Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CORRESPONDENCE FILE 3
Memorandum To: COMMUNITY DEVELOPMENT From: GINNY SIEFERD ENVIRONMENTAL TECH. Date: 10/26/12 Re: DOLLAR GENERAL No comments Siqns and Pavinq Sidewalk should connect to CR512 Sheet 4 #912" lineal lines along walk way By #8 alternate entrance from CR 512 right and left turn arrows are needed Environmental No comments /gs Dorri Bosworth From: Wayne Eseltine Sent: Thursday, October 25, 2012 8:51 AM To: Dord Bosworth Subject: Dollar General Sorry for the delay. The Building Department has no objections to the site plan for the Dollar General building at 9200 Sebastian Blvd. Wayne Eseltine, CBO Building Director City of Sebastian 772-388-8235 DL NEEL- SCHAFFER S-1—i— Y —, b-il.1 am MEMORANDUM TO: Dorri Bosworth, city of Sebastian Community Development Dept. FROM: Frank Watanabe, Consultant Engineer, Neel -Schaffer, Inc. I Wife-01 (01 A41#1 OF R P 14 rZIM F 161 VrATJ Fa I I Le M I a 1.72 P, I a WA ud 0M 1014r. I I L01 I L*111017TY11kLo Plan sheets comments 1. Cover sheet - redo or add a readable location map to show the site of the project at CR 512 and Sebastian Crossings Blvd. 2. Sheet 3, 4 and 5, the site plan needs to be revised to show the existinq east side accem road reafiqned with existino west side drivewav to the north (see oaqe 3 - Example) 3. Sheet 3 — The legend show proposed the silt fence as a dash lane pattern, but the plan does not show the dash line on the sheet — need to show the silt fence line, 4. Sheet 3 - Shows a construction note for a DS-3 for new Type C inlet, but there is no DS-3 note shown on the plans. 5. Sheet 3 - Note 9 refers to surface drainage to flow toward the outfall structure. Where is there an outfall structure? Modify this note. 6. Sheet 3 - The SWPP needs to match the local SJWMD requirements for handling the storm water run-off and any dewatering during construction. 7. Sheet 4 - Why change the existing driveway entrance radius? Is it need for truck turning - Per note 2 - driveway needs to be shifted to the north to realign with the eastside road, 8. Sheet 4 - As noted the existing driveway needs to be relocated north to align with the eastside access road, 9, Sheet 4 — If the driveway is not relocated, then the access will be restricted for right turn in and out of the proposed site. A median island be constructed along Sebastian Crossing t* restrict the left turns from accessing the site 10. Sheet 4 - Need to show the internal trucking turning template to show truck movement along the back loading area. 11, Sheet 4 — The pavement section noted in the detail sheet needs to be changed to SP (super pave asphalt) per FDOT asphalt standard, 12. Sheet 4 - What is meant by heavy duty pavement? Need to provide detail of this typical section with SP asphalt. 13. Sheet 4 — For note 5 regarding integral curb and sidewalk, revise to show Type D curd adjacent to the sidewalk 14. Sheet 4 — All notes need to refer to FDOT standard plans and details for traffic painting, markings and signage. 15. Sheet 4 — Since the internal aisle is considered an access street, the street needs to show continue striping to ensure the travel lanes. 16. Sheet 4 — At the far west intersection/corner of the site and access street, need to provide striping of the triangle area to delineate the travel lane 17. Sheet 4 — Along the back side and the west side of the project site, need to restrict parking and stopping with signage. 18. Sheet 4 — Need to show sidewalk along the east side frontage of the property adjacent to Sebastian Crossing Blvd. 19. Sheet 5 — Provide the internal drainage calculations on the 15" ADS pipe as provided to SJRWMD for permit approval, 20. Sheet 5 — Need to provide the letter or correspondence from SJRWMD on the approval of the site per the original permit 21. Sheet 5 — All grates (existing or proposed) within the travel lane shall be load bearing grates and boxes 22. Sheet 5 — Where does the water go at DS-4? This appears to be a low point in the drainage system since Inv elevation is lower than DS-2. This does not flow storm water? 23. Sheet 6 — Any utility comments from IRC utilities need to be incorporated per comments from IRC utility dept. 24. Sheet 7 — Detail for stop bar will be revised with a 4 ft offset from the edge of pavement instead of the 6 ft 25. Sheet 7 — Detail on the sidewalk ramp, change max to the minimum slope is 12 to 1 for all handicap ramps per ADA requirements 26. Sheet 8 — Erosion control detail, the silt fence needs to be trenched into the ground per FDOT and SJRWMD requirement 27. Sheet 8 — All details showing asphalt pavement will be revised to show SP 12.5 for type of asphalt required by the City. 28. Sheet 8 — The detail for integral curb and sidewalk will not be used and this detailed delete, city requires sidewalk with a standard FDOT Type D curb. 29. Sheet 10 —Asphalt pavement section cross slopes shall be at a min 2% slope for drainage and not labeled as varies. . ��' •rKnr axs aer• •; • tom PAD UWACE y /•h.,._ _-�-e--M----its---- r j�' '� 0 � LOT 4 �f CL �. or 40 i w z ti t 1 i Kr• t`Q�A' •'j= +i 1:+ ifax1 _ (A6 to �pP! 11Dt1dAOW tt/OT � - �1r ME0 QY Notes : 1. THIS SURVEY DOES NOT REFLECT OR DETERMINE OWNERSHIP. f ' 2.:. LANDS.' SHOWN . HEREON WERE NOT ABSTRACTED FOR RIGHTS -OF WAY J 9R.' EASEMENTS OF RECORD. 3 Page 1 of 1 Dorri Bosworth From: Dorri Bosworth Sent: Thursday, October 25, 2012 9:39 AM To: 'Herb Green' Subject: Dollar General - Engineering Comments Attachments: doc03290120121025083506.pdf-, doc03290320121025083823.pdf Hi Herb — See attached comments. Contact information for Mr. Frank Watanabe is also attached. Regards, Dorri Bosworth, Planner Community Development Department City of Sebastian 1225 Main Street, Sebastian, Florida 32958 (772) 589-5518 (772) 388-8248 fax dbosworth@cityofsebastian.org 11/1/2012 \.r✓ yd INDIAN RIVER COUNTY DEPARTMENT OF UTILITY SERVICES INTEROFFICE MEMORANDUM DATE: OCTOBER 19, 2012 TO: JAN KING GROWTH MANAGEMENT DIRECTOR CITY OF SEBASTIAN THRU: MIKE HOTCHKISS, P.E., CAPITAL PROJECTS MANAGER FROM: JESSE ROLAND PLANS REVIEWER SUBJECT: APPLICATION FOR DEVELOPMENT ORDER SITE PLAN REVIEW FOR DOLLAR GENERAL We have reviewed the above -referenced project. The following comments must be addressed and/or incorporated prior to site plan approval: Water and sewer available, must connect. A full set of construction plans must be submitted for a Utility Construction Permit and capacity charges must be paid to guarantee capacity. Proposed size and location of water meter(s) must be indicated on plans, as well as water and sewer connections. Water and sewer services must be installed outside of paved areas (in grassed areas) and outside of courtyards or fenced areas. Line Extension Fees, Impact Fees and/or account charges must be paid for connection to water and sewer Applicant must provide building plans and description of proposed water uses. Impact fees and account deposits will be required for connection to County water and sewer, based on plans and uses. Applicant must install an aboveground, non -galvanized metallic double check valves with a reduced pressure feature on potable water service lines to prevent back -flow of contaminants associated with business into the County water system. Manufacturer and model to be approved by the County. • Fire protection may be required. Applicant should contact the Indian River County C:\Documents and Settingsljking\Local SettingATemporary Internet Fites1OLK1 ICASITE PLAN REVIEW - DOLLAR. GENERALIO-19- 12JRRJRR.doc ti+id 'gad Page 2 Department of Emergency Services at 562-2028, ext. 3001, for fire protection requirements. • If Fire Protection is required, a Utility Construction Permit must be obtained for construction of a double detector check valve that is required on the fire line. • Contractor must call for utility locations 48 hours prior to construction. Water and sewer facilities can be located through Sunshine State One at 1-800-432-4770. • Outdoor floor drains and storm drains, that collect waste that is not generated from potable water, are not allowed to be connected to the County sewer system. A set of plumbing plans must be submitted to the County for verification. Applicant must provide separate treatment system for any waste not generated from potable water. Treatment system must be permitted through the Environmental Health Department. • For your information regarding the Solid Waste Disposal District, an assessment for solid waste shall be paid at the time construction of the parcel has been completed, immediately prior to obtaining a Certificate of Occupancy. For further details, contact Donna Stark at 226-1300. • More than one parcel may not share the use of a private sewage collection system. In order to serve more than one parcel with a private system the parcels must be unified as one parcel. • Contractor must call for utility locations 48 hours prior to construction. Water and sewer facilities can be located through Sunshine State One at 1-800-432-4770. • Irrigation meters are not permitted to be connected to County water. A private well or other alternative water source may be utilized for irrigation if permitting allows. • All on -site flow wells not in use must be abandoned and plugged. St. Johns River Water Management District must be contacted regarding modification of associated consumptive use permit. Funding may be available from St. Johns for plugging wells. Contact Roland DeBlois with the Environmental Planning Department for details of well plugging program. • Any contractor constructing public underground water and sewer utilities must be a licensed Underground Utility Contractor or licensed General Contractor in the State of Florida and Indian River County. M Page 3 If you have any questions or comments, please call Jesse Roland at 226-1636 cc: W. Erik Gilson, Director of Utility Services Robert Keating, Community Development Director Stan Boling, Planning Director Lori Hoffman, Environmental HealthDepartment '. Site Plan Review for Dollar General - 9200 Sebastian Blvd Page I of I Jan King 11"W M From: Jesse Roland groland@ircgov.com] Sent: Friday, October 19, 2012 10:01 AM To: Jan King Cc: Erik Olson; Bob Keating; Stan Boling Subject: Site Plan Review for Dollar General - 9200 Sebastian Blvd Attachments: SITE PLAN REVIEW - DOLLAR GENERAL, 10-1 9-12,JRR,JRR.doc <<SITE PLAN REVIEW- DOLLAR GENERAL, 10-1 9-12,JRR,JRR.doc>> Good morning Jan, Please find the attached site plan review comment letter. Jesse Roland Indian River County Dept. of Utility Services Utilities Engineering 1801 27th Street Vero Beach, FL. 32960 Tel: 772-226-1636 Fax: 772-770-5143 C, 10/22/2012 0 1 1800 27th Street Vero Beach, FL 32960 PH: 772-226-1880 FAX. 772-978-1848 RE: Project Name: Project Description: Project Number: Application Description: Application Number: File Number: Tax ID: I. CoiiiiiiercialllirnLilti-f',iniilN- buildingsshall post a mininium 6 inch numerical address. IRCO 951.07 (3) (b) 2. 'I'Urninradius shall be 35 11. inside and 55 ft. outside Litilizing Cull pavement width. IRCO 9521 (5) (b) z:1 Z:� -e lanes and hydrant installation prior to combustibles on CombLIStible constrLICti011 I ires temporary III site. 4. All existing and proposed fire protection water lines within the bOUndarics of' or adjacent to. the site must be L shown. This shall include backilow prevention devices. fire department connections. and fire hydrants. IRCO 914.14 (14) (b) (1) Commercial or III(Alti-lamily buildinus r)ILISt have a minimum ot'a 8 inch N,\ater main to provide adequate watertlow. 5 remote 17ire hydrants shall be installcd within 500 ft. ol'the most e ote portion of any new bl-lildifl"S, IIICaSUrcd alon, () the fire track access route to the most remote building perimeter. IRCO 91�14 (14) (b) 6. The fire inspector lor this project is John Duran 772-226-1977. The release of these plans are pending payment of'Arlan review rees. The revie\� f`ce is S 250.00 If you have any questions regarding any of these matters, please do not hesitate to call me ati (772) 226-1977. Thank you for your cooperation in making our community a safe place to liv3 m Lieuyenant JohnDuran Fire Inspector/Plan Reviewer flags 1 01* 1 From: Lori—Hoffman@doh. state, fl. us Sent: Thursday, October 11, 2012 7:53 AM To: Dord Bosworth - 1 01 -1 Imm-1 III A is U� Lori Hoj' finan Indian River County Health Department 1900 27th Street Vero Beach, FL 32960 772-794-7440 ---- --- --- LEGAL DESCRIPTION stint cros",iv„ s coll"'mercial, a" perplat recordtxj in Nast &,ok 222, lliqws 73 through 76, inclusivc oftfie Public Kcalrd ol'Indian Kh-uCounty, 4,X 'SE PLANS MAY NOT BE COPIED OR MODIFIED WITliOUT WRITTEN AUSSION FROM CADJAZZ. F VALID UNLESS SIGNED & EMBOSSED BY A REGISTERED ENGFFER )JAZZ. CERTIFICATE OF AUTHORIZATION #28509 SHEET NUMBER DESCRIPTION: BY: )I,1-2,DG.SFB (DOLLARGFNFRALA,d,SEBASTIAN) '-RP i Page 1 of 1 Dorri Bosworth From: Dorri Bosworth Sent: Thursday, October 11, 2012 11:05 AM To: 'Frank Watanabe' Attachments: 20121011101608057 0001.tif Hi Frank — FBO your review of the Dollar General site plan, attached is a .tif file for the Burger King as -built showing the access road across Vani/Crossroads Plaza property connecting to Sebastian Crossings Blvd. Let me know if you need additional info from the files. Dorri Bosworth, Planner Community Development Department City of Sebastian 1225 Main Street, Sebastian, Florida 32958 (772) 589-5518 (772) 388-8248 fax dbosworth@cityofsebastian.org 11/1/2012 Dosofvwn of Burger Khe Sao � ,• � -ram.-. _ _.-- � r a r A• _ �„ O4� ---------------- lee . �.... ✓ Notes+ f. M SVRKY 0M Nor MMO OR OMMA K OaNunw. x. NdNfmat w -BSIR C M MR NCR1E NAY >. a A Na 11XMM SM •. WOaM. Aft HR M NG N0Rae04M IGr t*"A a ARMY SRS UM N Raab UK V PM row Nuavatt Mn w Ilr. raG,taOa]d (, am 1W 4• 'M I Gaw,rpxs AGNI KIRWI A" N /pT. Q3OMCI* ro Ra10•x9 gam Orl{�y{(p TSS COAfT ! rSaocTC SiRNlY' A fGa tltC. Ra1M A R.aafea tLL1arlGN a ea» rat rM J, NamMa TMrrK NORV.EMTm NORM U SAG S/U KA" Raiia'4eY ASIT SAD atAr. A M QPLCAa WG UX ar S n rROKM Ih CMAMK A /t NM MMnff R %IQaOa>.'X.'C OeAM aSTA.0 er M ARMY MMn 0D=M p GHAPFDC SCALE M taT) e wa . ao il.r P i CA 5rz MLVAW MW) a • {aM vAaas) 1 a..n.RN.w - - Ap Paving, Grading & Drainage As -Built 1 C.R. 510 Map of surrey SURVEYORS SIGNATURE & sear William B. Zentz & Associates, Inc. "" ; "`"'°" As -Built survey Pmlesalenel Surveyors &'wo,'ars i ` for Crossroads Ptaae of sebuffan a« Rwc acarwmG Rcuv aalRamG , `, „ Proposed Burger fang Site. Indian River County, Florida Rnoll,: {m> say-rssx w:prxf sa'x-!ni ( : N.I..w i ar. 1 a•rrat�� rMM �ra-ma17 Page 1 of 1 Dorri Bosworth I"W `law From: Dorri Bosworth Sent: Wednesday, October 10, 2012 8:50 AM To: 'Herb Green' Subject: RE: Sebastian Crossings Commercial Dollar General Store Hello Mr. Green — At this time I have not received any comments regarding the site plan or architectural drawings to forward you. I will keep you in the loop if any are received. Regards, Dorn Bosworth, Planner Community Development Department City of Sebastian 1225 Main Street, Sebastian, Florida 32958 (772) 589-5518 (772) 388-8248 fax dbosworth@cityofsebastian.org From: Herb Green [mailto:HGreen@cadjazz.com] Sent: Wednesday, October 10, 2012 7:35 AM To: Dorri Bosworth Subject: Sebastian Crossings Commercial Dollar General Store Dorri, Our Architect is waiting with bated breath to start the full architectural submittals, can you share if any comments related to elevations/exterior colors/lighting are forthcoming so Architect can anticipate direction and schedule. Thanks, Herb Herb Green, PE CADJA7L Cadjazz Engineering P.O. Box 450006 Kissimmee, Florida 34745 407-738-1979 Email: hgreen@cadiazz.com 11/1/2012 Page 1 of 1 Dorri Bosworth lft�w `%fe From: Frank Watanabe [frank.watanabe@neel-schaffer.com] Sent: Tuesday, October 09, 2012 4:28 PM To: Dorri Bosworth Cc: Jerry Converse Subject: Dollar General Review Dorri, Per my discussion and field review with Jerry this morning, I would like to look at relocating the existing westside driveway at Sebastian Crossing Blvd to the north to align with the eastside drive. Can you please copy me the one sheet that shows this eastside driveway into Burger King. I would like to mark-up and add as my review comment. I can pick this up on Thurs 10/11 Thanks Frank Watanabe Neel -Schaffer, Inc. (772) 770-4707 ................................................................................................................................ Frank Watanabe Senior Project Manager Neel -Schaffer, Inc. 2925B 20th Street Vero Beach, FL 32960 Phone: 772.770.4707 FAX: 772.770.4640 Website: www.neet-schaffer.com Confidentiality Note. information contained in this message along with any attochment(s) may be confidential and protected by legal privilege. This message is meant solely for the use of the individual(s) to whom it is addressed. Viewing or the use of information and ottochment(s) within this message without the expressed permission of Neel -Schaffer, Inc. is prohibited. if you are not the intended recipient of this message, Neel -Schaffer, Inc. requests you take immediate action to notify the sender of the error and that you delete this message and all attachments without modifying, copying or distributing its content. 10/10/2012 Page 1 of 1 Dorri Bosworth `M �✓ From: Don Wallace [DQW@rkmdev.com] Sent: Thursday, October 04, 2012 11:12 AM To: Dorri Bosworth Cc: Herb Green; Bill Lloyd Subject: RE: Outside Engineering Consulting Fees for Dollar General Sebastian Thank you for the info on estimated review fee cost. We have a great Engineer onboard and I am sure the comments will be minimal so we are fine to proceed. Thanks Reel Development Services LLC Donald Q. Wallace Jr. R.K.M Development Corp. 147 2nd Ave. S, Suite 400 St. Petersburg, FL 33701 phone 727-895-2150 fax 727-821-5461 cell 727-278-8917 email dgvv@rkmdev.com From: Dorri Bosworth[mailto:dbosworth@cityofsebastian.org] Sent: Thursday, October 04, 2012 9:55 AM To: Don Wallace Subject: Outside Engineering Consulting Fees for Dollar General Sebastian Hello Mr. Wallace — We received the site plan application for the Dollar General Sebastian with the missing signatures from Mr. Green yesterday. We are now in the process of dispersing the sets of plans to the jurisdictional agencies for their review and comments (Fire Dept., Utilities, etc.) We have noted the comment regarding your request for advance notice of the additional engineering consulting fees, and the need for your pre -approval. As discussed at the pre -application meeting, our consulting engineer, Mr. Frank Watanabe, P.E. of Neel -Schaffer, Inc., reviews the initial set of plans sent to him, with most emphasis on drainage and traffic, and then based on staff and amount of time spent, will send his site comments to us, and a first billing to the city. Depending if his comments require revisions to the site plan, a follow-up review may be necessary, along with a second billing from Mr. Watanabe. it would be difficult to give an exact amount of these fees, given the variables. Staff researched our last four site plans to forward you an estimate of the fees. The highest was $2,170 and a low was $1,400. While we do not want to hold up dispersing the site plan to the consulting engineer, we await your approval and acknowledgement of responsibility for the fees. Please feel free to contact me if you have questions regarding this matter 772-388-8232. Regards, Dorri Bosworth, Planner Community Development Department City of Sebastian 1225 Main Street, Sebastian, Florida 32958 (772) 589-5518 (772) 388-8248 fax dbosworthO.citvofsebastian.orr; 10/4/2012 01 t-r9&'nTffll'f 1225 MAIN STREET a SEBASTIAN, FLORIDA 32958 TELEPHONE (772) 589-5518 a FAX (772) 388-8248 www.cityofsebastion.org MEMORANDUM I)A-rE: October 1. 2012 TO: Frank Watanabe. I'll. Consulting City Engineer .lerry Converse. I'Llblic Works Director Plans Review. I.R.C. lire Dept. Jeanne Bresett, I.R.C.Trat'llic Analyst Jesse Roland, I.R.C. Utilities Lori flol'I'man. Environmental I lealth \Vayne Elseltine. Building Director Chief'Michelle Morris. Sebastian Police Dept. (iinny Sick rd. I'mironmental Technician FROM: Dorri Bosworth, Planner Community Developmefit Dept. Development Order Rcquested: Sitc Plan Approval Name ol'Pro.ject: Dollar General Location: 9200 Sebastian 11OLdeVard Lot 4. Sebastian Crossing Commercial Subdivision Please rc\ ie\\, the enclosed submittal and return your comments to me as soon as possible. Ifyou have an\ questions or need additional information. p1case contact 'lie 772-388-8232 or dbos\\,oi-th,,ii'�cit\�ot,sebastiati.or,,,. Fhank N'OLL a Page 1 of 1 Dorri Bosworth From: Dorri Bosworth Sent: Thursday, October 04, 2012 9:55 AM To: 'dqw@rkmdev.com' Subject: Outside Engineering Consulting Fees for Dollar General Sebastian Hello Mr. Wallace — We received the site plan application for the Dollar General Sebastian with the missing signatures from Mr. Green yesterday. We are now in the process of dispersing the sets of plans to the jurisdictional agencies for their review and comments (Fire Dept., Utilities, etc.) We have noted the comment regarding your request for advance notice of the additional engineering consulting fees, and the need for your pre -approval. As discussed at the pre -application meeting, our consulting engineer, Mr. Frank Watanabe, P.E. of Neel -Schaffer, Inc., reviews the initial set of plans sent to him, with most emphasis on drainage and traffic, and then based on staff and amount of time spent, will send his site comments to us, and a first billing to the city. Depending if his comments require revisions to the site plan, a follow-up review may be necessary, along with a second billing from Mr. Watanabe. It would be difficult to give an exact amount of these fees, given the variables. Staff researched our last four site plans to forward you an estimate of the fees. The highest was $2,170 and a low was $1,400. While we do not want to hold up dispersing the site plan to the consulting engineer, we await your approval and acknowledgement of responsibility for the fees. Please feel free to contact me if you have questions regarding this matter 772-388-8232. Regards, Dorri Bosworth, Planner Community Development Department City of Sebastian 1225 Main Street, Sebastian, Florida 32958 (772) 589-5518 (772) 388-8248 fax dbosworth@cityofsebastian.org 10/4/2012 10/04/2012 08:56 CITY OF SEPASTI;LN nve.idt JC/L ACCOUNT DETAIL org� 010080 Object, 533120 C0N.11UOTk141rS 001 -80-00-51-515-513120- 191actinq YEAR PER JOURNAL EFF DATE SRC T PO/.Rn-F2 REFERENCE AMOUNT P CHECK NO w,,,,Rp?tN,r VrR NAIME/ITEM DLSC cl')MS,EN`rls I I ---- :1011 ---------------------------- 12 012230 09/30/2011 API 1 ----------------------------------------------------------------------- 4186 980,00 Y 78877 10211.1 -------------------------- Neel -Schaffer NS08024-03-5 09/3 2,111 12 012103 09/20/2011 API 1 6312 4159 790.01- Y 78747 0930il Neel -Schaffer F.',ccd 2011 11 011110 08/23/2011 API 1 4134 Y 78549 090211 Neel -Schaffer Sebastiw,, Chart.er 2011 11 011106 08/22/2011 API 1 4132 140.00 Y 78504 082511 Neel -Schaffer P!�,,n Review CSIA41 :., 1) '1 : 11 0-11037 08/09/201-1 API 1 41.75 12801,00 Y 78410 081211 Newel -Schaffer ....re Kingdom Rev,i. 2011 11 011037 08/09/2011 API 1 4125 1,400,00 Y 78410 081211 Neel -Schaffer Jalisco Plan Revi noel 1.0 010GI0 07/05/2011 APII 1 "090 140.00 Y 78176 07') 8 11 Neel -Schaffer dr�veway change T 12011 08 008:4*7 05/26/2011 Spi 1 4056 280f 00 Y 77873 063311 Neel -Schaffer 04/01-04/3G CSA-1 2011 08 008002 05/02/2011 API 1 4027 560.00 Y 77695 050611 Nee2-Schaffer 03/01-133/3'/2011 '�: 0 t 1 0a 00800�1 05/02/2011 APT 1 6312 402-1 28G,06 Y 77695 050fl1 Nue I - Scs a f fer Flccd insurancv R 2011 07 007180 04/27/2011 GEN I Site Plan 490.00 Y Correct site plan 2011 06 006187 03/29/201-1 API 1 6312 3992 3,504.94 Y 77441 040811 Neel -Schaffer Flood insuranc(, R it 06 006187 03/29/2011 API 1 3992 280.00 V 77441 040811 Neel -Schaffer site plan rev7sio 2011 06 006187 03/29/2011 API 1 3992 140.00 Y 040811 Neel -Schaffer site plan revisio 2011 05 005086 02/17/2011 API 1 3:58 _j,89Q-0G Y 77017 021811 Neel-Schaffer1xnRevivw -- Tire K 2011 05 005066 02/17/2011 APT 1 3956 1 120,00 Y 77017 02i8ii Neel -Schaffer junior Charter SC 2011 05 005028 02/07/2011 API 1 6312 395i 560,00 Y 76945 021120!1 Neel -Schaffer CSP, 19 - Review a 05 00SC28 02 10-712,011 API 1 395, 210.00 Y 76945 02112011 Neel -Schaf fer Fro essional Se—v 04 004099 01120/2011 API 1 6269 3945 4,727.85 Y '76898 020411 Outlier Planning, LLC Professional Sery tit 04 004CO2 01/03/2011 API 1 6312 3928 560,00 Y 76699 010711 Neel -Schaffer C-',A IS - Review o 2011 03 003COO 12/01/2010 API 1 3912 490,00 Y 76463 120310 Neel -Schaffer Phase IT Seb RJ,,v 2(111 01 001151 10/27/2010 API 1 6269 3890 5,107.63 Y 76230 110510 Outlier I'lanning, LLC Professional Sery Total Amount: 24,210.49 ** END OF REPORT - Generated by Nancy Veidt ** cm 10/04/2012 08:56 ICITY OF SEEASTIAN JPG 1 nveidt (G/L ACCOUNT DETAIL 1glactinq Org: 010080 Object: 533120 CONSULTANTS 001-80-00-S1-515-533120- YEAR PER JOURNAL EFF DATE SRC T PO/REF2 REFERENCE AMOUNT P CHECK NO WARRANT VDR NAME/ITEM DESC COMMENTS -------------------------------------------------------------------------------------------------------------------------------------- 2012 07 027132 04/24/2012 API 1 4358 140.00 Y 80244 042712 Neel -Schaffer fema maps 2012 06 026135 03/22/2012 API 1 4318 700.00 Y 80027 033012 Neel -Schaffer Revised Site Plan 2012 06 026135 03/22/2012 API 1 4318 140.00 Y 80027 033012 Neel -Schaffer Flood Insurance M 2012 05 025113 02/22/2012 API 1 4288 980.00 Y 79778 022412 Neel -Schaffer site plan review 2012 04 024040 01/12/2012 API 1 4248 371.72 Y 79474 011312 Neel -Schaffer Services - Novemb 2012 04 024040 01/12/2012 API 1 4248 371.71 Y 79474 011312 Neel -Schaffer Review of Mulliga 2012 04 024014 01/05/2012 API 1 4246 560.00 Y 79418 020612 Neel -Schaffer Flood Insurance R 2012 03 023071 12/15/2011 API 1 4231 840.00 Y 79305 121611 Neel -Schaffer Flood Insurance R 2012 03 023010 12/02/2011 API 1 4226 700.00 Y 79249 120911 Neel -Schaffer project NS08024.0 Total Amount: 4,803.43 ** END OF REPORT - Generated by Nancy Veidt ** c Dorri Bosworth "IV, 0 Page 1 of I From: Herb Green [HGreen@cadjazz.com] Sent: Wednesday, October 03, 2012 8:19 PM To: Dorri Bosworth Cc: Don Wallace Subject: RE: Application for Dollar General - Sebastian Attachments: SEBSTM APP.pdf Dorri, Please find attached the application updated with the required signatures. We will send the originals by mail as you requested. Feel free to call me, if we can assist further. Best regards, Herb From: Dorri Bosworth[mailto:dbosworth@cityofsebastian.org] Sent: Wednesday, October 03, 2012 10:09 AM To: Herb Green Subject: Application for Dollar General - Sebastian Hello Mr. Green — I've attached the first three pages of the application form for the Dollar General - Sebastian to be completed with two missing signatures. On the bottom of page two, the application needs to be signed and notarized by the owner or representative, which based on the submitted Letter of Authorization, may be your signature. The signed section on the top of page three gives permission for members of the Planning and Zoning Commission to enter and view the property during their consideration of the application. This signature has been completed. On the bottom half of page three, a signature is needed to acknowledge that there may be additional fees for the review of the site plan by our consulting city engineer. Since this is a new site plan, the review by the consulting engineer will be necessary. Please let us know where and who a billing statement [from the city] should be sent to. The completed signature pages can be emailed back to me, and the originals mailed at your convenience. Thank you for your help with this. Regards, Dorri Bosworth, Planner Community Development Department City of Sebastian 1225 Main Street, Sebastian, Florida 32958 (772) 589-5518 (772) 388-8248 fax dbosworthe..citvofsebastian.org 10/412012 0 LI Permit Application No. MCI 1 City of Sebastian �01 Development Order Application Applicant (if not ownerLwritten authorization (notarized)/from owner is required) Namel� Address: Phone Number 2^'Z, So FAX Number. (-•tVC E-Ma . iJ Vf � �� 1 �- ?�. ! �/ t .1.) �� c �_•�Iv t Owner (if different from applicant) Name: F�A m A�I�c�,7 �s _ Address: ["}� p� ('_ I �►' \ b Phone Number ( J21) Z I&D FAX Number. E-Mail( x 15 (D 15 `7 @ A 0 b 1 Titre of permit or action requested: ' —e t�, Y otys19-Alb) ,�3'7gj__ PLEASE COMPLETE. ONLY THOSE SECTIONS WHICH ARE NECESSARY FOR THE PERMIT OR ACTION THAT YOU ARE REQUESTING. COPIES. OF ALL MAPS, SURVEYS, DRAWINGS, ETC. SHAD BE ATTACHED AND $-912' BY I V COPIES OF ANY ATTACHMENTS SHALL BE INCLUDED. ATTACH THE APPROPRIATE SUPPLEMETAL INFORMATION FORAM. A. Project Name (if applicable): f B. Site information Address: t YV Vrn e i 4 S,(z-1ivd Q) I) vd' OU16, 2.0'bMTiq n (.YQsin9 w. Lot Block: Unit: Subdivision: 4 Indian River County Parcel It �� j 36 _, Z,,,,-, Q©0 D Zoning Class's, lion: Future nd Use: Exlsdng Use: Proposed Use: C. Detailed description of proposed activity and purpose of the requested permit or action (attach extra sheets If necessary): R (. k�'�7k (AZA)�On c Q� ' l 00 sr- _1 DATE RECEIVED: '_!•2�:Jla, FEE PAID: $ I7dO - 00 RECEIVED B A EM 05 Permit Application No. D. Project Personnel: A 9nt: Name: QN� A77 Addre,*4W B. q5oo�o(p Phone Number. (40-1) -i3ib- t vi C1 FAX Number.- (qo E-Mail: 4 QJ\ Attorney: Name: Address Phone Number. FAX Number: E-Mail: Engineer: Name: 190 0A)3,h2Z- Address 9D Phone Number -(Liol -f3 4& FAX Number (L4kj-j)3qt—j GG- E-Mail: ' fte GeV i��— QAD)�2L - com Surveyor: Name. A Phone Number fol)3,52 - —119)) FAX Number: E-Mali:0-A9-YF7 RZ9 6 N A L, D 2- , M 1, BEING FIRST DULY SWORN, DEPOSE AND SAY THAT. AM THE OWNER AM THE LEGAL REPRESENTATIVE OF THE OWNER OF THE PROPERTY DESCRIBED WHICH IS THE SUBJECT MATrER OF THIS APPLICATION i THE INFORMATION, MAPS, DATA AND/OR SKETCHES PROVIDED IN THIS APPLICATION ARE AC TR TOT BEST OF MY KNOWLEDGE AND BELIEF. SIGNA DATE SWORN TO AND SUBSCRIBED BEFORE ME BY 4-4A-Vnetc+ <irzen WHO IS PERSONALLY KNOVW TO ME OR PRODUCED 'F L. Ps -- AS IDENTIFICATION, THIS 6 DAYOF ()C-h9ker NOTARY'S SIGNATURE "A !! LA PRINTED NAME OF NOTARY COMMISSION NoJExPjRAnoN HEATHERoSBORME Notary PubkState ofFWft CommM" EE 168810 My comm. expires Feb. 20,2016 140� Permit Application No. The following Is required for all comprehensive plan amendments, zoning amendments (including rezoning), site plans, conditional use permits, special use permits, variances, exceptions,, and appeals. I/WIE, — TIE OWNER(S) / : THE LEGAL REPRESENTATIVE OF THE OWNER(S) OF THE PROPERTY DESCRIBED WHICH IS THE SUBJECT OF THIS APPLICATION, HEREBY AUTHORIZE EACH AND EVERY MEMBER OF THE PLA�N�,; '--� t fit,— BOARD/COMMISSION OF THE CITY OF SEBASTIAN TO PHYSICALLY ENTER UPON THE PROPERTY AND VIEW THE PROPERTY IN CONNECTION WITH MY/OUR PENDING APPLICATION. I/WE HEREBY WAIVE ANY OBJECTION OR DEFENSE JANE MAY HAVE, DUE TO THE QUASI-JUDICIAL NATURE OF THE PROCEEDINGS, RESULTING FROM ANY BOARD/COMMISSION MEMBER ENTERING OR VIEWING THE PROPERTY, INCLUDING ANY CLAIM OR ASSERTION THAT. MY/OUR PROCEDURAL OR SUBSTANTIVE DUE PROCESS RIGHTS UNDER THE FLORIDA CONSTITUTION OR THE UNITED STATES CONSTITUTION WERE VIOLATED BY SUCH ENTERING OR VIEWING. THIS WAIVER AN 10 W. BEING SIGNED BY MENUS VOLUNTARILY AND NOT AS A RESULT ANY COERCION APPLIED, !SE 02 E P ISf R e Y EMP OR P Y EMP YEE, AGENT, CONTRACTOR OR OFFICIAL OF THE C SEBASTIAN. SI DATE Sworn to and subscribed before me byv"�' who Is personally known to meorproduced _-�-;-��� as identification, this 44 day of 20.tom. Notary's Signature Printed Name of Notary Commission NoJExpirabon Seal: Z- -TIC-= CARMWIL MYOOMMM911DI)MI EXPIRES, August 4,2013 OWN! ft W WZY swas APPLICATION FEES ARE ESTABLISHED BY RESOLUTION OF CITY COUNCIL ADDITIONAL FEES FOR THE CIT'fS CONSULTING ENGINEER REVIEW (WHEN R QUIRED) WILL BET ESPON SLIT . Y OF THE APPLICANT. pjvtse pov) 8,z_ a rl:T, C.P- -4 aUT110-1 ,fir Z5, -I /0 A6161COWI-MGMENT DATE / 1107le"05 or 007757/,PC' 'Few 540421,0 1945' 'e gAl Pevs: t'�O-;Lj A--rT-j,) , !