HomeMy WebLinkAboutFIRE ANNUAL 2023 FOR 695 SEBASTIAN BLVD. FOOD TRUCKCITY OF sTIAN HOME OF PELICAN ISLAND BUILDING DEPARTMENT FIRE PREVENTION OFFICE 1225 MAIN STREET • SEBASTIAN. FLORIDA 329 TELEPHONE (M) 559-5537 FAX (M) W 25W Date 6, Occupancy � Address L Fire Inspection Report Inspector Contact:Y��(See`e� 5Se e Contact Name t e,Z n V �—,Q r1 g—keZEmail ca� i l ptR:�-OD ( (Ji? • CCr1l NOTICE OF FIRE AND tKFETY AZARDS: You are hereby notified that an inspection of your premises has disclosed the following fire hazards and/or violation of standards of the National Fire Prevention Association (NFPA) adopted by The Florida Fire Prevention Code. As such conditions are contrary to law, you are hereby required to correct said conditions upon receipt of this notice. A re -inspection to determine compliance will be conducted on or after the scheduled re -inspection date. Failure to comply with the forgoing order before the date of such re -inspection may render you liable to the penalties provide by law for such violation. VIOLATIONS FIRE SYSTEMS PRESENT ❑ Alarm ❑ Sprinkler ❑ Hood ❑ Standpipe ❑ Fire Pump Generator ADDRESS ❑ 1A Each bay/unit shall be identified by 6-in numbers for letters, contrasting color, visible from the roadway, at front and rear exits. ❑ 1B Knox entry system required; Type/location Yes: Box: _ Switch ❑ 1C Truss signage required; Type/location: Yes: Type/Location: ICAL Extension cords use is not allowed in lieu of permanent wiring. Location(s): ❑ 2B Remove all storage within 3 feet of electrical panels. Location(s): ❑ 2C The use of non -listed multi -plug adapters are not allowed. Only UL listed type (surge type). ❑ 2D Breakers in the electrical panels must be legibly marked indicating their purpose and/or area of service. ❑ 2E All wiring shall be protected in approved conduit. ❑ 2F Open wire splices are required to be in a junction or receptacle box with a cover plate. ❑ 2G Electrical panel must have voids filled with approved spacers. ❑ 2H Wiring is damaged. Replace or properly repair. Location(s): _ EXITS ❑ 3A Install or repair exit and/or emergency lighting. Location(s): ❑ 3B Door is not functioning properly. Location(s): ❑ 3C Exits shall be free of furnishing, decoration, or other objects that obstruct exit access and/or visibility thereof. ❑ 3D Fire exit hardware shall not have additional locks, latches or devices that inhibit its function or are not listed/approved. ❑ 3E Secondary exit door has an improper lock. Deadbolts shall not require the use of a key from the inside of the building. ❑ 3F Enclosed stairs shall be prohibited for use of any type of storage. No storage is allowed under or within 10 It of exterior stairs. FIRE EXTINGUISHERS ❑ 4A Provide service or inspection by a state licensed company for all fire extinguisher annually. ❑ 4B Extinguishers are required to be properly mounted along an exit access with the top no higher than 5 feet. ❑ 4C Fire extinguisher(s) required. Provide _ extinguisher(s) of a 2A10BC minimum rating per NFPA 10. GENERAL AND STORAGE ❑ SA Compressed gas cylinders/tanks shall be stored, appropriately secured, and identified with the product name. ❑ 513 Fire Svstems.need corrections: r Compliant e: S )cc 5 Inspector: