Fire Inspection Report
Inspector Contact: Sandy Seeley sseeley@cityofsebastian.org 874-3179
Inspection Type Fire Inspection
Occ. Type Resaturant
Address 9615 US #1, Sebastian, FL 32958 Phone 388-0048
Contact Name 2� eV(C�iiS Email vl {rl 3C���imQ1 r
NOTICE OF FIRE ANdd SAFETY- HA R hereby notified that an inspection. of your premises has disclosed the following fire hazards
and/or violation of standards of the National Fire Prevention Association (NFPA) adopted by The Florida Fire Prevention Code. As such conditions
are contrary to law, you are hereby required to correct said conditions upon receipt of this notice. A re -inspection to determine compliance will be
conducted on or after the scheduled re -inspection date 1 ). Failure to comply with the forgoing order before the date of such re -
I VIOLATIONS FIRE SYSTEMS PRESENT UAlarm USprinkler UHood LlStandpipe LlFire Pump LlGenerator I
Each bay/unit shall be identified by 6-in numbers for letters, contrasting color, visible from the roadway, at front a rear exits.
Knox entry system required; Type/location Yes: Box: —Switch
Truss signage required; Type/location:
Yes: Type/Location:
rIELECTRICAL
.C112A Extension cords use is not allowed in lieu of permanent wiring. Location(s): P, ✓ lAOOP. r
' IL—JT2B Remove all storage within 3 feet of electrical panels. Location(s):
12C The use of non -listed multi -plug adapters are not allowed. Only UL listed type (surge type).
❑2D Breakers in the electrical panels must be legibly marked indicating their purpose and/or area of service.
❑2E All wiring shall be protected in approved conduit.
❑2F Open wire splices are required to be in a junction or receptacle box with a cover plate.
❑2G Electrical panel must have voids filled with approved spacers.
❑2H Wiring is damaged. Replace or properly repair. Location(s):
EXITS
❑3A Install or repair exit and/or emergency lighting. Location(s):
❑3B Door is not functioning properly. Location(s):
❑3C Exits shall be free of furnishing, decoration, or other objects that obstruct exit access and/or visibility thereof.
❑3D Fire exit hardware shall not have additional locks, latches or devices that inhibit its function or are not listed/approved.
❑3E Secondary exit door has an improper lock. Deadbolts shall not require the use of a key from the inside of the building.
❑3F Enclosed stairs shall be prohibited for use of any type of storage. No storage is allowed under or within 10 ft of exterior stairs.
FIRE EXTINGUISHERS
❑4A Provide service or inspection by a state licensed company for all fire extinguisher annually.
❑4B Extinguishers are required to be properly mounted along an exit access with the top no higher than 5 feet.
❑4C Fire extinguisher(s) required. Provide _ extinguisher(s) of a 2A10BC minimum rating per NFPA 10.
�_ENEDALAND STORAGE
�1
r5Ampressed gas cylinders/tanks shall be stored, appropriately secured, and identified with the product name.
e,/Systems Jueed corrections:
NOTES: 1 1 Y P_CX 0) G S Z i.
Compliant Date: _J--/.
Inspector:
�I\