HomeMy WebLinkAboutRE-INSPECTION Vics Pizza 1140 US 1 5-23CITY OF
SEB.ASTj A 1\T
HOME OF PELICAN ISLAND
BUILDING DEPMTi
FlBE PREVENTION OFFICE
122E MAIN& (772) • i9 W? F N. rM SIM 32Nk
11:LL'PFIONf: 1]Td)SP9�553] FAx (]]2j 5B9�25bb
Date G
Occupancy Name Vic's Pizza
Fire Inspection Report
Inspector Contact: Sandy Seeley sseeley@cityofsebastian.org 874-3179
Address 1140 US #1, Sebastian, FL 32958
Inspection Type Fire
Occ. Type Assembly/Restaurant
Phone 589-8989
Contact Name 'fdfl Rue)G elrI Email �� i CSIDI LZ4 I� 12 C VYIadIlGko
NOTICE OF FIRE AND SAFETY HAZAR ou are hereby notified that an inspection of your premises has disclosed the following fire hazards
and/or violation of standards of the National Fire Prevention Associati n (NFPA) adopted by The Florida Fire Prevention Code. As such conditions
are contrary to law, you are hereby required to correct said o Iti s receipt of this notice. A re -inspection to determine compliance will be
conducted on or after the scheduled re -inspection date ailure to comply with the forgoing order before the date of such re -
VIOLATIONS FIRE SYSTEMS,PRESENT LlAlarm LlSprinkler MHood LlStandpipe LlFire Pump LlGenerator
ADDRESS w' ui:11i• `v 1' 1. t C £ liif, L' Tlfl' fdS �a'�W ❑1A Each bay/unit shall be identified y inn tubers or letters, con rasti co Is e m the roadway, at front an
❑1B Knox entry system required; Type/location i�c 0�1 l� L9 Yes: Box: _ Switch
❑1C Truss signage required; Type/location: Yes: Type/Location:
ELECTRICAL
❑2A Extension cords use is not allowed in lieu of permanent wiring. Location(s):
❑2B Remove all storage within 3 feet of electrical panels. Location(s):
❑2C The use of non -listed multi -plug adapters are not allowed. Only UL listed type (surge type).
❑2D Breakers in the electrical panels must be legibly marked indicating their purpose and/or area of service.
❑2E All wiring shall be protected in approved conduit.
112F Open wire splices are required to be in a junction or receptacle box with a cover plate.
❑2G Electrical panel must have voids filled with approved spacers.
❑2H Wiring is damaged. Replace or properly repair. Location(s):
rIw
rear exits.
EXIT
hd 3A Install or repair exit nd/o mergency lighting. Location(s): \\\
ffr❑3B Door is not functioning properly. Location(s):
RLp3C Exits shall be free of furnishing, decoration, or other objects that obstruct exit access and/or visibility thereof. C � p
3D Fire exit hardware shall not have additional locks, latches or devices that inhibit its function or are not listed/approved. �%%�i� _
❑3E Secondary exit door has an improper lock. Deadbolts shall not require the use of a key from the inside of the building. OC' � (L,SI/J
❑3F Enclosed stairs shall be prohibited for use of any type of storage. No storage is allowed under or within 10 fit of exterior stairs.
FIRE EXTINGUISHERS
❑4A Provide service or inspection by a state licensed company for all fire extinguisher annually.
❑4B Extinguishers are required to be properly mounted along an exit access with the top no higher than 5 feet.
❑4C Fire extinguisher(s) required. Provide_ extinguisher(s) of a 2A10BC minimum rating per NFPA 10.
GENERAL AND STORAGE
❑5A Compressed gas cylinders/tanks shall be stared, appropriately secured, and,..ipde�ntitilfieed with the-,,7{roduFt na e � I 1
❑5BFirZtgmAneedcorrections: --1�' 11 A�� ✓le PC.I r IQU�I�fi. It ?��
NOTES:'1 C Y� � C C/. a V1,eo VYlOf'� �-e-i-,
Recipient:
I