>oA) v4-'N-LL4ce-, bQ we P-e- m j!) v - c� Indian River County Department of Utility Services 1801 27"' Street, Vero Beach, Florida 32960 Phone: 772-567-8000, Fam 772-770-5143 Herb Green. II.E., Caqjazz Fi-igineering, AwLwst 24, 2012 110 Box 450006 Kissimmee, FL 34745 Re: Comity Water & Sewer Service tkvallabillly Parcel # 3 1382200003000000004 O 9200 Sebastian Bhvd., Sebastian, Fl- 32958 Dear N—Ir. Green. Presently, public water and sewer service is imiflable to this Marcel and there Is adeqwttc plant capcity to serve fitittire development ofthis piircel, however, this does not -Liar,iritee thiit capacity will beaviiiiable to the orate: volt wish to connect. III order to reSCIAT C;11)aCity YOU MOSI 1),-tv theappropriate capacity charges. Please conuict this office for further Hilormation regarding connection lees kind procedtlres, Should You lmvcon, further questions, pletise feel free to give otir office as call at (772) 567-8000, ext 1834. Sincere I y. 11:0�.e RohAnd Nans Reviewer Indian River Count-, Utilities E,ngtnecring 1801 27h Street Vero Be;ich, It I., 32960 "I'e1:772-567-8000, ext.1636 1ax:772-770-5I43 cc: Ian Kim-% Scnior Planu-, Cit% W'Sebaslian i" 61) Susan Rohani, At(.'['. Chiel'Lonc Ranue PkIl"mm-, (""a omail) \N% Erik Olson, 11,F- Di,cctor of Lhili"y SCIAiccs (via enmil) OndCorrentc, Assistant Director otTifility Services (Vill cmail) Michael C. Hotchkiss, P.E., Cap, Proj, Manager (via email) Utility Project Tile UC11 f4 NjA c. August 20, 2012 Mike Hotchkiss P.E. -- Engineering Department Indian River County Utilities 1840 25" Street Vero Beach, Florida 32960 Project No.: CDJ.14.01.12.DG Subject: Service Availability City of Sebastian in Indian River County, Florida Dear Mike: \cwl PO Box 450006 Kissimmee, Florida 34745 Tel 407 738 1979 Fax 407 348 7552 Our client is planning to construct a 9,100 sq. fl:. retail development on 1 A0 acres. The location of this site is at the northwest corner of intersection of Sebastian Boulevard (CR 512) and Sebastian Crossings Boulevard, Sebastian, Indian River County, Florida 32958. Cadjazz is preparing the construction plans for this project and is requesting a letter of commitmentlavailability from your company, provided that you do in fact provide Water, Sewer, and Waste Disposal services in this area. Please review the attached plans to determine if the proposed construction will conflict with your company's utility lines. We would appreciate any additional information such as any requirements for service connection locations you may have concerning this project. Enclosed is one (1) copy of the site concept plan and location map. Please complete the bottom portion of this letter and return a copy along with any comments that you may have with regard to this project. If you have any questions, or need any additional information, please feel free to call me. Thank you for your cooperation in this matter. Sincerely, Cadjazz Engineering, Wereen, P.E. Copies: I I have been informed of the above -mentioned project and have received a copy of concept plan. I have reviewed the plan and determined: �.---------------•---.....«..»«-_-.....-.............,.........................-"-_-_'•--_------------- ------------------ .........� Our company has iaciGties within the area and does not object to the project. Our company has facilities within the area. We are currently working with the developer to relocate any conflicts. ❑ Oth I o/ 7?2•—13CoAr Signed' Date: Title-------- ---- -------- ----------------Ide------------------------------------------------------------------------ Page l of 1 Project Location Exhibit Sebastian Crossings Blvd ZT LUto clncfi Amherst Ln Jut= Cl-.-.e C ovr:- Carlisle Way PROJECT LOCATION 'OF i sit Fellsmere Rd 95th St Sebastl3tzZ�46 Stony Paint Dr El PROJECT LOCATION Sebastian Crossings • Engineering Consultants - City of Sebastian, Indian River County, Florida P011.4�Mwi&3470 rW=(M713-IM F-SMU&7512 RKM Development OF I MMM SrM DATA, 40 �8�2��n^�`~~~~ W,&tL SALES ^& \- -_ _- __--_-��_-----_'---_--- ~-- _ _' � - ' . ` ---_------ -- --' SUPPORT~ ---- J� _��--' --� --- _-----___- ---_--_ _- __--_-_-----_-��.__---�-_-- Service A vallabi lity ReClUest -PIN 3131822000031000000004M Pat,,e I of I From: Jesse Roland Droland@ircgov-corn] Sent: Friday, August 24, 2012 2:19 PM To: Jan King; Sasan Rohani-I Erik Olson: Cindy Corrente', Mike Hotchkiss Cc: Jesse Roland Subject: Service Availability Request - PIN 31382200003000000004,0 Attachments: Service Availability Request.08-24-12,jrr.pdf 8/27/2012