HomeMy WebLinkAboutFIRE RE-INSPECTION - 510 Crossings Blvd 2023CITY OF HOME OF PELICAN lAAND RDR-0D1r vcrM FNr FOIE FREVEN w OR 1225 HM! &- (7M • sEW7 FAX FLORD)A 3255E 1F.IPPIIONL (rr2) EP9SOr FAx (rr2) $Pi-i$fe Date 03/24/2023 Fire Inspection Report Inspector Contact: Sandy Seeley 873-3179 Sseeley@cityofsebastian.org Occupancy Name Veta's We Care LLC Address 510 Contact Name Occupancy Type Residential Board and Care Phone -n arD FL 32958 Email NOTICE OF FIRE AND SAFETY HAZARDS: You are hereby notified that an inspection of your premises has disdosed the following fire hazards and/or violation of standards of the National Fire Prevention Association (NFPA) adopted by The Florida Fire Prevention Code. As such conditions are contrary to law, you are hereby required to correct said conditions upon receipt of this notice. A re -Inspection to determine compliance will be conducted on or after the scheduled re -Inspection date. Failure to comply with the forgoing order before the date of such re -Inspection may render u liable to thepenalties provide b law for such violation. VIOLATIONS FIRE SYSTEMS PRESENT ' Alarm Sprinkler Hood Standpipe Fire Pump Generator Each bav/unit shall be identified by 6-in numbers for letters, contrasting color, visible from the roadway, at front and rear exits. Knox entry system required; Type/location Truss signage required; Type/location: Yes: Type/Location: Yes: Box: _ Switch ELECTRICAL ❑2A Extension cords use is not allowed in lieu of permanent wiring. Location(s): ❑2B Remove all storage within 3 feet of electrical panels. Location(s): ❑2C The use of non -listed multi -plug adapters are not allowed. Only UL listed type (surge type). ❑2D Breakers in the electrical panels must be legibly marked indicating their purpose and/or area of service. 112E All wiring shall be protected in approved conduit. ❑2F Open wire splices are required to be in a junction or receptacle box with a cover plate. ❑2G Electrical panel must have voids filled with approved spacers. ❑2H Wiring is damaged. Replace or properly repair. Location(s): EXITS 03A Install or repair exit and/or emergency lighting. Location(s): 03B Door is not functioning properly. Location(s): ❑3C Exits shall be free of furnishing, decoration, or other objects that obstruct exit access and/or visibility thereof. ❑3D Fire exit hardware shall not have additional locks, latches or devices that inhibit its function or are not listed/approved. ❑3E Secondary exit door has an improper lock. Deadbolts shall not require the use of a key from the inside of the building. ❑3F Enclosed stairs shall be prohibited for use of any type of storage. No storage is allowed under or within 10It of exterior stairs. F�RF.EXTINGUISHERS A Provide service or inspection by a state licensed company for all fire extinguisher annually. 114B Extinguishers are required to be properly mounted along an exit access with the top no higher than 5 feet. ❑4C Fire extinguisher(s) required. Provide _ extinguisher(s) of a 2A10BC minimum rating per NFPA 10. GENERAL AND STORAGE ❑5A Compressed gas cylinders/tanks shall be stored, appropriately secured, and identified with the product name. ❑58 Fire S,ystem�needtcorrections: Q _ � � u-c — — .--� cot — Compliant Da 4 Inspector: