645 DRSTIB ENSTIA z SPLICE BOLT TABLE CONN. QTY. SIZE TYPE HARDENED BEVELED WASHERS WASHERS A (8) 4 X 14 A325 B&N 0 0 A—' a &'., ATE 4l