Fire Inspection Report
Inspector Contact: Sandy Seeley sseeley@cityofsebastian.org874-3179
Date i / Inspection Type Annual Fire Inspection
Occupancy Name Ay Jalisco Occ. Type Assembly/Restaurant
Address 1814 US #1 Sebastian, FL Phone 388-2368
Contact Name Vickie
Email
NOTICE OF FIRE AND SAFETY HAZARDS: You are hereby notified that an inspection of your premises has disclosed the following fire hazards
and/or violation of standards of the National Fire Prevention Association (NFPA) adopted by The Florida Fire Prevention Code. As such conditions
are contrary to law, you are hereby required to correct said conditions upon receipt of this notice. A re -inspection to determine compliance will be
conducted on or after the scheduled re -inspection date ( ). Failure to comply with the forgoing order before the date of such re-
insoection may render you liable to the oenalties Drovide by law for such violation.
I VIOLATIONS FIRE SYSTEMS PRESENT UAlarm USprinkler MHood LStandpipe LFire Pump LGenerator I
ADDRESS
01A Each bay/unit shall be identified by 6-in numbers for letters, con
tI asting color, visible from the roadway, at front and rear exits.
* ❑18 Knox entry system required; Type/location (�EV�lIP t �t Yes: Box: —Switch
❑1C Truss signage required; Type/location: Yes: Type/Location:
ELECTRICAL
❑2A Extension cords use is not allowed in lieu of permanent wiring. Location(s):
❑28 Remove all storage within 3 feet of electrical panels. Location(s):
❑2C The use of non -listed multi -plug adapters are not allowed. Only UL listed type (surge type).
❑2D Breakers in the electrical panels must be legibly marked indicating their purpose and/or area of service.
❑2E All wiring shall be protected in approved conduit.
❑2F Open wire splices are required to be in a junction or receptacle box with a cover plate.
❑2G Electrical panel must have voids filled with approved spacers.
❑2H Wiring is damaged. Replace or properly repair. Location(s):
EXITS 'yq�o�
3A Install or repair exit and/ore er enc li htin ation(s): 11K L� I 6�
8 Door is not functioning properly. Location(s):
❑3C Exits shall be free of furnishing, decoration, or other objects that obstruct exit access and/or visibility thereof.
❑3D Fire exit hardware shall not have additional locks, latches or devices that inhibit its function or are not listed/approved.
❑3E Secondary exit door has an improper lock. Deadbolts shall not require the use of a key from the inside of the building.
❑3F Enclosed stairs shall be prohibited for use of any type of storage. No storage is allowed under or within 10 ft of exterior stairs.
FIRE EXTINGUISHERS
114A Provide service or inspection by a state licensed company for all fire extinguisher annually.
❑4B Extinguishers are required to be properly mounted along an exit access with the top no higher than 5 feet.
❑4C Fire extinguisher(s) required. Provide _ extinguisher(s) of a 2A30BC minimum rating per NFPA 10.
GENERAL AND STORAGE
05A Compressed gas cylinders/tanks shall be stored, appropriately secured, and identified with the product name.
❑5B Fire, Systems need corrggtions: _ L I f _ 1^ _
Compliant Date: / /
Inspector: