Loading...
HomeMy WebLinkAboutA - 24-14-ITB - Attachment B - 23162 SEBASTIAN AIRPORT HANGAR MEP S-SREVISION REFERENCE # LIGHT DASHED INDICATES EXISTING FIXTURE OR DEVICE DARK DASHED INDICATES EXISTING FIXTURE OR DEVICE RELOCATED DARK SOLID INDICATES NEW FIXTURE OR DEVICE HATCHED ITEMS INDICATES FIXTURE OR DEVICE TO BE REMOVED OR RELOCATED NOT IN CONTRACT (N.I.C.) ABV - ABBREVIATION AC - AIR CONDITIONER AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE AHU - AIR HANDLING UNIT AP - ACCESS PANEL AS - AIR SEPARATOR BD - BYPASS DAMPER BOP - BOTTOM OF PIPE BHP - BRAKE HORSE POWER BTUH - BRITISH THERMAL UNIT CAP - CAPACITY CD - CONDENSATE DRAIN CFM - CUBIC FEET PER MINUTE CH - CHILLER CHP - CHILLED WATER PUMP CHR - CHILLED WATER RETURN CHS - CHILLED WATER SUPPLY COMB - COMBINATION CONN - CONNECTION CONT - CONTINUE CT - COOLING TOWER CW - COLD WATER CWP - CONDENSER WATER PUMP CWS - CONDENSER WATER SUPPLY CWR - CONDENSER WATER RETURN CU - CONDENSING UNIT DB - DRY BULB DIA - DIAMETER DG - DOOR GRILLE DL - DOOR LOUVER DN - DOWN DP - DIFFERENTIAL PRESSURE DWG - DRAWING EA - EXHAUST AIR EAT - ENTERING AIR TEMPERATURE EDH - ELECTRIC DUCT HEATER EER - ENERGY EFFICIENCY RATIO EF - EXHAUST FAN EFF - EFFICIENCY EG - EXHAUST GRILLE ENT - ENTERING ESP - EXTERNAL STATIC PRESSURE ET - EXPANSION TANK EWT - ENTERING WATER TEMPERATURE EXP - EXPANSION FA - FACE AREA FCU - FAN COIL UNIT FD - FIRE DAMPER FLA - FULL LOAD AMPS FLEX - FLEXIBLE FPM - FEET PER MINUTE FS - FLOOR SINK FT - FEET FV - FACE VELOCITY GA - GAUGE GPM - GALLONS PER MINUTE HP - HORSE POWER HB - HOSE BIBB HR - HOUR HW - HOT WATER HWR - HOT WATER RETURN HWS - HOT WATER SUPPLY HZ - HERTZ IN - INCHES IW - INDIRECT WASTE KEF - KITCHEN EXHAUST FAN KSF - KITCHEN SUPPLY FAN KW - KILOWATT LAT - LEAVING AIR TEMPERATURE LF - LINEAR FOOT LWT - LEAVING WATER TEMPERATURE LD - LINEAR DIFFUSER LIQ - LIQUID LP - LOOP PUMPS MAU - MAKE-UP AIR UNIT MAX - MAXIMUM MBH - THOUSAND BTU PER HOUR MCA - MINIMUM CIRCUIT AMPACITY MECH - MECHANICAL MIN - MINIMUM MD - MOTORIZED DAMPER NC - NORMALLY CLOSED NFPA - NATIONAL FIRE PROTECTION ASSOCIATION NO - NORMALLY OPEN NOM - NOMINAL NTS - NOT TO SCALE OA - OUTSIDE AIR OAU - OUTSIDE AIR UNIT OC - ON CENTER PD - PRESSURE DROP PH - PHASE PRV - PRESSURE REDUCING VALVE PSI - POUNDS PER SQUARE INCH PSIG - PSI GAUGE PTAC - PACKAGED TERMINAL AIR CONDENSER PVC - POLYVINYL CHLORIDE PIPE QTY - QUANTITY RA - RETURN AIR REF - REFRIGERANT RG - RETURN GRILLE RPM - REVOLUTIONS PER MINUTE RLA - RATED LOAD AMPS RTU - ROOF TOP UNIT SA - SUPPLY AIR SEER - SEASONAL ENERGY EFFICIENCY RATING SEN - SENSIBLE SD - SMOKE DAMPER SP - STATIC PRESSURE SWD - SIDEWALL DIFFUSER SWR - SIDEWALL RETURN T - THERMOSTAT TEMP - TEMPERATURE TG - TRANSFER GRILLE TSH - TOTAL SENSIBLE HEAT TSP - TOTAL STATIC PRESSURE TYP - TYPICAL UC - UNDER CUT UG - UNDER GROUND UON - UNLESS OTHERWISE NOTED VAV - VARIABLE AIR VOLUME VLV - VALVE VSD - VARIABLE SPEED DRIVE WB - WET BULB ZD - ZONE DAMPER ∆T - CHANGE IN TEMPERATURE ∆P - CHANGE IN PRESSURE ALL WORK SHALL BE IN COMPLIANCE WITH THE FOLLOWING CODES, BUT NOT LIMITED TO: 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - BUILDING (FBCB) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - EXISTING BUILDING (FBCEB) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - ACCESSIBILITY (FBCA) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - ENERGY CONSERVATION (FBCEC) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - MECHANICAL (FBCM) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - PLUMBING (FBCP) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - FUEL GAS (FBCFG) 8TH EDITION OF THE 2023 FLORIDA FIRE PREVENTION CODE (FFPC) NFPA 70 - 2020 NATIONAL ELECTRICAL CODE (NEC) REVIEW SET David A. DaSilva 54739 CONSULTANTS: DATE PERMIT SET BID SET CONSTRUCTION SET AS BUILT APPROVED: SHEET NO.: CHECKED: DRAWN: DE S C R I P T I O N NO . DA T E REVISIONS Copyright 2024, DDC Engineering, Inc. 24085 MAY 14, 2024 SE B A S T I A N H A N G A R O F F I C E S B U I L D O U T SO U T H & N O R T H B A Y S O F H A N G A R D SE B A S T I A N M U N I C I P A L A I R P O R T SE B A S T I A N , F L O R I D A 3 2 9 5 8 4083 South U.S. Highway 1, Ste. 101 Rockledge, Florida 32955 Phone 321.633.4522 Fax 321.633.4528 www.ddc-engineers.com dasilva.david@ddc-engineers.com C.O.A.: 25988 DDC PROJECT NO.: This item has been electronically signed and sealed by David A. DaSilva, PE #54739. On May 14, 2024, using a Digital Signature. Printed copies of this document are not considered signed and sealed, and all SHA-1 authentication code and signature must be verified on any electronic copies. A.THE CONTRACTOR SHALL VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE BUILDING AND SITE AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSAL SO AS TO BECOME FAMILIAR WITH EXISTING WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OR BY DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. IT IS TO BE UNDERSTOOD THAT UNFORESEEN CONDITIONS PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON THE DRAWINGS. COOPERATION WITH OTHER TRADES IN EQUIPMENT ROUTING AS DETERMINED DURING CONSTRUCTION AND AS DIRECTED BY THE ARCHITECT/ENGINEER MAY BE NECESSARY AND IT IS INTENDED THAT SUCH DEVIATIONS SHALL BE CONSIDERED AS PART OF THIS CONTRACT. IT IS ALSO UNDERSTOOD THAT THE PLANS ARE NOT COMPLETELY TO SCALE. THIS CONTRACTOR IS TO FIELD VERIFY DIMENSIONS OF ALL EXISTING CONDITIONS, PRIOR TO BID AND INCLUDE ANY DEVIATIONS IN THE CONTRACT. B.ALL DEVICES AND EQUIPMENT NOT SHOWN AND IN AREAS OUTSIDE OF REMODELING SHALL REMAIN ACTIVE UNLESS OTHERWISE NOTED. INSTALL AS REQUIRED TO MAINTAIN CONTINUITY TO EXISTING DEVICES AND EQUIPMENT THAT ARE TO REMAIN. C.ALL EQUIPMENT AND MATERIAL REMOVED AND NOT REUSED SHALL BE TURNED OVER TO THE OWNER OR AT THE OWNERS REQUEST LEGALLY DISPOSED OF BY THE CONTRACTOR. D.ALL HVAC DEVICES, EQUIPMENT, DUCTWORK, ETC., THAT ARE REMOVED SHALL BE REMOVED AS DIRECTED BY THE OWNER/ENGINEER, AND CEILING OR WALL SHALL BE PATCHED TO MATCH EXISTING OR NEW FINISH. ALL PATCHES SHALL BE PATCHED OR PAINTED AS DIRECTED BY ARCHITECTURAL DRAWINGS. E.ALL EXISTING HVAC EQUIPMENT, DUCTWORK, DEVICES, ETC., IS NOT SHOWN. IT IS THE CONTRACTORS RESPONSIBILITY TO BECOME FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO BID, AND INCLUDE IN HIS BID THE REMOVAL OF ALL EQUIPMENT, DUCTWORK, DEVICES, ETC., THAT IS NOT BEING REUSED BACK TO ITS SOURCE. F.ALL CONCRETE, WALL PATCHING, CEILING REPAIR, AND OTHER GENERAL WORK REQUIRED FOR INSTALLING THE HVAC SYSTEMS AND TO REPAIR TO "LIKE NEW CONDITION" TO BE PROVIDED AND INSTALLED BY THE CONTRACTOR. G.PROVIDE AND INSTALL ANY ADDITIONAL HANGERS/SUPPORTS REQUIRED TO ACCOMMODATE ANY EQUIPMENT RELOCATIONS. H.COORDINATE ALL CEILING MOUNTED DEVICES WITH ARCHITECTURAL REFLECTED CEILING AND WORK OF ALL OTHER TRACES. I.ITEMS NOTED AS EXISTING TO BE REMOVED SHALL BE REMOVED COMPLETELY. REMOVAL SHALL INCLUDE ALL DEVICES, PIPING, HANGERS, SUPPORTS, ETC. M-1 EED ME C H A N I C A L L E G E N D , N O T E S , & S P E C I F I C A T I O N S JMF DAD MECHANICAL SYMBOLS LEGEND, NOTES, AND SPECIFICATIONS HVAC LEGEND HVAC PIPING LEGEND GENERAL NOTES MECHANICAL SPECIFICATIONS SHEET NOTE CALLOUT ABBREVIATIONS CODE COMPLIANCE REQUIREMENTS GENERAL DEMOLITION NOTES SCOPE OF WORK: CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS AS REQUIRED TO PROVIDE A COMPLETE AND OPERATIONAL HVAC SYSTEM AS INDICATED ON THE DRAWINGS. CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH ALL OTHER TRADES. CHANGES TO THE DESIGN BY THE CONTRACTOR WILL RESULT IN ADDITIONAL DESIGN COST AT CONTRACTORS EXPENSE. SPECIAL PROVISIONS: ALL WORK SHALL BE IN COMPLIANCE WITH THE 2023 FLORIDA BUILDING CODE (8TH EDITION), 2023 FLORIDA BUILDING CODE - MECHANICAL (8TH EDITION), 2023 FLORIDA BUILDING CODE - PLUMBING (8TH EDITION), 2023 FLORIDA FIRE PREVENTION CODE (8TH EDITION), 2023 FLORIDA BUILDING CODE - ENERGY CONSERVATION (8TH EDITION) FOR BUILDING CONSTRUCTION, 2020 NATIONAL ELECTRIC CODE (NEC), UNITED LABORATORIES (UL), AND THE ORDINANCES AND REGULATIONS OF THE LOCAL AUTHORITY HAVING JURISDICTION. SHOP DRAWINGS: BEFORE PURCHASE OR FABRICATION OF EQUIPMENT AND WITHIN 30 DAYS OF AWARD OF GENERAL CONTRACT, CONTRACTOR SHALL SUBMIT TO THE ARCHITECT/ENGINEER FOR APPROVAL, 3 COPIES OF SHOP DRAWINGS FOR ALL DUCTWORK AND HVAC EQUIPMENT AND MATERIALS. SHOP DRAWINGS SHALL INDICATE WORKING AND ERECTION DIMENSIONS, ELECTRICAL CHARACTERISTICS (VOLTS, PHASE AND AMPS), LOCATION AT WHICH MATERIALS AND EQUIPMENT ARE TO BE INSTALLED AND OTHER ESSENTIAL DATA. PARTIAL OR INCOMPLETE SUBMITTALS WILL NOT BE ACCEPTED. ANY MATERIAL USED WITHOUT APPROVAL WILL BE REJECTED. PROVIDE SUBMITTALS ON ALL ITEMS EXCEPT PIPING. SUBMIT SHOP DRAWINGS TO ELECTRICAL CONTRACTOR FOR APPROVAL AND COORDINATION. A COMPLETE HVAC DUCT LAYOUT INCLUDING AIR DISTRIBUTION DEVICES SHALL BE SUBMITTED TO ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION. MATERIALS: MATERIALS, UNLESS OTHERWISE NOTED, SHALL BE NEW, FREE OF DEFECTS AND IN ACCORD WITH FOLLOWING SCHEDULES AND PARAGRAPHS. THE APPROVAL OF ANY MATERIALS WILL NOT BE CONSIDERED AS ACCEPTANCE OF WORK WHERE INSTALLED IF SUCH MATERIALS PROVE DEFECTIVE. WHERE NO SPECIFIC WEIGHTS OR GRADES ARE SPECIFIED, MATERIALS SHALL BE OF THE GENERALLY ACCEPTED STANDARD WEIGHT AND GRADE. DUCTWORK (FIBERGLASS): THE HEATING AND AIR CONDITIONING DUCTWORK SHALL BE OWENS CORNING TYPE 475-FR, 1-1/2" THICK FIBERGLASS DUCT (MIN R-VALUE OF 6) OR APPROVED EQUAL. THE DUCT SYSTEM, INCLUDING BOARD, VAPOR BARRIER, TAPES AND ADHESIVES, SHALL BE UL LISTED AND LABELED CLASS 1 AIR DUCT. DUCT SHALL BE INSTALLED PER THE STANDARD OF SMACNA-10 IN CHAPTER 15 OF FBCM. EXHAUST DUCT SHALL BE GALVANIZED. DUCTWORK (GALVANIZED STEEL): THE HEATING AND AIR CONDITIONING DUCTWORK SHALL BE G-90 GALVANIZED STEEL PAINTED, w/ BLANKET INSULATION (MIN. R-6). EXHAUST DUCT SHALL BE GALVANIZED. PROVIDE FLEX DUCT TO AIR DEVICE WHERE SHOWN (NO MORE THAN 6'-0" LONG). ALL DUCTWORK PENETRATING FIRE-RATED WALLS SHALL HAVE A FIRE DAMPER. THE USE OF R-6 DUCTBOARD MAY BE USED AS AN ALTERNATE (OWNER OPTION). AIR DISTRIBUTION OUTLETS: GRILLES, REGISTERS, AND DIFFUSERS SHALL REQUIRE ADC, ARI, AND AMCA COMPLIANCE. BORDER STYLES AND FINISHES SHALL BE COMPATIBLE WITH ADJACENT CEILING SYSTEMS, AND CONSTRUCTED OF MATERIALS AND COMPONENTS AS REQUIRED FOR A COMPLETE INSTALLATION. SUPPLIER/MANUFACTURER SHALL VERIFY EACH DEVICE FOR A MAXIMUM NECK VELOCITY OF 500 FPM AND NC-30. REFRIGERATION: REFRIGERANT PIPING SHALL BE ACR COPPER TUBING, WITH WROUGHT COPPER FITTINGS IN CONFORMANCE WITH ASTM B280. A.JOINTS IN COPPER TUBE (REFRIGERANT SERVICE) - CUT SQUARE, BURR, CLEAN FITTING AND TUBE TO CUP DEPTH OF FITTING APPLY THIN FILM OF BRAZING FLUX TO TUBE END AND FITTING. USE SILVER SOLDER AND OXYGEN-ACETYLENE EQUIPMENT ONLY IN MAKING JOINTS. PURGE WITH NITROGEN WHEN HEATING. B.PIPING SHALL BE SIZED AND INSTALL PER THE HEAT PUMP EQUIPMENT MANUFACTURER'S WRITTEN INSTRUCTION. C.SUCTION LINES SHALL BE INSULATED CONTINUOUSLY WITH EXTERIOR EXPOSED SURFACES TREATED PER MANUFACTURER'S RECOMMENDATIONS. INSULATION SHALL BE ARMAFLEX OR EQUAL. D.REFRIGERANT PIPING EXPOSED TO EXTERIOR SHALL BE INSULATED AND WRAPPED WITH ALUMINUM JACKET WITH A MINIMUM 2" OVERLAPS. JACKET SHALL BE SECURED USING BANDS AND SEALS. CONDENSATE DRAIN LINE: CONDENSATE DRAIN LINES SHALL BE PROVIDED FOR AIR HANDLING UNITS. DRAIN LINES SHALL BE SCHEDULE 40 PVC. A.DRAIN LINES SHALL BE GRADED IN THE DIRECTION OF FLOW WITH A SLOPE OF 1 4" PER FOOT. B.WATER SEALS SHALL BE PROVIDED IN THE CONDENSATE DRAIN FROM UNIT. THE DEPTH OF SEAL SHALL BE EQUAL TO THE TOTAL STATIC PRESSURE RATING OF THE UNIT TO WHICH THE SEAL IS CONNECTED. WATER SEALS SHALL BE CONSTRUCTED TO TWO TEES AND AN APPROPRIATE U-BED WITH THE OPEN END TO EACH TEE PLUGGED, HANDTIGHT. C.ROUTE DRAIN LINE INTO OUTSIDE FRENCH DRAIN OR SPLASH BLOCK. TEST AND BALANCE PROVIDE A COMPLETE TEST AND BALANCE REPORT AND SUBMIT TO ENGINEER FOR REVIEW. T&B FIRM MUST BE NEBB OR AABC CERTIFIED. READINGS SHALL INCLUDE BUT SHALL NOT BE LIMITED TO THE FOLLOWING: ·SUPPLY AIR CFM ·RETURN AIR CFM ·STATIC PRESSURE ·EXHAUST AIR CFM *ANY CHANGES TO THESE DOCUMENTS BASED ON CONTRACTOR REQUESTED REVISIONS SHALL BE CONSIDERED ADDITIONAL SERVICES. # 1.VERIFY THAT ALL EQUIPMENT, AS SHOWN ON THESE DRAWINGS, WILL NOT CONFLICT WITH ANY DRAINS, SCUTTLES, JOINTS, VENTS, PIPING OR OTHER EQUIPMENT PRIOR TO INSTALLATION. 2.EQUIPMENT SUPPLIER SHALL PROVIDE COMPLETE INFORMATION AND COOPERATE WITH THE OWNER'S REPRESENTATIVE AS REQUIRED FOR PROJECT COMPLETION AND COORDINATION. 3.CONTRACTOR SHALL ADMINISTER AND SUBMIT ALL DRAWINGS FOR PERMITTING. 4.ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 10'-0" FROM ANY EXHAUST FAN, GAS OR PLUMBING VENT. 5.PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE CONNECTIONS TO ALL MOVING MACHINERY. 6.ALL PIPE AND DUCTWORK DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 7.COORDINATE WITH ALL OTHER TRADES, ALL REQUIRED OPENINGS AND ROOF PENETRATIONS. ALL REQUIRED OPENINGS IN FOUNDATIONS, FLOORS, WALLS AND ROOF SHALL BE MADE AND INSTALLED INTO THE STRUCTURE WITH THE USE OF SLEEVES, CURBS, ETC. 8.PROVIDE SHOP DRAWINGS FOR ALL HVAC EQUIPMENT AND MATERIALS. 9.CONTROL PANELS AND REMOTE SENSORS SHALL BE LOCATED GENERALLY AS SHOWN. EXACT LOCATIONS SHALL BE FIELD COORDINATED TO AVOID INTERFERENCE WITH WALL MOUNTED WORK. 10.FURNISH AND INSTALL 4" HIGH BLACK NAMEPLATES FOR ALL EQUIPMENT. 11.FIELD VERIFY ALL EXISTING SERVICES PRIOR TO START OF CONSTRUCTION. 12.REMOVE EXISTING CEILINGS, GRID, CEILING DEVICES, ETC., TO INSTALL NEW HVAC SYSTEMS. REINSTALL OR PROVIDE NEW CEILING GRID AND TILE, TO MATCH EXISTING CONDITIONS. REINSTALL EXISTING CEILING DEVICES. 13.CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF EXISTING CEILING, WALLS, SLABS, ETC. TO INSTALL NEW SYSTEM. MINIMIZE SAW CUTTING OF WALLS, SLABS, ETC. PATCH AND REPAIR ALL SURFACES IMPACTED BY CONSTRUCTION. PAINT ALL SURFACE TO MATCH EXISTING FINISH. DESIGN CRITERIA DESIGN TEMPERATURES: OUTDOOR AIR: SUMMER:95°F DB/80°F WB WINTER:30°F DB INSIDE AIR: SUMMER:75°F DB/60% RH WINTER:72°F DB NOTES: THE DESIGN CRITERIA ABOVE IS BASED ON ASHRAE STANDARD 62.1. ANY CHANGES TO THIS OCCUPANCY OR FLOOR PLAN WILL REQUIRE FURTHER REVIEW AND MODIFICATIONS TO THIS VENTILATION SYSTEM. POINT OF CONNECTION POINT OF DISCONNECT MISCELLANEOUS (150) EXISTING DIFFUSER WITH CFM'S CONTROL VALVE CONDENSER WATER SUPPLY CONDENSER WATER RETURN CONDENSATE CONNECTION, BOTTOM CONNECTION, TOP CWS CWR CHECK VALVE STRAINER BUTTERFLY VALVE CALIBRATING BALANCING VALVE GATE VALVE OR BALL VALVE UNION CD THERMOMETER FLOW DIRECTION CHR CHILLED WATER RETURN CHILLED WATER SUPPLYCHS HOT WATER SUPPLYHWS NEW CFM EXISTING CFM REFRIGERANT PIPINGREF SWR SWD 20"Ø T ROUND SPIRAL MANUAL BALANCING DAMPER FIRE & SMOKE DAMPER (WITH ACCESS PANEL) FIRE DAMPER (WITH ACCESS PANEL) 90° ELBOW W/TURNING VANES ROUND DIFFUSER SIDE WALL RETURN SIDE WALL DIFFUSER CEILING DIFFUSER, ROUND NECK (CEILING DIFFUSERS ARE 4-WAY THROW UON) TEMPERATURE SENSOR MOTORIZED CONTROL DAMPER THERMOSTAT/TEMPERATURE SENSOR PRESSURE SENSOR BACKDRAFT DAMPER CEILING MOUNTED ACCESS DOOR RADIUS ELBOW W/O TURNING VANES OUTSIDE AIR LOUVER OUTSIDE AIR ROOF INTAKE ELECTRIC DUCT HEATER ITEM(S) TO BE REMOVED DOUBLE LINE DUCTWORK, FIRST DIMENSION IS SIDE SHOWN.20x12 FLEX DUCTWORK VARIABLE AIR VOLUME (VAV) BOX W/ HEAT BD P TS M SINGLE LINE DUCTWORK, FIRST DIMENSION IS SIDE SHOWN. 20x12 EDH-# OAL RI-# DUCT UP TO OUTSIDE AIR ROOF INTAKE ABOVERI-# EXHAUST AIR ROOF VENTRV-# DUCT UP TO EXHAUST AIR ROOF VENT ABOVERV-# ROOF TOP EXHAUST FANEF-# DUCT UP TO ROOF TOP EXHAUST FAN ABOVEEF-# CEILING RETURN GRILLE WITH SQUARE CONNECTION CEILING RETURN GRILLE WITH ROUND CONNECTION CEILING EXHAUST GRILLE EXHAUST FANEF-# H HUMIDISTAT/HUMIDITY SENSOR R S PHOTOELECTRIC DUCT SMOKE DETECTOR R=RETURN S=SUPPLY SMOKE DAMPER (WITH ACCESS PANEL) 20"Ø DOUBLE LINE ROUND DUCTSOCK 20"Ø SINGLE LINE ROUND DUCTSOCK VARIABLE AIR VOLUME (VAV) BOX W/ NO HEAT ZONE DAMPER IN-LINE EXHAUST FAN CONDENSER UNIT AC-# VERTICAL AC UNIT HORIZONTAL AC UNIT HORIZONTAL HEAT PUMP UNIT PACKAGED ROOFTOP OR GROUND MOUNTED AC UNIT EQUIPMENT TAG SEQUENCE OF OPERATION PROVIDE INDIVIDUAL ROOM LED PROGRAMMABLE THERMOSTATS THAT SHALL MAINTAIN ROOM SET POINTS. 1.AIR HANDLER FAN SHALL START AND STOP ON COMMAND FROM THERMOSTAT BASED ON TIME OF DAY SCHEDULE. 2.LOCAL OVERRIDE CONTROL WILL START FAN AND PERMIT IT TO RUN FOR A PREDETERMINED INTERVAL. 3.OUTSIDE AIR DAMPER SHALL OPEN AND SHALL BE CONTROLLED BY A MOTORIZED DAMPER INTERLOCKED WITH THE COMPRESSOR. 4.ON A RISE OF RETURN OR SPACE AIR TEMPERATURE FROM 75°F SETPOINT (ADJUSTABLE), THE CONTROLLER SHALL ENERGIZE THE UNIT'S COMPRESSOR TO MAINTAIN 57°F SUPPLY LEAVING AIR TEMPERATURE SETPOINTS. 5.SPACE AIR TEMPERATURE SETPOINT SHALL BE SET BY THE OWNER AND SHALL BE ADJUSTABLE. 6.THE CONTROLLER SHALL STAGE ONE COMPRESSOR AT A TIME. IF TEMPERATURE INCREASES, THE SECOND COMPRESSOR WILL BE STAGED ON (IF DUAL COMPRESSOR IS FURNISHED) 7.IN THE WINTER MONTHS, THE UNIT'S HEATERS SHALL BE STAGED ON TO MAINTAIN 68°F. 8.IF HUMIDITY INCREASES ABOVE 60%. THE UNITS SHALL ENERGIZE THE COMPRESSOR TO MAINTAIN A COLD COIL. ZD-# VAV-# VAV-# EF-# CU-# AC-# AC-# HP-# RTU-# DUCTWORK/SUPPORTS ELECTRIC DISCONNECTS CONTROLS PIPING INSULATION EXHAUST FANS DIFFUSERS/GRILLES ALL HVAC EQUIPMENT ITEM COPY FOR OWNER PRODUCT DATA SHOP DRAWINGS TEST REPORTS COORDINATION DRAWINGS WIRING DIAGRAMS O & M MANUAL SHOP DRAWING SUBMITTALS 1 2 3 4 1 2 1 2 1 2 1 2 1 2 NOTES: 1- FOR REVIEW 2- FOR RECORD 3- COLOR SELECTION 4- SAMPLE NOTE: FOR ALL MATERIALS FOR CONSTRUCTION, INSTALLATION REQUIREMENTS AND TESTING REQUIREMENTS, REFER TO CONTRACT SPECIFICATIONS. CONTRACTOR SHALL SUBMIT ALL ITEMS UNDER ONE SUBMITTAL THAT REFERENCES DDC PROJECT NUMBER. NO PARTIAL SUBMITTALS WILL BE ACCEPTED. ALL SUBMITTALS SHALL BE EMAILED TO INFO@DDC-ENGINEERS.COM . REVIEW 2 A A A.8 A.8 B.8 A.8 3 4 5 6 MGMT. OFFICE #1 107 MGMT. OFFICE #2 108 CONF. RM. 109 RECEPT. AREA 110 TRAINING #1 112 CORR. 111 TRAINING #2 113 TRAINING #3 114 TRAINING #4 115 FOYER 117 CORR. 118 UTIL. RM. 119 R.R. 120 R.R. 121 PILOT BRIEFING RM. 123 CORR. 122 RECEPT. OFFICE 116 225 225 325 125 125 100 125 100 150 650 200 12 " x 1 2 " 14 " x 1 2 " 12 " x 1 2 " 14 " x 1 2 " AC-1N AC-2N 22"x12" 22"x12" 18 " x 1 2 " 14 " x 1 2 " 12 " x 1 2 " 12 " x 1 2 " 14 " x 1 2 " 18 " x 1 2 " EX. EFEX. EF CU-1N CU-2N 22 " x 1 2 " 22 " x 1 2 " T AC-2N TYP.3 TYP.2 EX. EF 125 125 125 700 350 350 50 100 150 T AC-1N 8"Ø M M 3 4 4 6 5 7 7 7 TYP. 10 8 50 75 TYP. TYP. 125 11 D D C B A A 10 9 C.2A.9 SIMULATOR AREA 100 OFFICE #1 101 OFFICE #2 102 BREAKROOM 103 UTILITY ROOM 104 R.R. 105 R.R. 106 12"x10" SWD 300 TYP. CFM 300 CFM 300 CFM 300 CFM 12"x12"20"x12" 225 200 EX. EF EX AC-1S 50 50EX CU-1S 75 REVIEW SET David A. DaSilva 54739 CONSULTANTS: DATE PERMIT SET BID SET CONSTRUCTION SET AS BUILT APPROVED: SHEET NO.: CHECKED: DRAWN: DE S C R I P T I O N NO . DA T E REVISIONS Copyright 2024, DDC Engineering, Inc. 24085 MAY 14, 2024 SE B A S T I A N H A N G A R O F F I C E S B U I L D O U T SO U T H & N O R T H B A Y S O F H A N G A R D SE B A S T I A N M U N I C I P A L A I R P O R T SE B A S T I A N , F L O R I D A 3 2 9 5 8 4083 South U.S. Highway 1, Ste. 101 Rockledge, Florida 32955 Phone 321.633.4522 Fax 321.633.4528 www.ddc-engineers.com dasilva.david@ddc-engineers.com C.O.A.: 25988 DDC PROJECT NO.: This item has been electronically signed and sealed by David A. DaSilva, PE #54739. On May 14, 2024, using a Digital Signature. Printed copies of this document are not considered signed and sealed, and all SHA-1 authentication code and signature must be verified on any electronic copies. M-2 EED/SBH ME C H A N I C A L P L A N JMF DAD #PLAN NOTES 1.SIZE FLEX DUCT BASED ON SCHEDULE PROVIDED. 2.INSULATE BACK OF ALL DIFFUSERS. 3.MOUNT THERMOSTAT AT 48" ABOVE FINISHED FLOOR. 4.SUSPEND AC UNIT FROM STRUCTURE. SEE DETAIL. 5.PROVIDE O.A. WALL CAP. 6.PROVIDE MOTORIZED AND MANUAL DAMPER IN O.A. DUCT. 7.ROUTE REFRIGERANT PIPING OVERHEAD TO CONDENSER UNIT. 8.ROUTE 3 4" CONDENSATE DRAIN TO EXTERIOR GREEN AREA OR DRYWELL. 9.MOUNT CONDENSER UNIT ON 4" PAD AND ANCHOR TO PAD. 10.ROUTE REFRIGERANT PIPE DOWN WALL. PROVIDE 18 GAUGE PAINTED SHEET METAL ENCLOSURE. SEAL ALL OPENINGS IN ENCLOSURE. NORTH BAY 3/16" = 1'-0" MECHANICAL PLAN SOUTH BAY 3/16" = 1'-0" MECHANICAL PLAN NOTE: 1.RETURN AIR CFMS FOR GRILLES SHALL MATCH SUPPLY AIR CFMS FOR THAT ROOM. REVIEW SET David A. DaSilva 54739 CONSULTANTS: DATE PERMIT SET BID SET CONSTRUCTION SET AS BUILT APPROVED: SHEET NO.: CHECKED: DRAWN: DE S C R I P T I O N NO . DA T E REVISIONS Copyright 2024, DDC Engineering, Inc. 24085 MAY 14, 2024 SE B A S T I A N H A N G A R O F F I C E S B U I L D O U T SO U T H & N O R T H B A Y S O F H A N G A R D SE B A S T I A N M U N I C I P A L A I R P O R T SE B A S T I A N , F L O R I D A 3 2 9 5 8 4083 South U.S. Highway 1, Ste. 101 Rockledge, Florida 32955 Phone 321.633.4522 Fax 321.633.4528 www.ddc-engineers.com dasilva.david@ddc-engineers.com C.O.A.: 25988 DDC PROJECT NO.: This item has been electronically signed and sealed by David A. DaSilva, PE #54739. On May 14, 2024, using a Digital Signature. Printed copies of this document are not considered signed and sealed, and all SHA-1 authentication code and signature must be verified on any electronic copies. M-3 EED/SBH ME C H A N I C A L S C H E D U L E S A N D D E T A I L S JMF DAD AIR BALANCE NORTH BAY OUTSIDE AIR AC-1N = 150 CFM AC-2N = 150 CFM TOTAL OUTSIDE AIR = 300 CFM EXHAUST AIR EX. EF(3)= 225 CFM TOTAL EXHAUST AIR = 225 CFM BUILDING IS POSITIVE = 75 CFM AC SPLIT SYSTEM SCHEDULE ESPCFM NOMINAL MANUFACTURER NOTES:1.PROVIDE MOTORIZED OUTSIDE AIR INTAKE DAMPER FOR THE OA DUCT. 2.INSTALL AND ANCHOR CONDENSER UNIT TO STRUCTURE ( SLAB). 3.MIN. SEER OF 16.0 MARK OUTDOOR INDOOR/O.A. CFM COOLING CAPACITY AMB. TEMP TOT MBH SENS MBH ENT DB WB ENT ELECTRICAL DATA (OUTDOOR UNIT) NO COMP COMP RLA(EA)FAN NO FLA(EA) FAN HP FAN PHASE VOLT/ ELECTRICAL DATA (INDOOR UNIT) FAN HP KW HEAT STAGE VOLT/ PHASE TONS NOMINAL 4.COORDINATE INSTALLATION OF SMOKE DETECTORS WITH DIV. 16 (NOT REQ'D IF 2000 CFM OR LESS. 5.PROVIDE VIBRATION ISOLATIONS. 6.PROVIDE 410A REFRIGERANT. 7.PROVIDE SINGLE POINT ELECTRICAL CONNECTION WITH DISCONNECT. 8.PROVIDE 1" PLEATED FILTERS. 9.PROVIDE 5 YEAR WARRANTY. 10.PROVIDE CONDENSER COIL GUARDS. 11.PROVIDE PROGRAMMABLE THERMOSTAT. 12.BALANCE UNITS BASED ON AIRFLOW RATES SHOWN ON DRAWINGS. 13.PROVIDE VARIABLE SPEED AIRHANDLER WITH HUMIDISTAT CONTROL. 14.PROVIDE UNLOADING COMPRESSOR. (MIN. 2 STAGES) 15.PROVIDE 30" WIDE AND 30" DEEP CLEAR SPACE ON SERVICE SIDE OF EQUIPMENT. MCA/ MOCP MCA/ MOCP EXHAUST FAN SCHEDULE MOTORMARKTYPECFMESPWATTSRPM HP DRIVE TYPE FAN SERVICE SONES MAX PHASE VOLT /CONTROL MANUFACTURER / MODEL NOTES PROVIDE THE FOLLOWING: DISCONNECT SWITCH, VIBRATION ISOLATORS, BACKDRAFT DAMPER, SPEED CONTROL EX. EF CEILING 70 0.25 20 --DIRECT RESTROOMS 5 115/1 SWITCH EXISTING SEE BELOW N.T.S. TYPICAL DUCT / DIFFUSER DETAIL AIR FLOW DUCT SUPPORT DAMPER OPERATOR SHALL BE ACCESSIBLE. PROVIDE EXTENSION THRU INSULATION PROVIDE SADDLE SUPPORT SUPPORT FROM STRUCTURE INSULATED FLEX DUCT SPIN-IN FITTING WITH SCOOP AND VOLUME DAMPER DUCT CLAMP SUPPORT FROM STRUCTURE SUPPLY AIR DUCT DIFFUSER CEILING INSULATE BACK OF ALL AIR DISTRIBUTION DEVICES M3 N.T.S. CONDENSER UNIT DETAIL WALL MOUNTED DISCONNECT, NEMA 3R UNIT ANCHORS NOTES: 1.CONDENSERS LOCATED NEAR COASTAL WATERS SHALL BE COATED WITH BRONZEGLOW OR HERESITE COIL COATING. 2.UNIT ANCHORS SHALL BE FLORIDA AND MIAMI/DADE PRODUCT APPROVED AS MANUFACTURED BY MIAMI TECH, INC. (FL# FL19731-R-3) OR EQUAL. INSTALL AS REQUIRED BY MANUFACTURER TO WITHSTAND WIND LOADS OF 175 MPH. USE CARE AND DO NOT PUNCTURE COMPONENTS. FIBER MESH CONCRETE AT 3000 PSI. 4" HIGH, MEASURED FROM HIGHEST POINT OF GRADE. EXTERIOR GRADE 20 GAUGE SHEET METAL ENCLOSURE. PAINT TO MATCH EXTERIOR. SEAL OPENINGS. REFRIGERANT PIPING. MOUNT ON WALL ON UNISTRUT SUPPORT. SCREEN M1 N.T.S. INSULATED PIPE HANGER DETAIL M-D009 SIZES UP TO 3" SINGLE MULTIPLE PIPE PIPE SADDLE (TYP.) ALL INSULATION PASSES THRU HANGER UNBROKEN LOCKNUT (TYP.) UNISTRUT OR ANGLE IRON WASHER (TYP.) PIPE SADDLE (18 GA., 18" LONG) ATTACH TO STRUCTURE CONTINUOUS THREADED ROD U-BOLT PIPE INSULATION PIPE M2 ~ 5" DRAINABLE SECURE TO WALL LINTEL DUCT BIRDSCREEN LOUVER (MIN.) LOUVER FRAME EXISTING WALL CAULK ALL AROUND CAULK RAIN SILL N.T.S. LOUVER DETAIL TYPICAL WALLM4 N.T.S. CONDENSATE DRAIN P-TRAP DETAIL NOTE: 1.FILL TRAP MANUALLY ON INITIAL START-UP. 2.PIPE SIZE SHALL NOT BE LESS THAN DRAIN PAN CONNECTION SIZE. 3.A = 11 2 TIMES FAN SUCTION S.P. B = 12" PLUS FAN DISCHARGE S.P. 4.ALL CONDENSATE PIPING TO BE COPPER. 5.INSULATE ALL DRAIN LINES WITH 3 4" ARMAFLEX B A SLOPE TO DRAIN DRAIN PAN CASING SLEEVE AIR HANDLER UNIT UNION THREADED CAP WITH 1 2"Ø HOLE DRILLED IN TOP, HAND TIGHTENED. THREADED CAP, HAND TIGHTENED 12" EXTENSION PIPE WITH THREADED CAP AT END FLOAT SWITCH IN SECONDARY DRAIN LINE TO DISABLE AHU SHOULD SECONDARY DRAIN LINE ACCUMULATE WATER. M5 AIR DISTRIBUTION DEVICE SCHEDULE MANUFACTURER / MODEL REMARKS:1.PROVIDE OPPOSED BLADE VOLUME DAMPERS. 2.CONTRACTOR SHALL COORDINATE GRILLES, DIFFUSERS AND REGISTER'S BORDER TYPES WITH CEILING, WALLS, EQUIPMENT ETC. 3.PROVIDE ALL ALUMINUM CONSTRUCTION. MARK NC MAX SIZE (IN.) NECK FLEX DIAM. (IN.)REMARKSTYPECFM RANGE 25 6 825 1025 1225 1425 24x24 12x12 0-800 25 20x20 - -48x2425801-3000 SWD SWR 401-750 0-400 -12x1225 -18x1825DG DIFFUSERS SUPPLY RETURN GRILLE SIDEWALL DIFFUSER SIDEWALL RETURN DOOR GRILLE 3 1,2,3 1,2,3 1,2,3 1,2,3 1.ALL GRILLES SHALL BE FULL FACE OF MODULE. ALL LAY-IN CEILING RETURN MODULES SHALL BE 24"x24" WITH 20"x20"x1" FILTER 2.INSULATE THE BACK OF ALL SUPPLY AND RETURN AIR DEVICES. 3.PROVIDE BORDER TYPE 1 FOR LAY-IN CEILINGS, AND BORDER TYPE 3 FOR GYPSUM BOARD CEILINGS. 4.PROVIDE 1" PLEATED FILTER. 5.THE NUMBER ADJACENT TO THE FIXTURE INDICATES AIR FLOW (CFM). NOTES: -25 -DWGS SEE DWGS -25-SEE 0-100 101-200 201-300 301-400 401-600 6"Ø 8"Ø 10"Ø 12"Ø 14"Ø 1001-1500 25 1818"Ø 601-1000 162516"Ø GREENHECK XG-5500-APD GREENHECK XG-RH GREENHECK XG-H4004 GREENHECK XG-RH GREENHECK XG-DGDF PROVIDE LOUVERS AS MANUFACTURED BY GREENHECK MODEL EVH-501D. LOUVER SHALL BE 5" DRAINABLE ALL ALUMINUM. PAINT TO MATCH EXISTING FINISH. ALL LOUVERS TO MEET CURRENT MIAMI-DADE HURRICANE STANDARDS AND FLORIDA BUILDING CODE. SIZE LOUVER AS SHOWN BELOW (IF NOT SPECIFIED ON DRAWINGS). CFM LOUVER SIZE 0-300 501-1000 1001-1500 1501-2000 24"X16" 36"X16" 48"X16" NOTE: PROVIDE REMOVABLE INSECT SCREEN ON BACK OF LOUVER. 72"X16" LOUVER SCHEDULE 301-500 24"X16" SCHEDULE CFM DUCT SIZE 0-100 6"Ø 8"Ø101-200 10"Ø201-300 12"Ø301-400 14"Ø401-600 18"Ø1001-1500 20"Ø1501-2000 SIZE BOTH SUPPLY AND RETURN BASED UPON AIRFLOWS ABOVE. 16"Ø601-1000 TRANSFER DUCT SIZE 9"Ø 12"Ø 16"Ø 18"Ø 22"Ø 28"Ø 30"Ø 24"Ø FLEX DUCT SD FLOAT SWITCH BEYOND AHU EXTEND 4" COIL SECTION SECTION FILTER CONNECTION (TYP) FLEXIBLE DUCT AIR DUCT OUTSIDE DAMPER RETURN AIR W/ AIR SUPPLY DRAIN PAN W/ DAMPER N.T.S. HORIZONTAL AIR HANDLING UNIT P-TRAP PROVIDE NEOPRENE PAD PRESSURE TREATED BLOCK BETWEEN BLOCK AND UNIT M6 EX. AC-1S/CU-1S 1800 175 .5 95 80 67 41.9 58.0 1 28.8 1 1.9 1/4 208/1 32/50 3/4 9.0 1 208/1 54/60 5 TRANE/CARRIER/LENNOX (PEOPLE/1000 SQ.FT.) OCCUPANCY DENSITY OUTDOOR AIR SCHEDULE UNIT TAG PERSON CFM/ FBC-MECHANICAL TABLE 403.3.1.1 (SQ. FT) AREA (# OF PEOPLE) ZONE MAX OCCUPANCY AREA CFM/ EX. AC-1S OFFICE 5 5 0.06190110 164 USE ZONE PROVIDED OA CFMPER SEC. OA CFM 403.2 *O.A. CFM REQUIRED TOTAL 175 AC-1N/2N OFFICE 5 5 0.06287215 247 300 AC-1N/CU-1N 1600 150 .5 95 80 67 35.9 49.5 1 19.8 1 1.4 1/6 208/1 26/40 1/2 9.0 1 208/1 54/60 4 TRANE/CARRIER/LENNOX AIR BALANCE SOUTH BAY OUTSIDE AIR AC-1S = 175 CFM TOTAL OUTSIDE AIR = 175 CFM EXHAUST AIR EX. EF(2)= 150 CFM TOTAL EXHAUST AIR = 150 CFM BUILDING IS POSITIVE = 25 CFM COOLING/HEATING LOAD SUMMARY OUTDOOR INDOOR COOLING (MBH) ZO N E U N I T # AR E A S Q U A R E F E E T TO T A L H E A T I N G WI T H O U T I S D E A I R (M B H ) GR A I N S W A T E R (D I F E R E N C E ) DR Y B U L B ( D B ) WE T B U L B ( W B ) DR Y B U L B ( D B ) RE L A T I V E HU M I D I T Y ( % R H ) TO T A L S E N S I B L E TO T A L L A T E N T TO T A L W I T H OU T S I D E A I R AC-1N 1600 95 80 75 60 35.9 13.6 49.5 31 14.2 EX. AC-1S 1800 95 80 75 60 41.9 16.1 58 30 16.2 NOTES: -THIS SUMMARY IS BEING SUBMITTED IN ACCORDANCE WITH 2023 FLORIDA BUILDING CODE (8TH EDITION), 2023 ENERGY CONSERVATION CODE (8TH EDITION), SECTION C403.2.1. -SIZING METHOD USED: ASHRAE TRANSFER FUNCTION METHOD. AC-2N/CU-2N 1600 150 .5 95 80 67 35.9 49.5 1 19.8 1 1.4 1/6 208/1 26/40 1/2 9.0 1 208/1 54/60 4 TRANE/CARRIER/LENNOX AC-2N 1600 95 80 75 60 35.9 13.6 49.5 31 14.2 REVISION REFERENCE # LIGHT DASHED INDICATES EXISTING FIXTURE OR DEVICE DARK DASHED INDICATES EXISTING FIXTURE OR DEVICE RELOCATED DARK SOLID INDICATES NEW FIXTURE OR DEVICE HATCHED ITEMS INDICATES FIXTURE OR DEVICE TO BE REMOVED OR RELOCATED NOT IN CONTRACT (N.I.C.) ABV - ABBREVIATION AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE AW - ACID WASTE AWS - ACID WASTE STACK AVS - ACID VENT STACK BOP - BOTTOM OF PIPE BHP - BRAKE HORSE POWER BTH - BRITISH THERMAL UNIT CAP - CAPACITY CD - CONDENSATE DRAIN COMB - COMBINATION CONN - CONNECTION CONT - CONTINUE CW - COLD WATER DIA - DIAMETER DN - DOWN DWG - DRAWING ECO - EXTERIOR CLEAN OUT EFF - EFFICIENCY ENT - ENTERING EWC - ELECTRIC WATER COOLER EWS - EMERGENCY EYEWASH/SHOWER EWT - ENTERING WATER TEMPERATURE EXP - EXPANSION F - FAHRENHEIT FA - FIRE ALARM FL - FLOOR FLA - FULL LOAD AMPS FLO - FLOOR CLEAN OUT FD - FLOOR DRAIN FS - FLOOR SINK FT - FEET GA - GAUGE GAL - GALLON GALV - GALVANIZED GPM - GALLONS PER MINUTE GW - GREASE WASTE GWH - GAS WATER HEATER HB - HOSE BIBB HP - HORSE POWER HR - HOUR HW - HOT WATER HWR - HOT WATER RETURN HWS - HOT WATER SUPPLY IE - INVERT ELEVATION IN - INCHES IW - INDIRECT WASTE KW - KILOWATT LF - LINEAR FOOT LWT - LEAVING WATER TEMPERATURE LIQ - LIQUID LP - LIQUID PROPANE MAX - MAXIMUM MBH - THOUSAND BTU PER HOUR MCA - MINIMUM CIRCUIT AMPACITY MECH - MECHANICAL MEZZ - MEZZANINE MIN - MINIMUM MTD - MOUNTED NC - NORMALLY CLOSED NFPA - NATIONAL FIRE PROTECTION ASSOCIATION NO - NORMALLY OPEN NOM - NOMINAL NTS - NOT TO SCALE OC - ON CENTER OW - OILY WASTE PH - PHASE POC - POINT OF CONNECTION PRESS - PRESSURE PRV - PRESSURE REDUCING VALVE PSI - POUNDS PER SQUARE INCH PSIG - PSI GAUGE PVC - POLYVINYL CHLORIDE PIPE QTY - QUANTITY RAD - REFRIGERANT AIR DRYER RD - ROOF DRAIN REF - REFRIGERANT RL - RAIN LEADER RPM - REVOLUTIONS PER MINUTE RLA - RATED LOAD AMPS SH - SHOWER SOV - SHUT OFF VALVE SP - STATIC PRESSURE SRD - SECONDARY ROOF DRAIN SS - SANITARY SEWER OR STAINLESS STEEL ST - STORM DRAIN TEMP - TEMPERATURE TP - TRAP PRIMER TYP - TYPICAL UG - UNDER GROUND UON - UNLESS OTHERWISE NOTED V - VENT VEL - VELOCITY VLV - VALVE VSD - VARIABLE SPEED DRIVE VTR - VENT THRU ROOF W - WASTE WCO - WALL CLEAN OUT WH - WALL HYDRANT WHA - WATER HAMMER ARRESTER W/TP - WITH TRAP PRIMER ALL WORK SHALL BE IN COMPLIANCE WITH THE FOLLOWING CODES, BUT NOT LIMITED TO: 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - BUILDING (FBCB) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - EXISTING BUILDING (FBCEB) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - ACCESSIBILITY (FBCA) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - ENERGY CONSERVATION (FBCEC) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - MECHANICAL (FBCM) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - PLUMBING (FBCP) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - FUEL GAS (FBCFG) 8TH EDITION OF THE 2023 FLORIDA FIRE PREVENTION CODE (FFPC) NFPA 70 - 2020 NATIONAL ELECTRICAL CODE (NEC) REVIEW SET David A. DaSilva 54739 CONSULTANTS: DATE PERMIT SET BID SET CONSTRUCTION SET AS BUILT APPROVED: SHEET NO.: CHECKED: DRAWN: DE S C R I P T I O N NO . DA T E REVISIONS Copyright 2024, DDC Engineering, Inc. 24085 MAY 14, 2024 SE B A S T I A N H A N G A R O F F I C E S B U I L D O U T SO U T H & N O R T H B A Y S O F H A N G A R D SE B A S T I A N M U N I C I P A L A I R P O R T SE B A S T I A N , F L O R I D A 3 2 9 5 8 4083 South U.S. Highway 1, Ste. 101 Rockledge, Florida 32955 Phone 321.633.4522 Fax 321.633.4528 www.ddc-engineers.com dasilva.david@ddc-engineers.com C.O.A.: 25988 DDC PROJECT NO.: This item has been electronically signed and sealed by David A. DaSilva, PE #54739. On May 14, 2024, using a Digital Signature. Printed copies of this document are not considered signed and sealed, and all SHA-1 authentication code and signature must be verified on any electronic copies. A.THE EXTENT OF DEMOLITION WORK SHOWN ON THE DRAWINGS ARE BASED ON EXISTING DRAWINGS AND FIELD SURVEY AND MAY NOT BE ALL INCLUSIVE. IT IS THE PLUMBING CONTRACTOR'S RESPONSIBILITY TO REMOVE ALL FIXTURES, PIPING AND OTHER EQUIPMENT AS MAY BE NECESSARY AND AT NO ADDITIONAL COST TO THE OWNER. B.ALL MEANS OF EGRESS SHALL BE KEPT OPEN AT ALL TIMES. C.CONTRACTOR SHALL COMPLY WITH APPLICABLE BUILDING CODES FOR ALL DEMOLITION WORK. D.PROCEED WITH DEMOLITION FROM TOP TO BOTTOM. DO NOT REMOVE ITEMS SUPPORTING OTHER MEMBERS WITHOUT PROVIDING TEMPORARY OR PERMANENT BRACING AS REQUIRED. E.EXISTING EQUIPMENT NOT REMOVED BUT DAMAGED DURING THE COURSE OF CONSTRUCTION SHALL BE RESTORED TO EXISTING CONDITION AT NO ADDITIONAL COST TO THE OWNER. F.PROTECT ITEMS AND EQUIPMENT ON SITE TO MINIMIZE DAMAGE. ANY DAMAGE INCURRED TO THE SITE SHALL BE REPAIRED BY THIS CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. G.REMOVAL OF ALL PIPING INCLUDES REMOVAL OF ALL SUPPORTS, HANGERS AND FASTENERS. PENETRATIONS LEFT BY THE REMOVAL OF PIPING SHALL BE PATCHED TO REMOVE THE APPEARANCE OF DEMOLITION. EXISTING PIPING NOT SHOWN TO BE REMOVED SHALL BE PROTECTED THROUGHOUT CONSTRUCTION. LEAKS IN PIPING RESULTING FROM DAMAGE DURING CONSTRUCTION SHALL BE PROMPTLY REPAIRED BY THIS CONTRACTOR. H.ALL MATERIALS AND EQUIPMENT SHALL BE DISPOSED OF IN ACCORDANCE WITH APPLICABLE LAWS AND ENVIRONMENTAL REGULATIONS. I.REFER TO ARCHITECTURAL DRAWINGS FOR FURTHER DEMOLITION REQUIREMENTS. CONTRACTOR TO PROPERLY REMOVE ALL PLUMBING SYSTEMS WHERE INDICATED AND PROPERLY TERMINATE ALL SYSTEMS. P-1 EED/SBH PL U M B I N G L E G E N D , N O T E S , S P E C S . & S C H E D U L E S JMF DAD PLUMBING SYMBOLS LEGEND, NOTES, AND SPECIFICATIONS PLUMBING LEGEND PLUMBING SPECIFICATIONS SHEET NOTE CALLOUT ABBREVIATIONS CODE COMPLIANCE REQUIREMENTS GENERAL DEMOLITION NOTES PROVIDE THE FOLLOWING: SCOPE OF WORK CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS AS REQUIRED TO PROVIDE A COMPLETE AND OPERATIONAL PLUMBING SYSTEMS AS INDICATED ON THE DRAWINGS. CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH ALL OTHER TRADES. SPECIAL PROVISIONS ALL WORK SHALL BE IN COMPLIANCE WITH THE 2023 FLORIDA BUILDING CODE (8TH EDITION), 2023 FLORIDA BUILDING CODE - PLUMBING (8TH EDITION), 2023 FLORIDA ENERGY CONSERVATION CODE (8TH EDITION), ORDINANCES AND REGULATIONS OF THE LOCAL AUTHORITY HAVING JURISDICTION. SHOP DRAWINGS BEFORE PURCHASE OR FABRICATION OF EQUIPMENT AND WITHIN 30 DAYS OF AWARD OF GENERAL CONTRACT, CONTRACTOR SHALL SUBMIT TO THE ARCHITECT/ENGINEER FOR APPROVAL, 3 COPIES OF SHOP DRAWINGS FOR ALL EQUIPMENT AND MATERIALS. SHOP DRAWINGS SHALL INDICATE WORKING AND ERECTION DIMENSIONS, ELECTRICAL CHARACTERISTICS (VOLTS, PHASE AND AMPS), LOCATION AT WHICH MATERIALS AND EQUIPMENT ARE TO BE INSTALLED AND OTHER ESSENTIAL DATA. PARTIAL OR INCOMPLETE SUBMITTALS WILL NOT BE ACCEPTED. ANY MATERIAL USED WITHOUT APPROVAL WILL BE REJECTED. PROVIDE SUBMITTALS ON ALL ITEMS EXCEPT PIPING. SUBMIT SHOP DRAWINGS TO ELECTRICAL CONTRACTOR FOR APPROVAL AND COORDINATION. MATERIALS MATERIALS, UNLESS OTHERWISE NOTED, SHALL BE NEW, FREE OF DEFECTS AND IN ACCORD WITH FOLLOWING SCHEDULES AND PARAGRAPHS. THE APPROVAL OF ANY MATERIALS WILL NOT BE CONSIDERED AS ACCEPTANCE OF WORK WHERE INSTALLED IF SUCH MATERIALS PROVE DEFECTIVE. WHERE NO SPECIFIC WEIGHTS OR GRADES ARE SPECIFIED, MATERIALS SHALL BE OF THE GENERALLY ACCEPTED STANDARD WEIGHT AND GRADE. DRAIN, WASTE AND VENT PIPING SANITARY PIPING SHALL BE SCHEDULE 40 PVC IN CONFORMANCE WITH ASTM F1488. WATER SYSTEM (DOMESTIC PIPING) ABOVE GROUND WATER PIPING SHALL BE TYPE "L" COPPER WITH SWEATED CONNECTIONS. BELOW GROUND PIPING SHALL BE TYPE "K" COPPER WITH SWEATED CONNECTIONS. PIPING SHALL BE IN CONFORMANCE WITH ASTM B88 A.SOLDER JOINTS WITH FREE FLOWING SOFT LEAD FREE SOLDER (95 5) PER ASTM B32 B.PIPING SHALL BE TESTED HYDROSTATICALLY AT A PRESSURE OF 150 PSIG. C.AFTER COMPLETION OF WORK, THE PIPING SHALL BE FLUSHED AND STERILIZED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE. D.INSULATE ALL HOT WATER PIPING WITH 1 2" ARMAFLEX. E.THE USE OF PEX PIPING IS NOT APPROVED. INSTALLATION PIPE SHALL BE CUT ACCURATELY TO MEASUREMENTS ESTABLISHED AT THE JOB SITE AND WORKED INTO PLACE WITHOUT FORCING, PROPERLY CLEARING ALL WINDOWS, DOORS, AND OTHER OPENINGS. PIPES SHALL HAVE BURRS REMOVED BY REAMING AND SHALL BE SO INSTALLED AS TO PERMIT FREE EXPANSION AND CONTRACTION WITHOUT DAMAGE TO JOINTS OR HANGERS. COMPRESSED AIR COPPER PIPING AND FITTINGS. OWNER MAY OPT TO USE SCHEDULE 40 PVC PIPE & FITTINGS. GAS PIPING SCHEDULE 40 BLACK IRON PIPE & FITTINGS. PAINT PIPING YELLOW AND LABEL. OPERATION AND MAINTENANCE INSTRUCTION COMPLETE OPERATING AND MAINTENANCE INSTRUCTIONS MANUALS FOR EACH PIECE OF EQUIPMENT, BOUND IN BOOK FORM, SHALL BE PREPARED. OPERATING INSTRUCTIONS EXPLAINING PREVENTIVE MAINTENANCE PROCEDURES, METHODS OF CHECKING THE SYSTEM FOR NORMAL SAFE OPERATION, AND PROCEDURE FOR SAFELY STARTING AND STOPPING THE SYSTEM SHALL BE PREPARED AND INCLUDED WITH THE MANUALS. GUARANTEE AND WARRANTIES A.FURNISH OWNER WITH A WRITTEN GUARANTEE PROTECTING THE OWNER FROM COSTS DUE TO POOR WORKMANSHIP AND FAULTY MATERIALS OR EQUIPMENT FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. B.FURNISH OWNER WITH ORIGINAL EQUIPMENT FACTORY WARRANTIES. TEST PIPING AT PRESSURE LISTED BELOW: A.HYDROSTATIC PRESSURE TEST: a.SANITARY AND ROOF DRAINAGE PIPING: TESTED UNDER THE REQUIREMENTS OF THE FBCP, BUT NOT LESS THAN EQUIVALENT TO 10 FEET OF WATER. b.WATER PIPING: 1-1/2 TIMES THE OPERATING PRESSURE, BUT NOT LESS THAN 100 PSIG AT THE TOP MOST OUTLET. DISINFECTION OF DOMESTIC WATER PIPING SYSTEM A.DISINFECTION SHALL BE PERFORMED AT EACH INDIVIDUAL BUILDING. B.ALL LEAD TESTING TO BE PERFORMED IN ACCORDANCE WITH EPA AND THE LOCAL COUNTY HEALTH DEPARTMENT STANDARDS AND REGULATIONS AND MEET OR EXCEED THEIR ALLOWABLE SAFE DRINKING WATER PARAMETERS. C.PRIOR TO STARTING WORK, VERIFY SYSTEM IS COMPLETE, FLUSHED AND CLEAN. D.ENSURE PH OF WATER TO BE TREATED IS CORRECT. E.INJECT DISINFECTANT, FREE CHLORINE IN LIQUID, POWDER, TABLET OR GAS FORM, THROUGHOUT SYSTEM TO OBTAIN 50 TO 80 MG/L RESIDUAL. F.MAINTAIN DISINFECTANT IN SYSTEM FOR 24 HOURS. G.IF FINAL DISINFECTANT RESIDUAL TESTS LESS THAN 25 MG/L, REPEAT TREATMENT. H.FLUSH DISINFECTANT FROM SYSTEM UNTIL RESIDUAL IS EQUAL TO THAT OF INCOMING WATER OR 1.0 MG/L. I.BLEED WATER FROM OUTLETS TO ENSURE DISTRIBUTION AND TEST FOR CONTAMINANTS AND LEAD CONTENT AT ALL THE REMOTE LOCATIONS AND AT SEVERAL INTERMEDIATE LOCATIONS. TEST LOCATIONS SHALL BE AT THE SERVICE ENTRY TO THE PROPERTY LINE, THE WATER ENTRY AT EACH BUILDING AND AT THE MOST REMOTE LOCATIONS OF THE CONSTRUCTED DOMESTIC WATER PIPING SYSTEM. J.TAKE WATER SAMPLE NO SOONER THAN 48 HOURS AFTER FLUSHING AT EACH BUILDING AND ANALYZE IN ACCORDANCE WITH AWWA C651. K.ALL WATER SAMPLES FOR LEAD SAMPLING SHALL BE 250 ML IN VOLUME. SAMPLING BOTTLES SHALL BE OBTAINED FROM THE CONTRACTOR'S CERTIFIED DRINKING WATER LABORATORY. L.TESTING OF THE WATER SAMPLES SHALL BE PERFORMED BY THE CONTRACTOR'S CERTIFIED DRINKING WATER LABORATORY IN COORDINATION WITH THE COUNTIES RISK MANAGEMENT DEPARTMENT. M.OWNER'S REPRESENTATIVE TO WITNESS ALL TEST. *ANY CHANGES TO THESE DOCUMENTS BASED ON CONTRACTOR REQUESTED REVISIONS SHALL BE CONSIDERED ADDITIONAL SERVICES. # POINT OF CONNECTION POINT OF DISCONNECT MISCELLANEOUS CONTROL VALVE HOT WATER PIPING HI-TEMP HOT WATER PIPING CONDENSATE CONNECTION, BOTTOM CONNECTION, TOP HW 140° CHECK VALVE STRAINER BUTTERFLY VALVE CALIBRATING BALANCING VALVE MIXING VALVE UNION VENT PIPING CW COLD WATER PIPING SANITARY WASTE PIPINGSS STORM DRAIN (TEMPERED) HOT WATER RECIRCULATION PIPINGHWR EWH-EQUIPMENT TAG GENERAL NOTES 1.ALL WORK AND MATERIALS SHALL BE PROVIDED AND INSTALLED IN COMPLIANCE WITH THE FLORIDA BUILDING CODES AND AS PER MANUFACTURERS INSTRUCTION. 2.PROVIDE SHUT-OFF VALVES FOR BOTH HOT AND COLD DOMESTIC WATER PIPING FEEDING GROUPS OF FIXTURES, AND AS PER FBC-P 606.1. 3.PROVIDE ALL EXTERIOR WALL HYDRANTS/BIBBS WITH SHUT-OFF BALL VALVES IMMEDIATELY INSIDE ABOVE THE CEILING OR OTHER ACCESSIBLE LOCATION. 4.PRIME AND PAINT ALL OUTSIDE PIPE AND PIPE SUPPORTS IF THEY ARE NOT GALVANIZED. 5.INSTALL WATER HAMMER ARRESTORS WHERE DIRECTED BY CODE. 6.PROVIDE CLEANOUTS AS DIRECTED BY FBC-P. 7.PROVIDE CLEANOUTS AT THE BASE OF ALL SEWER RISERS ON EACH FLOOR. 8.EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS. 9.FLOOR CLEAN OUTS SHALL BE INSTALLED FLUSH TO FINISHED FLOOR. INSTALL FLOOR CLEAN OUTS (FCO) AS CLOSE TO HIGH POINT AS POSSIBLE. NO DISHING PERMITTED. 10.ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12" FROM ANY VERTICAL SURFACE AND 10' FROM ANY OUTSIDE AIR INTAKES. 11.ALL PLUMBING WORK SHALL BE INSTALLED TO AVOID INTERFERENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING. INSTALL EQUIPMENT SUCH THAT REMOVAL DOES NOT REQUIRE REMOVAL OF CONNECTED PIPING. 12.BEFORE COMMENCEMENT OF WORK, CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALL UTILITIES AND PIPING, AND SHALL NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. 13.ALL WASTE AND VENT PIPING SHALL SLOPE AT 1/8" PER FOOT UNLESS INDICATED OTHERWISE. 14.INSULATE ALL EXPOSED PVC LOCATED IN RETURN AIR PLENUM SPACES WITH APPROVED FIRE WRAP INSULATION. 15.AVOID THE USE OF PLASTICS IN RETURN AIR PLENUMS. 16.ALL WASTE PIPING SHOWN ON THESE DRAWINGS IS LOCATED BELOW FLOOR SLAB (UNLESS NOTED OTHERWISE). ALL DOMESTIC WATER AND VENT PIPING IS LOCATED ABOVE THE CEILING (UNLESS NOTED OTHERWISE). GREASE WASTE PIPING COMPRESSED AIR PIPING GAS PIPING CD SD V GW A G GATE VALVE OR BALL VALVE ECO/FCO EXTERIOR CLEAN OUT AND FLOOR CLEAN OUT WALL CLEANOUTWCO FLOOR DRAIN FLOOR SINK FD- FS- NOTESMODEL MANUFACTURE / WASTEHW PIPE SIZE CWACCESSORIES DESCRIPTION /EQUIPMENT PLUMBING FIXTURE SCHEDULE VENT SK-1 SINK SINGLE STAINLESS STEEL (18 GA.) WITH GOOSENECK FAUCET 1/2"1/2"2"1-1/2" ELKAY LUSTERTONE SEE BELOW NOTES: TAG 1.PROVIDE SHUT OFF VALVES AND P-TRAPS AT ALL PLUMBING FIXTURES. 2.PROVIDE HANDICAP FIXTURES IN ALL HANDICAP DESIGNATED RESTROOMS. 3.ROUTE 5 8" DRAIN, 3 8" HW TO ALL DISHWASHERS FROM NEAREST SINK. 4.PROVIDE PRESSURE BALANCING VALVE AND ANTI-SCALD DEVICE FOR ALL SHOWERS AND TUBS. 5.COORDINATE SINK SIZE WITH CABINET INSTALLER. 6.PROVIDE ULTRA-COMPACT THERMOSTATIC MIXING VALVE, WITH TEMPERATURE GAUGE, FOR ALL LAVATORIES AND HAND SINKS, AS MANUFACTURED BY WEBSTONE. 7.CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL DRAWINGS FOR ALL FLOOR AND WALL MOUNTED FIXTURES. PROVIDED CARRIERS AS REQUIRED. 8.CONTRACTOR TO PROVIDE A SEPARATE COST FOR ALL PLUMBING FIXTURES IN BID PACKAGE. OWNER TO MAKE FINAL SELECTION OF FIXTURES. (CONTRACTOR TO COORDINATE WITH OWNER). WATER HAMMER ARRESTOR HANGERS / SUPPORTS PUMPS / CONTROLS INSULATION ALL FIXTURES ALL PLUMBING EQUIPMENT ITEM COPY FOR OWNER PRODUCT DATA SHOP DRAWINGS TEST REPORTS COORDINATION DRAWINGS WIRING DIAGRAMS O & M MANUAL 1 2 3 4 1 2 1 2 1 2 1 2 1 2 NOTES: 1- FOR REVIEW 2- FOR RECORD 3- COLOR SELECTION 4- SAMPLE NOTE: FOR ALL MATERIALS FOR CONSTRUCTION, INSTALLATION REQUIREMENTS AND TESTING REQUIREMENTS, REFER TO CONTRACT SPECIFICATIONS. CONTRACTOR SHALL SUBMIT ALL ITEMS UNDER ONE SUBMITTAL THAT REFERENCES DDC PROJECT NUMBER. NO PARTIAL SUBMITTALS WILL BE ACCEPTED. ALL SUBMITTALS SHALL BE EMAILED TO INFO@DDC-ENGINEERS.COM . REVIEW WATER HEATER PIPING / FITTINGS SHOP DRAWING SUBMITTALS N.T.S. FLOOR CLEANOUT DETAIL P-D006 FLOW PLUG IF END OF LINE CLEANOUT PLUG AND BODY. SEE SPECS. ADJUSTING COLLAR RISER 1 8 BEND FULL SIZE, 4" MAX. COVER FIN. FLOOR P4 N.T.S. DETAIL P-D006 FLOW PLUG IF END OF LINE CLEANOUT PLUG AND BODY. SEE SPECS. ADJUSTING COLLAR RISER 1 8 BEND FULL SIZE, 4" MAX. CONCRETE BASE SEWER LINE EXTERIOR CLEANOUT 2"-0" COVER EARTH 6" P3 FOR WALL CONST. SEE ARCH. DWGS. PLUG SCREW COUNTERSUNK CLEANOUT ACCESS COVER POLISHED S.S. LENGTH TO SUIT 1/8 BEND AT END WASTE LINE w/ OR VENT AS WASTE CLEANOUT MAY EXTEND TEE WASTE LINE OF LINE CLEANOUT WALL CLEANOUT DETAIL N.T.S. P P2 N.T.S. INSULATED PIPE HANGER DETAIL M-D009 SIZES UP TO 3" SINGLE MULTIPLE PIPE PIPE SADDLE (TYP.) ALL INSULATION PASSES THRU HANGER UNBROKEN LOCKNUT (TYP.) UNISTRUT OR ANGLE IRON WASHER (TYP.) PIPE SADDLE (18 GA., 18" LONG) ATTACH TO STRUCTURE CONTINUOUS THREADED ROD U-BOLT PIPE INSULATION PIPE P1 2 A A A.8 A.8 B.8 A.8 3 4 5 6 MGMT. OFFICE #1 107 MGMT. OFFICE #2 108 CONF. RM. 109 RECEPT. AREA 110 TRAINING #1 112 CORR. 111 TRAINING #2 113 TRAINING #3 114 TRAINING #4 115 FOYER 117CORR. 118 UTIL. RM. 119 R.R. 120 R.R. 121 PILOT BRIEFING RM. 123 CORR. 122 RECEPT. OFFICE 116 2" SS ECO SK-1 2" SS 1 2" CW/HW W1 P-2 1 S1 P-2 11 D D C B A A 10 9 C.2A.9 SIMULATOR AREA 100 OFFICE #1 101 OFFICE #2 102 BREAKROOM 103 UTILITY ROOM 104 R.R. 105 R.R. 106 SK-1 1 1 2" SS/ 1 2" CW/HW TO SK-1 S2 P-2 1 REVIEW SET David A. DaSilva 54739 CONSULTANTS: DATE PERMIT SET BID SET CONSTRUCTION SET AS BUILT APPROVED: SHEET NO.: CHECKED: DRAWN: DE S C R I P T I O N NO . DA T E REVISIONS Copyright 2024, DDC Engineering, Inc. 24085 MAY 14, 2024 SE B A S T I A N H A N G A R O F F I C E S B U I L D O U T SO U T H & N O R T H B A Y S O F H A N G A R D SE B A S T I A N M U N I C I P A L A I R P O R T SE B A S T I A N , F L O R I D A 3 2 9 5 8 4083 South U.S. Highway 1, Ste. 101 Rockledge, Florida 32955 Phone 321.633.4522 Fax 321.633.4528 www.ddc-engineers.com dasilva.david@ddc-engineers.com C.O.A.: 25988 DDC PROJECT NO.: This item has been electronically signed and sealed by David A. DaSilva, PE #54739. On May 14, 2024, using a Digital Signature. Printed copies of this document are not considered signed and sealed, and all SHA-1 authentication code and signature must be verified on any electronic copies. P-2 EED/SBH PL U M B I N G S E W E R P L A N JMF DAD #GENERAL NOTES 1.PROVIDE WATER HAMMER ARRESTORS FOR ALL PLUMBING FIXTURES. 2.CONTRACTOR TO CONFIRM PIPE SIZES, LOCATIONS AND FLOW. 3.PROVIDE SHUT OFF VALVES FOR EACH FIXTURE. 4.PROPERLY ANCHOR ALL PIPING TO STRUCTURE. 5.INSULATE ALL HOT WATER PIPES WITH 1" ARMAFLEX. 6.CONTRACTOR TO SAW CUT WALLS AND SLAB AS NECESSARY TO INSTALL NEW WORK. PROPERLY PATCH AND REPAIR. NORTH BAY 3/16" = 1'-0" PLUMBING PLAN S1 P-2 N.T.S. SEWER RISER DIAGRAM 1 2" CW/HW S2 P-2 N.T.S. SEWER RISER DIAGRAM 1 1 2" SS S K - 1 11 4" SK-1 11 4" VENT, CONNECT TO EXISTING 2" SS 2" SS ECO 1 2" CW/HW FROM EX. EWH WATER HAMMER ARRESTORS (TYP.) S K - 1 W1 P-2 N.T.S. WATER RISER DIAGRAM #PLAN NOTES 1.ROUTE 1/2" CW/HW TO SK-1 FROM NEAREST WATER HEADER. SOUTH BAY 3/16" = 1'-0" PLUMBING PLAN PP POWER POLE LOCATION - DATA & J-BOX LOCATE ABOVE CEILING. PROVIDE 10' ADDITIONAL WIRE FOR FIELD ADJUSTMENTS 2'x2' SURFACE MOUNTED FIXTURE 2'x4' RECESSED FIXTURE 2'x4' SURFACE MOUNTED FIXTURE 1'x4' RECESSED FIXTURE 4' WALL MOUNTED FIXTURE 4' FIXTURE 4' SUSPENDED FIXTURE 4' WALL MOUNTED FIXTURE WALL WASH LIGHT FIXTURE RECESSED DOWNLIGHT SURFACE MOUNTED DOWNLIGHT SUSPENDED PENDANT LIGHT FIXTURE DECORATIVE PENDANT FIXTURE HIGH BAY LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE EXTERIOR FLOOD LIGHT FIXTURE 8' FIXTURE 8' WALL MOUNTED FIXTURE POLE MOUNTED PARKING LOT LUMINARE CEILING MOUNTED TRACK LIGHTING CEILING MOUNTED EXIT SIGN WITH BATTERY BACKUP - SINGLE FACE - ARROW INDICATES DIRECTION WALL MOUNTED EXIT SIGN WITH BATTERY BACKUP - SINGLE FACE - ARROW INDICATES DIRECTION CEILING MOUNTED EXIT SIGN WITH BATTERY BACKUP - DOUBLE FACE - ARROW INDICATES DIRECTION EMERGENCY LIGHT WITH BATTERY BACKUP - DUAL HEAD COMBINATION EXIT / EMERGENCY LIGHT WITH BATTERY BACKUP (4) 4-WAY (2) DOUBLE POLE (D) DIMMER (DF) WALL BOX DIMMER (F) FAN RATED SWITCH (K) KEYED SWITCH CEILING MOUNTED OCCUPANCY SENSOR FIXTURES WITH DIAGONAL SHADING DENOTES EMERGENCY FIXTURE WITH INTEGRAL 1400 LUMEN BATTERY PACK OR BACKUP INVERTER. (NL INDICATES NIGHT LIGHT) DUPLEX GFI RECEPTACLE DUPLEX GFI RECEPTACLE MOUNTED ABOVE COUNTER QUAD RECEPTACLE QUAD RECEPTACLE MOUNTED ABOVE COUNTER QUAD GFI RECEPTACLE DUPLEX RECEPTACLE - FLUSH MOUNTED IN FLOOR BOX (WIREMOLD EVOLUTION SERIES OR EQUAL) DUPLEX GFI RECEPTACLE - FLUSH MOUNTED IN FLOOR BOX, WITH GASKETED COVER DUPLEX RECEPTACLE - FLUSH MOUNTED IN CEILING DUPLEX GFI RECEPTACLE - FLUSH MOUNTED IN CEILING QUAD RECEPTACLE - FLUSH MOUNTED IN FLOOR BOX (WIREMOLD EVELUTION SERIES OR EQUAL) QUAD GFI RECEPTACLE - FLUSH MOUNTED IN FLOOR BOX, WITH GASKETED COVER QUAD RECEPTACLE - FLUSH MOUNTED IN CEILING QUAD GFI RECEPTACLE - FLUSH MOUNTED IN CEILING, WITH GASKETED COVER SPECIAL PURPOSE OUTLET SPECIAL PURPOSE OUTLET MOUNTED ABOVE COUNTER SPECIAL PURPOSE OUTLET PLUG IN STRIP WITH RECEPTACLES 18" O.C. UNLESS NOTED OTHERWISE J-BOX J-BOX - FLUSH MOUNTED IN FLOOR FAN RATED J-BOX - FLUSH MOUNTED WITHIN CEILING EXHAUST FAN MOTOR COMBINATION EXHAUST FAN/LIGHT HOME RUN MOTOR OPERATED CEILING PADDLE FAN. PROVIDE CONNECTION BOX FOR WEIGHT OF FAN PLUS EF EXISTING COMM AND/OR DATA OUTLET EXISTING COMM AND/OR DATA OUTLET NEW COMM/DATA OUTLET WITH FLUSH MOUNTED 4" SQUARE SINGLE GANGE JUNCTION BOX 18"AFF UNLESS NOTED OTHERWISE. EXTEND 1" CONCEALED CONDUIT TO ABOVE ACCESSIBLE CEILING AND STUB-OUT WITH PLASTIC BUSHING OR AS NOTED. INSTALL PULL WIRE. NEW COMM/DATA OUTLET WITH FLUSH MOUNTED 4" SQUARE SINGLE GANGE JUNCTION BOX MOUNTED ABOVE COUNTER UNLESS NOTED OTHERWISE. EXTEND 1" CONCEALED CONDUIT TO ABOVE ACCESSIBLE CEILING AND STUB-OUT WITH PLASTIC BUSHING OR AS NOTED. INSTALL PULL WIRE. NEW COMM/DATA OUTLET JUNCTION BOX FLUSH MOUNTED WITHIN FLOOR. EXTEND 1" CONCEALED CONDUIT TO ABOVE ACCESSIBLE CEILING AND STUB-OUT WITH PLASTIC BUSHING OR AS NOTED. INSTALL PULL WIRE. NEW COMM/DATA OUTLET JUNCTION BOX FLUSH MOUNTED IN CEILING. EXTEND 1" CONCEALED CONDUIT TO ABOVE ACCESSIBLE CEILING AND STUB-OUT WITH PLASTIC BUSHING OR AS NOTED. REVISION REFERENCE # #WIRE CALLOUT TRANSFORMER BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, SURFACE MOUNTED BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, SURFACE MOUNTED INDICATES LIGHTING FIXTURE TYPE INDICATES SWITCH DESIGNATION INDICATES CIRCUIT NUMBER a A 14 LIGHT DASHED INDICATES EXISTING FIXTURE OR DEVICE DARK DASHED INDICATES EXISTING FIXTURE OR DEVICE RELOCATED DARK SOLID INDICATES NEW FIXTURE OR DEVICE HATCHED ITEMS INDICATES FIXTURE OR DEVICE TO BE REMOVED OR RELOCATED SYSTEM. PROVIDE PLUG LOAD CONTROLLABLE RECEPTACLES WITH PERMANENT MARKINGS PER NEC 406.3(E) AND "CONTROLLED". NOT IN CONTRACT (N.I.C.) KCMIL THOUSAND OF CIRCULAR MILS KVA KILOVOLT-AMPERES KW KILOWATT LTG LIGHTING MCM THOUSANDS OF CIRCULAR MILS MCB MAIN CIRCUIT BREAKER MCP MOTOR CIRCUIT PROTECTION MCU MASTER OR MOTOR CONTROL UNIT MH METAL HALIDE MLO MAIN LUG ONLY N NEUTRAL NA NOT APPLICABLE NEC NATIONAL ELECTRIC CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASS. NF NON-FUSED NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NL NIGHT LIGHT O.C.ON CENTER P POLE PNL PANELBOARD PVC POLYVINYL CHLORIDE RGS RIGID GALVANIZED STEEL RM ROOM RTU ROOF TOP UNIT SPEC SPECIFICATION SS SUPER SAVER OR STAINLESS STEEL TBB TELEPHONE/COMPUTER TERMINAL BOARD TYP TYPICAL UON UNLESS OTHERWISE NOTED V VOLTS VAV VARIABLE AIR VOLUME VFD VARIABLE FREQUENCY DRIVE W WIRE WP WEATHERPROOF A AMPERES AC ALTERNATING CURRENT OR AIR CONDITIONER ADA AMERICANS W/ DISABILITIES ACT AFC ABOVE FINISHED COUNTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AIC AMPS INTERRUPTING CAPACITY AWG AMERICAN WIRE GAUGE C CONDUIT CATV CABLE TELEVISION CH COUNTER HEIGHT COND CONDUIT CU COPPER OR CONDENSER UNIT DISC DISCONNECT ECB ENCLOSED CIRCUIT BREAKER EF EXHAUST FAN ELEC ELECTRICAL EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM EMT ELECTRICAL METALLIC TUBING ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EX EXISTING EXIST EXISTING FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL G GROUND GFI GROUND FAULT INTERRUPTER GND GROUND GRC GALVANIZED RIGID CONDUIT HVAC HEATING, VENTILATING AND AIR CONDITIONING J JUNCTION KAIC (THOUSAND) AMPERE INTERRUPTING CAPACITY LED COVE LIGHT FIXTURE LIGHTING SEQUENCE OF OPERATION CALLOUT #RISER EQUIPMENT NOTES POWER TO MODULAR FURNITURE. COORDINATE ALL REQUIREMENTS WITH FURNITURE SUPPLIER DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER WITH BOTTOM HALF CONTROLLED BY OCCUPANCY SENSOR/LIGHTING CONTROL SYSTEM. PROVIDE PLUG LOAD CONTROLLABLE RECEPTACLES WITH PERMANENT MARKINGS PER NEC 406.3(E) AND "CONTROLLED". J-BOX - WALL MOUNTED 1.ALL ELECTRICAL CONDUITS SHALL CARRY A SEPARATE GREEN INSULATED COPPER WIRE SIZED PER NEC UNLESS OTHERWISE INDICATED IN THE DRAWINGS. 2.COORDINATE ELECTRICAL REQUIREMENTS FOR ALL EQUIPMENT TO BE INSTALLED BY OTHER TRADES. 3.MULTIWIRE BRANCH CIRCUITS IN A SINGLE CONDUIT RUN SHALL BE ALLOWED. WIRE SIZES MIGHT REQUIRE UPSIZING FOR CONDUITS CONTAINING MORE THAN 3 CURRENT CARRYING CONDUCTORS, AS REQUIRED BY THE DERATING GUIDELINES OF ARTICLE 310.15 IN THE 2020 NEC. 4.BRANCH CIRCUIT FEEDER WIRE AND CONDUIT SIZES ARE INDICATED ON PANEL SCHEDULES. 5.RESTROOM EXHAUST FANS SHALL BE CONTROLLED BY RESTROOM LIGHT SWITCH. 6.REFER TO MECHANICAL PLANS FOR EXACT LOCATIONS AND REQUIREMENTS OF MECHANICAL EQUIPMENT. 7.EMERGENCY LIGHTING AND EXIT LIGHTING CONNECTED AHEAD OF LOCAL SWITCH. 8.FIRE ALARM DESIGN BY OTHERS. CONTRACTOR SHALL PROVIDE AND SUBMIT FULL SET OF FIRE ALARM DRAWINGS, DESIGNED, SIGNED AND SEALED BY A FLORIDA LICENSED ENGINEER. 9.COORDINATE SIGN LIGHT LOCATION WITH OWNER/ARCHITECT. 10.EXTERIOR LIGHTING AND SIGN LIGHTING SHALL BE CONTROLLED BY ASTRONOMICAL TIME CLOCK. 11.CONTRACTOR SHALL ENGAGE THE ENGINEER TO INSPECT COMPONENTS AND FUNCTION OF LIGHTING CONTROL SYSTEM INSTALLED, AS PER THE 8TH EDITION OF THE FLORIDA BUILDING CODE ENERGY CONSERVATION SECTION C405 AND C408.3.1. ADDITIONAL ENGINEERING FEES MAY APPLY. 12.WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER AND CODE OFFICIAL, INCLUDING A SINGLE LINE DIAGRAM OF THE BUILDING'S ELECTRICAL DISTRIBUTION, AS REQUIRED PER THE 8TH EDITION OF THE FLORIDA BUILDING CODE - ENERGY CONSERVATION C408.3.2. 13.ALL LIGHTING SHALL BE CONTROLLED BY OCCUPANCY SENSORS, AS MANUFACTURED BY WATT STOPPER OR EQUAL, UNLESS NOTED OTHERWISE. RESTROOMS EXHAUST FANS SHALL BE CONNECTED TO LIGHTING CIRCUIT AND CONTROL SWITCH UNLESS NOTED OTHERWISE. OCCUPANCY SENSORS TO BE DUAL TECHNOLOGY UNLESS NOTED OTHERWISE. CONTRACTOR SHALL CONSULT REPRESENTATIVE FOR TYPE AND PLACEMENT OF OCCUPANCY SENSORS AND PROVIDE SHOP DRAWINGS. 14.THIS PROJECT IS IN COMPLIANCE WITH 8TH EDITION FBC-EC C405.5.3 & NEC 210.19 WITH REGARDS TO VOLTAGE DROP FOR BOTH DISTRIBUTION PANEL & DOWNSTREAM BRANCH CIRCUITS. 15.AFTER WALLS ARE FRAMED, MARK ALL OUTLET, DATA, SWITCH, ETC. LOCATIONS ON THE GROUND AND CONFIRM LOCATION AND MOUNTING HEIGHTS WITH OWNER PRIOR TO ANY CONDUIT, ETC. IS INSTALLED. 16.PROVIDE TAMPER - RESISTANT RECEPTACLES AS REQUIRED PER NEC 406.12 17.SURGE PROTECTION DEVICES (SPD) SHALL BY PQ PROTECTION OR EQUAL. BRANCH PANELS: PQC160, DISTRIBUTION PANELS: PQC320, SERVICES 2500A AND LARGER: PQS300, SERVICES 3000A AND LARGER: PQS400. CONTRACTOR SHALL COORDINATE VOLTAGE REQUIRED FOR SURGE PROTECTION DEVICE(S). WHERE PANEL IS RECESSED, SPD SHALL BE RECESSED. INSTALL SPD PER MANUFACTURERS RECOMMENDATION. FLUSH MOUNTED TV OUTLET (WIREMOLD EVOLUTION EFS SERIES OR EQUAL) WITH RECEPTACLE, TV CONNECTION, AND DATA CONNECTION. EXTEND 1.5" CONCEALED CONDUIT, FOR TV AND DATA CABLE, TO ABOVE ACCESSIBLE CEILING AND STUB-OUT WITH PLASTIC BUSHING OR AS NOTED. INSTALL PULL REVIEW SET David A. DaSilva 54739 CONSULTANTS: DATE PERMIT SET BID SET CONSTRUCTION SET AS BUILT APPROVED: SHEET NO.: CHECKED: DRAWN: DE S C R I P T I O N NO . DA T E REVISIONS Copyright 2024, DDC Engineering, Inc. 24085 MAY 14, 2024 SE B A S T I A N H A N G A R O F F I C E S B U I L D O U T SO U T H & N O R T H B A Y S O F H A N G A R D SE B A S T I A N M U N I C I P A L A I R P O R T SE B A S T I A N , F L O R I D A 3 2 9 5 8 4083 South U.S. Highway 1, Ste. 101 Rockledge, Florida 32955 Phone 321.633.4522 Fax 321.633.4528 www.ddc-engineers.com dasilva.david@ddc-engineers.com C.O.A.: 25988 DDC PROJECT NO.: This item has been electronically signed and sealed by David A. DaSilva, PE #54739. On May 14, 2024, using a Digital Signature. Printed copies of this document are not considered signed and sealed, and all SHA-1 authentication code and signature must be verified on any electronic copies. (M) MOTOR RATED SWITCH - 1 OR 2 POLE 30 AMP WITH INTEGRAL THERMAL OVERLOADS (OC) WALL MOUNTED OCCUPANCY SENSOR SWITCH FIXTURES WITH DIAGONAL LINE DENOTES NIGHT LIGHT FIXTURE (NL INDICATES NIGHT LIGHT) A.THE CONTRACTOR SHALL VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE BUILDING AND SITE AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSAL SO AS TO BECOME FAMILIAR WITH EXISTING WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE BY DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. IT IS TO BE UNDERSTOOD THAT UNFORESEEN CONDITIONS PROBABLY EXIST AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON THE DRAWINGS. COOPERATION WITH OTHER TRADES IN EQUIPMENT ROUTING AS DETERMINED DURING CONSTRUCTION AND AS DIRECTED BY THE ARCHITECT/ENGINEER MAY BE NECESSARY AND IT IS INTENDED THAT SUCH DEVIATIONS SHALL BE CONSIDERED AS PART OF THIS CONTRACT. IT IS ALSO UNDERSTOOD THAT THE PLANS ARE NOT COMPLETELY TO SCALE. THIS CONTRACTOR IS TO FIELD VERIFY DIMENSIONS OF ALL EXISTING CONDITIONS, PRIOR TO BID AND INCLUDE ANY DEVIATIONS IN THE CONTRACT. B.ALL DEVICES AND EQUIPMENT NOT SHOWN AND IN AREAS OUTSIDE OF REMODELING SHALL REMAIN ACTIVE UNLESS OTHERWISE NOTED. INSTALL AS REQUIRED TO MAINTAIN CONTINUITY TO EXISTING DEVICES AND EQUIPMENT THAT ARE TO REMAIN. C.ALL EQUIPMENT AND MATERIAL REMOVED AND NOT REUSED SHALL BE TURNED OVER TO THE OWNER OR AT THE OWNERS REQUEST LEGALLY DISPOSED OF BY THE CONTRACTOR. D.ALL ELECTRICAL DEVICES THAT ARE REMOVED SHALL BE REMOVED AS DIRECTED BY THE OWNER, AND CEILING OR WALL SHALL BE PATCHED TO MATCH EXISTING OR NEW FINISH. ALL PATCHES OR CEILING PLATES SHALL BE PATCHED OR PAINTED AS DIRECTED BY ARCHITECTURAL DRAWINGS. E.ALL EXISTING ELECTRICAL EQUIPMENT IS NOT SHOWN. IT IS THE CONTRACTORS RESPONSIBILITY TO BECOME FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO BID, AND INCLUDE IN HIS BID THE REMOVAL OF ALL EQUIPMENT, CONDUIT, WIRE, ETC. THAT IS NOT BEING REUSED BACK TO ITS SOURCE. F.ALL CONCRETE, WALL PATCHING, CEILING REPAIR, AND OTHER GENERAL WORK REQUIRED FOR INSTALLING THE ELECTRICAL SYSTEMS AND TO REPAIR TO "LIKE NEW CONDITION" TO BE PROVIDED AND INSTALLED BY THE CONTRACTOR. G.PROVIDE AND INSTALL ANY ADDITIONAL HANGERS/SUPPORTS REQUIRED TO ACCOMMODATE ANY EQUIPMENT RELOCATIONS. H.COORDINATE ALL CEILING MOUNTED DEVICES WITH ARCHITECTURAL REFLECTED CEILING AND WORK OF ALL OTHER TRACES. I.FOR NEW ELECTRICAL DEVICES WITHIN EXISTING WALL PARTITIONS, CONTRACTOR SHALL BE PERMITTED TO USE METAL CLAD CABLE. PROVIDE SUBMITTAL PRIOR TO ROUGH-IN. J.ITEMS NOTED AS EXISTING TO BE REMOVED SHALL BE REMOVED COMPLETE. REMOVAL SHALL INCLUDE CONDUIT AND WIRE BACK TO BRANCH PANEL. K.FOR ALL PANELS AFFECTED BY RENOVATION, CONTRACTOR SHALL TRACK ALL EXISTING CIRCUITS AND REMOVE WIRING AND CONDUIT BACK TO PANEL FOR CIRCUITS NO LONGER IN USE. PROVIDE NEW TYPED PANEL DIRECTORY AND RELABEL ALL UNUSED CIRCUIT BREAKERS AS SPARE. L.THE WORK SHALL INCLUDE REVISIONS, DEMOLITION, MODIFICATIONS AND REWORK OF THE EXISTING FACILITY AND SYSTEMS AS REQUIRED FOR INSTALLATION OF NEW WORK, AND FOR CONNECTIONS BETWEEN EXISTING WORK AND NEW WORK WHERE REQUIRED. THE WORK SHALL ALSO INCLUDE THE COMPLETION OF ELECTRICAL POWER AND CONTROL CIRCUITS, FOR DEVICES AND EQUIPMENT THAT ARE TO REMAIN IN SERVICE, IF THE CIRCUITS ARE BROKEN BY DEMOLITION WORK, OR BY THE REMOVAL OR CUTTING OF EXISTING BUILDING CONSTRUCTION, EXISTING DEVICES OR EQUIPMENT. EXISTING CONDUIT WIRING SHALL BE REROUTED AND CONNECTED WHERE NECESSARY. E-1 EED EL E C T R I C A L L E G E N D , N O T E S , & S P E C I F I C A T I O N S JMF DAD ELECTRICAL SYMBOLS LEGEND, NOTES, AND SPECIFICATIONS LIGHTING 2'x2' RECESSED FIXTURE POWER(SEE LIGHTING FIXTURE SCHEDULE) DUPLEX RECEPTACLE DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER ELECTRICAL SPECIFICATIONS SWITCHES SINGLE POLE SWITCH - TOGGLE TYPE - MOUNT 48" AFF SUBSCRIPT INDICATES AS FOLLOWS: (a) FIXTURES CONTROLLED BY SWITCH (3) 3-WAY ELECTRICAL SERVICE SHUNT TRIP BREAK GLASS STATION ADDITIONAL 200 LBX. (BASIS OF DESIGN, INTERIOR: OCEANA OUTDOOR W LED LIGHT 52" FAN 100W; EXISTING COMM AND/OR DATA OUTLET 18"AFF EXISTING COMM AND/OR DATA OUTLET MOUNTED ABOVE COUNTER NL DATA/COMMUNICATION WALL MOUNTED OCCUPANCY SENSOR INSTALL PULL WIRE. SHEET NOTE CALLOUT SERVICE AND DISTRIBUTION NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH COMBINATION MOTOR STARTER/FUSED DISCONNECT SWITCH BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, RECESSED MOUNTED SURGE PROTECTION DEVICE (SPD) METER MISCELLANEOUS TIME CLOCK PHOTOCELL SENSOR CARD READER. DESIGN BY OTHERS. CONTRACTOR SHALL COORDINATE. SPEAKER. DESIGN BY OTHERS. CONTRACTOR SHALL COORDINATE. ABBREVIATIONS PHONE/DATA TO MODULAR FURNITURE. COORDINATE ALL REQUIREMENTS WITH FURNITURE SUPPLIER. SHOP DRAWING SUBMITTALS WIRE. COORDINATE MOUNTING HEIGHTS WITH OWNER PRIOR TO INSTALLATION. GENERAL DEMOLITION NOTES 1'x4' SURFACE MOUNTED FIXTURE 1'x4' SUSPENDED FIXTURE QUAD GFI RECEPTACLE MOUNTED ABOVE COUNTER DUPLEX RECEPTACLE WITH BOTTOM HALF CONTROLLED BY OCCUPANCY SENSOR/LIGHTING CONTROL GENERAL 1.ALL WORK SHALL BE IN ACCORDANCE WITH THE 2020 NATIONAL ELECTRICAL CODE (N.E.C.), 2023 FLORIDA ENERGY CONSERVATION CODE (8TH EDITION), ALL LOCAL CODES, ORDINANCES, REGULATIONS AND UTILITY POWER AND TELEPHONE COMPANY STANDARDS. 2.ALL WIRE SHALL BE COPPER TYPE "THHN" FOR SIZES UP TO #8 AND TYPE "THW FOR #6 AND LARGER (UNLESS OTHERWISE NOTED). MINIMUM WIRE SIZE SHALL BE #12 AWG. 3.ALL BRANCH AND FEEDER CIRCUITS SHALL CONTAIN A SEPARATE GROUNDING CONDUCTOR AND SHALL BE SIZED AND BONDED IN ACCORDANCE WITH ARTICLE 250 OF THE N.E.C. 4.ALL CONDUIT INSTALLED IN INTERIOR LOCATIONS SHALL BE TYP E.M.T. WITH COMPRESSION FITTING CONNECTORS AND COUPLINGS. ALL CONDUIT INSTALLED IN EXTERIOR LOCATIONS, ABOVE GRADE, SHALL BE GALVANIZED RIGID CONDUIT. ALL CONDUIT BELOW GRADE SHALL BE SCHEDULE 40 PVC. ALL CONDUITS SHALL BE CONCEALED. THE USE OF MC CABLE IS ACCEPTABLE. 5.CONTRACTOR TO COORDINATE THE LOCATION OF RECEPTACLES, CONTROL CIRCUITS, COMMUNICATIONS AND DATA OUTLETS, LIGHTING FIXTURES AND DEVICES WITH THE OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. 6.DRAWINGS ARE DIAGRAMMATIC - CONTRACTOR SHALL REFER TO ARCHITECTURAL, CIVIL AND STRUCTURAL DRAWINGS AND FIELD CONDITIONS FOR ALL DIMENSIONS. 7.CONTRACTOR SHALL OBTAIN AND FURNISH ALL PERMITS REQUIRED. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, APPLIANCES AND TOOLS TO PERFORM ALL WORK NECESSARY FOR THE COMPLETE EXECUTION OF THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS. PROVIDE WORK NOT SPECIFICALLY SHOWN OR SPECIFIED, YET REQUIRED TO INSURE PROPER AND COMPLETE OPERATION OF ALL SYSTEMS AND TO SATISFY THE DESIGN INTENT IN THE WORK AND TO COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS. 8.THE DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF CIRCUITS AND OUTLETS, LOCATIONS OF SWITCHES PANEL BOARDS, CONDUITS AND OTHER WORK. PRIOR FIELD VERIFICATION OF ALL DIMENSION IS REQUIRED. CONDUIT RUNS AND GROUNDING ARE SHOWN DIAGRAMMATICALLY ONLY. FIELD VERIFY ACTUAL ROUTING OF CONDUITS. 9.ANY PENETRATIONS MADE THROUGH A FIRE RATED ASSEMBLY SHALL BE PROPERLY SEALED TO MAINTAIN THE FIRE RATING OF THE ASSEMBLY PER U.L. AND NFPA. 10.THE WORK SHALL INCLUDE REVISIONS, DEMOLITION, MODIFICATIONS AND REWORK OF THE EXISTING FACILITY AND SYSTEMS AS REQUIRED FOR INSTALLATION OF NEW WORK, AND FOR CONNECTIONS BETWEEN EXISTING WORK AND NEW WORK WHERE REQUIRED. THE WORK SHALL ALSO INCLUDE THE COMPLETION OF ELECTRICAL POWER AND CONTROL CIRCUITS, FOR DEVICES AND EQUIPMENT THAT ARE TO REMAIN IN SERVICE, IF THE CIRCUITS ARE BROKEN BY DEMOLITION WORK, OR BY THE REMOVAL OR CUTTING OF EXISTING BUILDING CONSTRUCTION, EXISTING DEVICES OR EQUIPMENT. EXISTING CONDUIT WIRING SHALL BE REROUTED AND CONNECTED WHERE NECESSARY. 11.EACH BIDDER SHALL INSPECT THE SITE AS REQUIRED FOR KNOWLEDGE OF EXISTING CONDITIONS PRIOR TO BIDDING AND FAILURE TO OBTAIN SUCH KNOWLEDGE SHALL NOT RELIEVE THE SUCCESSFUL BIDDER OF THE RESPONSIBILITY TO MEET EXISTING CONDITIONS IN PERFORMING THE WORK UNDER THIS CONTRACT. 12.WHERE NEW WORK CANNOT BE INSTALLED WITHOUT CHANGES IN EXISTING FACILITY OR SYSTEMS OR WHERE IT IS INDICATED ON DRAWINGS TO REWORK AN EXISTING INSTALLATION, THIS CONTRACT SHALL INCLUDE ALTERATIONS TO EXISTING WORK AS REQUIRED TO INSTALL NEW WORK. ADDITIONS TO THE CONTRACT COST WILL NOT BE ALLOWED BECAUSE OF THIS CONTRACTORS FAILURE TO INSPECT EXISTING CONDITIONS AT THE SITE OF THE WORK. 13.PROVIDE HACR RATED CIRCUIT BREAKERS FOR ALL HVAC EQUIPMENT. 14.CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES TO MAINTAIN WORKING CLEARANCES AS REQUIRED PER NEC. AND FLORIDA BUILDING CODE. CUTTING AND PATCHING 1.THE RESPONSIBILITY FOR ANY CUTTING OF CONSTRUCTION WHICH IS REQUIRED FOR THE INSTALLATION OF ELECTRICAL WORK, SHALL BE BY THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND THE OWNER BEFORE ANY CUTTING AND OBTAIN APPROVAL FROM THE ARCHITECT/ENGINEER PRIOR TO ANY CUTTING. ALL PATCHING, PAINTING AND FINISH SHALL BE BY THE CONTRACTOR. 2.CUTTING SHALL BE DONE WITH EXTREME CARE AND IN SUCH A MANNER THAT THE STRENGTH OF THE STRUCTURE WILL NOT BE ENDANGERED. WHEREVER POSSIBLE, OPENINGS IN CONCRETE OR MASONRY CONSTRUCTION SHALL BE BY CONCRETE SAW OR ROTARY CORE DRILL. OPENINGS IN ANY CONSTRUCTION SHALL BE CUT THE MINIMUM SIZE REQUIRED FOR THE INSTALLATION OF THE WORK. ADEQUATE PROTECTION SHALL BE PROVIDED TO PREVENT DAMAGE TO ADJACENT AREAS AND TO PREVENT DUST FROM SPREADING TO ADJACENT AREAS. 3.WHERE OPENINGS OR HOLES ARE CUT IN CONSTRUCTION AND THE CUTTING BREAKS ELECTRICAL CIRCUITRY OR CONTROL CIRCUITRY CONDUIT AND WIRING, THEN IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REROUTE THE CIRCUITRY CONDUIT AND REWIRING AND TO COMPLETE THE CIRCUITRY AS REQUIRED AND AS APPROVED BY THE ARCHITECT/ENGINEER. TEMPORARY COMPLETION SHALL BE PROVIDED WHERE NECESSARY BEFORE THE PERMANENT REROUTING AND COMPLETION WORK IS FINISHED. 4.BEFORE ANY CUTTING, PATCHING, OR FINISHING WORK IS STARTED, DUST AND MOISTURE PROTECTION SHALL FIRST BE INSTALLED AS REQUIRED AND AS SPECIFIED IN THESE SPECIFICATIONS. 5.OPENINGS CUT IN FLOOR SHALL BE CUT BY CORE DRILLING WHERE POSSIBLE. AFTER WORK IS INSTALLED THROUGH ANY OPENING IN FLOOR, THE OPENING AROUND THE WORK SHALL BE PATCHED AND SEALED WATERTIGHT WITH EPOXY OR SILICONE BASED, NON-CRACKING ELASTOMERIC SEALANT. PAINTING 1.CONTRACTOR SHALL BE RESPONSIBLE FOR REPAINTING AREAS OF CONSTRUCTION THAT ARE SCRATCHED, MARRED, OR DAMAGED BY THE NEW CONSTRUCTION. CONTRACTOR SHALL MATCH THE COLOR, TYPE AND THICKNESS OF PAINT AS PREVIOUS. ACCEPTANCE TESTING 1.UPON COMPLETION OF WORK, THE ENTIRE WIRING SYSTEM SHALL BE TESTED, AND SHALL BE SHOWN TO BE IN PROPER WORKING CONDITION IN ACCORDANCE WITH INTENT OF SPECIFICATIONS AND DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE ALL SYSTEMS READY FOR OPERATION AND TO HAVE AN ELECTRICIAN AVAILABLE TO OPERATE SAME IN ACCORDANCE WITH AND UNDER THE SUPERVISION OF THE INSPECTION REPRESENTATIVE OF THE ARCHITECT/ENGINEER. THE CONTRACTOR SHALL BE AVAILABLE TO ASSIST IN REMOVAL OF PANEL FRONTS, ETC., TO PERMIT INSPECTION AS REQUIRED. AS-BUILT DRAWINGS 1.THE CONTRACTOR SHALL PROVIDE AND KEEP UP TO DATE A COMPLETE RECORD SET OF CONSTRUCTION "AS-BUILTS" BLUE LINE PRINTS WHICH SHALL BE CORRECTED DAILY, AND SHALL SHOW EVERY CHANGE FROM THE ORIGINAL CONTRACT DRAWINGS, INCLUDING ADDENDA AND CHANGE ORDERS IN ACCORDANCE WITH GENERAL REQUIREMENTS AND SPECIAL CONDITIONS. THIS SET OF PRINTS SHALL BE KEPT ON THE JOB SITE, AND SHALL BE USED ONLY AS A RECORD SET. THIS SHALL NOT BE CONSTRUED AS AUTHORIZATION FOR THE CONTRACTORS TO MAKE CHANGES IN THE LAYOUT WITHOUT DEFINITE INSTRUCTION IN EACH CASE. PROTECTION 1.THE CONTRACTOR SHALL KEEP THE CONSTRUCTION SITE CLEAN OF ALL WASTE MATERIALS AND RUBBISH CAUSED BY HIS WORK OR EMPLOYEES. UPON COMPLETION OF THE WORK AND AT TIMES DURING PROGRESS OF THE WORK WHEN REQUESTED BY THE ARCHITECT/ENGINEER, THE CONTRACTOR SHALL REMOVE ALL SURPLUS MATERIALS, RUBBISH, AND DEBRIS RESULTING FROM THE OPERATION, AND SHALL LEAVE THE ENTIRE BUILDING AND INVOLVED PORTIONS OF THE SITE, INSOFAR AS THE WORK OF THE CONTRACT IS CONCERNED, IN A NEAT, CLEAN, AND ACCEPTABLE CONDITION AS APPROVED BY THE ARCHITECT/ENGINEER. EQUIPMENT, LIGHTING FIXTURES, MATERIALS AND ACCESSORIES SHALL BE THOROUGHLY CLEANED OF CEMENT, PLASTER, AND OTHER MATERIALS. 2.THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION, WHEREVER WORK IS TO BE PERFORMED IN FINISHED/OCCUPIED SPACES, TO PREVENT DAMAGE TO ADJACENT AREAS, EQUIPMENT, OR FURNISHINGS; TO PREVENT ACCIDENTAL INJURY TO BUILDING OCCUPANTS AND THE PUBLIC; TO PREVENT THE SPREADING OF DUST, DIRT, DEBRIS, AND MOISTURE FROM THE AREA WHERE WORK IS BEING PERFORMED; AND TO PREVENT DUST, DIRT, DEBRIS, AND MOISTURE FROM GETTING ON OR IN THE BUILDING OCCUPANTS FURNISHINGS OR EQUIPMENT. 3.THE CONTRACTOR SHALL REPAIR, AT NO COST TO THE OWNER, ANY DAMAGE DONE BY HIMSELF OR HIS EMPLOYEES. HE SHALL ALSO BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED TO PROPERLY INSTALL HIS WORK. THIS SHALL ALSO INCLUDE THE PATCHING OF EXISTING ROADWAYS (PAVED OR IMPROVED), PARKING AREAS, SIDEWALKS, CURBS, GUTTERS, ETC., CUT TO INSTALL WORK PROVIDED BY THE CONTRACTOR. PATCH WORK SHALL COMPLY WITH THE APPLICABLE SECTIONS OF THESE SPECIFICATIONS AND SHALL MATCH THE EXISTING FINISHES. # PNL P EQUIPMENT TAG WIRELESS ACCESS POINT DESIGN BY OTHERS. CONTRACTOR SHALL COORDINATE EXTERIOR: HUNTER JETTY OUTDOOR 52" FAN 100W; EQUALS ARE ACCEPTABLE) POINT OF DISCONNECT POINT OF CONNECTION ITEM COPY FOR OWNER PRODUCT DATA SHOP DRAWINGS TEST REPORTS COORDINATION DRAWINGS WIRING DIAGRAMS O & M MANUAL 1 SUBMITTAL TYPE: 1.FOR REVIEW 2.FOR RECORD 3.COLOR SELECTION 4.SAMPLE REMARKS: 1.FOR ALL MATERIALS FOR CONSTRUCTION, INSTALLATION REQUIREMENTS AND TESTING REQUIREMENTS, REFER TO CONTRACT SPECIFICATIONS. 2.BEFORE PURCHASE OR FABRICATION OF EQUIPMENT AND WITHIN 30 DAYS OF AWARD OF GENERAL CONTRACT, CONTRACTOR SHALL SUBMIT TO THE ARCHITECT/ENGINEER FOR APPROVAL, PDF COPIES OF SHOP DRAWINGS FOR ALL EQUIPMENT, LIGHTING, DEVICES, AND MATERIALS. PARTIAL OR INCOMPLETE SUBMITTALS WILL NOT BE ACCEPTED. ANY MATERIAL USED WITHOUT APPROVAL WILL BE REJECTED. SUBMIT SHOP DRAWINGS TO MECHANICAL AND PLUMBING CONTRACTOR FOR APPROVAL AND COORDINATION. 3.AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER, WITHIN 90 DAYS OF THE DAY OF RECEIVING THE CERTIFICATE OF OCCUPANCY, PER 8TH EDITION OF THE FLORIDA BUILDING CODE - ENERGY CONSERVATION C408.3.2.2. INCLUDE AT A MINIMUM THE FOLLOWING: a)SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. b)OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. c)NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY. 5.ELECTRICAL GEAR INCLUDES ALL SWITCHBOARDS, PANELBOARDS, TRANSFORMERS, SURGE PROTECTION DEVICES, MOTOR CONTROLLERS, DISCONNECTS, ETC. 6.ALL SUBMITTALS SHALL BE EMAILED TO INFO@DDC-ENGINEERS.COM . 7.CONTRACTOR SHALL SUBMIT ALL ITEMS UNDER ONE SUBMITTAL THAT REFERENCES DDC PROJECT NUMBER. NO PARTIAL SUBMITTALS WILL BE ACCEPTED. REVIEW ALL WORK SHALL BE IN COMPLIANCE WITH THE FOLLOWING CODES, BUT NOT LIMITED TO: 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - BUILDING (FBCB) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - EXISTING BUILDING (FBCEB) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - ACCESSIBILITY (FBCA) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - ENERGY CONSERVATION (FBCEC) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - MECHANICAL (FBCM) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - PLUMBING (FBCP) 8TH EDITION OF THE 2023 FLORIDA BUILDING CODE - FUEL GAS (FBCFG) 8TH EDITION OF THE 2023 FLORIDA FIRE PREVENTION CODE (FFPC) NFPA 70 - 2020 NATIONAL ELECTRICAL CODE (NEC) CODE COMPLIANCE REQUIREMENTS 2 3 4 1 2 1 2 1 2 1 2 1 2 ELECTRICAL GEAR GROUNDING DEVICES CONDUIT/FITTINGS FEEDERS WIRING DEVICES LIGHTING LIGHTING CONTROLS GENERAL NOTES 2 A A A.8 A.8 B.8 A.8 3 4 5 6 MGMT. OFFICE #1 107 MGMT. OFFICE #2 108 CONF. RM. 109 RECEPT. AREA 110 TRAINING #1 112 CORR. 111 TRAINING #2 113 TRAINING #3 114 TRAINING #4 115 FOYER 117CORR. 118 UTIL. RM. 119 R.R. 120 R.R. 121 PILOT BRIEFING RM. 123 CORR. 122 RECEPT. OFFICE 116 DA-42 DA-44 DA-42 DA-42 DA-42 DA-40 DA-40 DA-40 DA-40 DA-40 DA-38 DA-38 DA-38 DA-38 DA-36 DA-36 DA-27 DA-27 DA-27 DA-27 DA-25 DA-25 DA-25 DA-25 DA-31 DA-33 DA-35 DA-37 DA-29 DA-29 DA-29 72"AFF DA-29 DA-46 DA-46 60"AFF DA-46 DA-46 DA-46 DA-46 DA-46 DA-44 DA-46 AC-2N AC-1N DA-23 DA-43:45 DA-39:41 EX. PNL DA DA-36 DA-46 DA-44 DB-39 WP DA-51:53 CU-2N DA-43:49 WP DB-23 CU-1N DA-38 11 D D C B A A 10 9 C.2A.9 SIMULATOR AREA 100 OFFICE #1 101 OFFICE #2 102 BREAKROOM 103 UTILITY ROOM 104 R.R. 105 R.R. 106 DB-41 DB-41 DB-43 DB-41 DB-41 DB-36 DB-36 DB-38 DB-34 DB-34 DB-34 DB-32 DB-34 DB-32DB-32DB-32DB-45 DB-45 DB-43 DB-43 DB-43 DB-45DB-45 DA-39 DA-47:49 DB-39 WP DA-51:53 EX. PNL DB EX AC-1S EX CU-1S REVIEW SET David A. DaSilva 54739 CONSULTANTS: DATE PERMIT SET BID SET CONSTRUCTION SET AS BUILT APPROVED: SHEET NO.: CHECKED: DRAWN: DE S C R I P T I O N NO . DA T E REVISIONS Copyright 2024, DDC Engineering, Inc. 24085 MAY 14, 2024 SE B A S T I A N H A N G A R O F F I C E S B U I L D O U T SO U T H & N O R T H B A Y S O F H A N G A R D SE B A S T I A N M U N I C I P A L A I R P O R T SE B A S T I A N , F L O R I D A 3 2 9 5 8 4083 South U.S. Highway 1, Ste. 101 Rockledge, Florida 32955 Phone 321.633.4522 Fax 321.633.4528 www.ddc-engineers.com dasilva.david@ddc-engineers.com C.O.A.: 25988 DDC PROJECT NO.: This item has been electronically signed and sealed by David A. DaSilva, PE #54739. On May 14, 2024, using a Digital Signature. Printed copies of this document are not considered signed and sealed, and all SHA-1 authentication code and signature must be verified on any electronic copies. E-2 EED EL E C T R I C A L P O W E R P L A N JMF DAD NORTH BAY 3/16" = 1'-0" ELECTRICAL POWER PLAN SOUTH BAY 3/16" = 1'-0" ELECTRICAL POWER PLAN 2 A A A.8 A.8 B.8 A.8 3 4 5 6 MGMT. OFFICE #1 107 MGMT. OFFICE #2 108 CONF. RM. 109 RECEPT. AREA 110 TRAINING #1 112 CORR. 111 TRAINING #2 113 TRAINING #3 114 TRAINING #4 115 FOYER 117 CORR. 118 UTIL. RM. 119 R.R. 120 R.R. 121 PILOT BRIEFING RM. 123 CORR. 122 RECEPT. OFFICE 116 DA-15 A NL DA-34 A A DA-15 A a a DA-15 A a DA-15 A a DA-34 A DA-34 A DA-34 A DA-15 A NL DA-34 A A DA-34 a A DA-34 a A DA-34 a A DA-34 a C b DA-34 C b DA-34 a DA-34 A DA-15 b A DA-15 b A DA-15 b A DA-15 a A DA-15 bA DA-15 NL A DA-15 b A DA-15 b A DA-15 b A DA-15 b A DA-15 bA DA-15 bA DA-15 b A DA-15 a A DA-15 a b a A DA-15 c A DA-15 c A DA-15 c A DA-15 aA DA-15 NL A DA-15 A DA-15 a A DA-15 aA DA-15 a EF. EX EF. EX EF. EX a A DA-34 A DA-34 A DA-34 A DA-34 A DA-34 A DA-34 A DA-34 A DA-15 11 D D C B A A 10 9 C.2A.9 SIMULATOR AREA 100 OFFICE #1 101 OFFICE #2 102 BREAKROOM 103 UTILITY ROOM 104 R.R. 105 R.R. 106 A DB-9 EF. EX EF. EX A DB-9 1TYP. A DB-9 A DB-9 A DB-9 A DB-9 NL A DB-9 B DB-9 EF. EX B DB-9 NL B DB-9 B DB-9 REVIEW SET David A. DaSilva 54739 CONSULTANTS: DATE PERMIT SET BID SET CONSTRUCTION SET AS BUILT APPROVED: SHEET NO.: CHECKED: DRAWN: DE S C R I P T I O N NO . DA T E REVISIONS Copyright 2024, DDC Engineering, Inc. 24085 MAY 14, 2024 SE B A S T I A N H A N G A R O F F I C E S B U I L D O U T SO U T H & N O R T H B A Y S O F H A N G A R D SE B A S T I A N M U N I C I P A L A I R P O R T SE B A S T I A N , F L O R I D A 3 2 9 5 8 4083 South U.S. Highway 1, Ste. 101 Rockledge, Florida 32955 Phone 321.633.4522 Fax 321.633.4528 www.ddc-engineers.com dasilva.david@ddc-engineers.com C.O.A.: 25988 DDC PROJECT NO.: This item has been electronically signed and sealed by David A. DaSilva, PE #54739. On May 14, 2024, using a Digital Signature. Printed copies of this document are not considered signed and sealed, and all SHA-1 authentication code and signature must be verified on any electronic copies. E-3 EED EL E C T R I C A L L I G H T I N G P L A N JMF DAD NORTH BAY 3/16" = 1'-0" ELECTRICAL LIGHTING PLAN INTERIOR LIGHTING POWER DENSITY ENERGY USE VS. ALLOWANCE SUMMARY - FBC C405.3.2(1)/C405.3.2(2) OFFICE CORRIDOR TOTAL ALLOWANCE LUMINARIES AREA (Sq.Ft.) ALLOWED (W/Sq.Ft.) ALLOWED WATTS #TYPE WATT DESIGNED WATTS DESIGNED (W/Sq.Ft.) 483 517.6 0.74 320.4 9 A 35.8 322.2 0.41 212.2 4 A 35.8 1791.1 AREA CONFERENCE ROOM 284 0.97 275.5 2 C 20 TRAINING ROOM 471 0.71 334.4 6 A 35.8 143.2 40 214.8 1722 RECEPTION 814 0.84 683.8 SOUTH BAY 3/16" = 1'-0" ELECTRICAL LIGHTING PLAN 1.PROVIDE ALL EMERGENCY DEVICES WITH BATTERY BACKUP, MINIMUM 90 MINUTES. 2.EXIT SIGNS SHALL BE PROVIDE WITH ARROWS AS DIRECTED ON PLANS. 3.CONTRACTOR SHALL COORDINATE ALL RECESSED LIGHTING WITH CEILING TYPES AND PROVIDE DRYWALL KITS AS REQUIRED. 4.CONTRACTOR SHALL COORDINATE ALL EXTERIOR FIXTURE FINISHES WITH ARCHITECT/OWNER PRIOR TO PURCHASING. 5.ALL LIGHTING SHALL BE CONTROLLED BY SENSORSWITCH OR EQUAL. MARK DESCRIPTION QTY. LAMPS WATTS TYPE DIFFUSER MOUNTING VOLTAGE MANUFACTURER NOTES: LIGHTING SCHEDULE B 1x4 RECESSED FLAT PANEL LED FIXTURE 33.7 LED ACRYLIC RECESSED UNV LITHONIA CPX 1X4 AL07 SWW7 M4 A 2x2 RECESSED FLAT PANEL LED FIXTURE 35.8 LED ACRYLIC RECESSED UNV LITHONIA CPX 2X2 AL07 SWW7 M4 C 4" RECESSED DOWNLIGHT 20 LED 3500K RECESSED UNV WILLIAMS 4DR-TL-L20/835-DIM-UNV-OW-OF-CS-N-F1 12 A 35.8 429.6 16 A 35.8 572.8 INTERIOR LIGHTING POWER DENSITY ENERGY USE VS. ALLOWANCE SUMMARY - FBC C405.3.2(1)/C405.3.2(2) OFFICE CORRIDOR TOTAL ALLOWANCE LUMINARIES AREA (Sq.Ft.) ALLOWED (W/Sq.Ft.) ALLOWED WATTS #TYPE WATT DESIGNED WATTS DESIGNED (W/Sq.Ft.) 182 73 0.74 134.7 4 A 35.8 143.2 0.41 29.9 1002.3 AREA TRAINING ROOM 1120 0.71 795.2 4 B 33.7 BREAK ROOM 72 0.59 42.5 1 A 35.8 134.8 35.8 385.4 2 A 35.8 71.6 REVIEW SET David A. DaSilva 54739 CONSULTANTS: DATE PERMIT SET BID SET CONSTRUCTION SET AS BUILT APPROVED: SHEET NO.: CHECKED: DRAWN: DE S C R I P T I O N NO . DA T E REVISIONS Copyright 2024, DDC Engineering, Inc. 24085 MAY 14, 2024 SE B A S T I A N H A N G A R O F F I C E S B U I L D O U T SO U T H & N O R T H B A Y S O F H A N G A R D SE B A S T I A N M U N I C I P A L A I R P O R T SE B A S T I A N , F L O R I D A 3 2 9 5 8 4083 South U.S. Highway 1, Ste. 101 Rockledge, Florida 32955 Phone 321.633.4522 Fax 321.633.4528 www.ddc-engineers.com dasilva.david@ddc-engineers.com C.O.A.: 25988 DDC PROJECT NO.: This item has been electronically signed and sealed by David A. DaSilva, PE #54739. On May 14, 2024, using a Digital Signature. Printed copies of this document are not considered signed and sealed, and all SHA-1 authentication code and signature must be verified on any electronic copies. E-4 EED EL E C T R I C A L P A N E L S C H E D U L E S JMF DAD TOTAL DESIGN LOADDFLFCONN. LOADEQUIPMENT SERVED 1 CKT. BKR.KVA POLE/TR Ø N GND C BRANCH CKTNOTESCKT NO.Ø AMPS CNO. CKT BRANCH CKT GNDNØPOLE/TRKVACKT. BKR. A B C 3 5 7 15 13 11 9 C B A C B A C B A C B A C B A C B A 25 27 29 31 23 21 19 17 41 39 37 35 33 2 34 36 38 40 42 18 20 22 24 32 30 28 26 10 12 14 16 8 6 4 EQUIP NO.EQUIPMENT SERVED EQUIP NO.EQUIPMENT SERVED NOTES C B A 47 45 43 44 46 48 C B A 53 51 49 50 52 54 TYPE PANEL TYPE: PANEL LOCATION: FED FROM SOURCE: TYPE BUS AMP RATING: MAIN TYPE: VOLTAGE: PHASE: WIRE: LUG LOCATION: MOUNTING: AIC RATING: MAIN AMP RATING: NOTES: TC -WIRE THROUGH CONTACTOR HACR -HACR TYPE BREAKER LO -LOCKOUT BREAKER GFCI -GND FAULT CURRENT INTERRUPT CIRCUIT BREAKER IG -ISOLATED GROUND WIF -WALK IN FREEZER WIC -WALK IN COOLER CONNECTION TYPE R - RECEPTACLE L - LIGHTING H - HVAC/EWH K - KITCHEN EQUIPMENT M - MISC. PANEL: 120/208 3 4 DA (EXISTING) EXISTING UTILITY #115 MAIN DISCONNECT #2 225 A 200 A MLO EXISTING EXISITNG EXISITNG REMARKS: -PROVIDE NEW TYPE WRITTEN DIRECTORY. -CONTRACTOR SHALL CONFIRM HVAC CIRCUIT BREAKER REQUIREMENTS BEFORE PURCHASING. -HEAT/COOLING LOADS ARE MUTUALLY EXCLUSIVE. -PROVIDE FAULT CURRENT MARKER PER NEC 110.24 -PROVIDE ARC-FLASH DECALS PER NEC 110.16. -AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH OR EXCEED AIC RATING OF EXISTING CIRCUIT BREAKERS. RECEPTACLES (FIRST 10 KVA)10.0 1.00 10.0 RECEPTACLES (REMAINING KVA)11.13 0.50 5.57 LIGHTING 8.27 1.25 10.33 HVAC/EWH 21.6 1.00 21.6 KITCHEN EQUIPMENT 0 1.00 0 MISC.0 1.00 0 47.5 KVA 132 R AC-1,2N / CU-1N, 2N SERVICE REC..540 1/20 12 12 12 1/2" R PILOT BRIEFING .900 1/20 12 12 12 1/2" R RECEPTION .900 1/20 12 12 12 1/2" R RECEPTION .900 1/20 12 12 12 1/2" R RECEPTION COUNTER .720 1/20 12 12 12 1/2" RECEPTION COUNTER 1.00 1/20 12 12 12 1/2" RECEPTION COUNTER 1.00 1/20 12 12 12 1/2" RECEPTION COUNTER 1.00 1/20 12 12 12 1/2" H AC-1N HACR 10.0 2/60 6 -10 1" 6 H AC-2N HACR 10.0 2/60 6 -10 1" 6 H CU-1N HACR 5.00 2/50 8 -10 1" 8 H CU-1N HACR 5.00 2/50 8 -10 1" 8 L GENERAL/ EMERGENCY .650 1/20 12 12 12 1/2" R RECEPTION OFFICE .540 1/20 12 12 12 1/2" R TRAINING #3 & #4 .900 1/20 12 12 12 1/2" R TRAINING #1 & #2 .720 1/20 12 12 12 1/2" R MGNT. OFFICE #1 .900 1/20 12 12 12 1/2" R MGNT. OFFICE #2 .900 1/20 12 12 12 1/2" R CONF. RM 1.44 1/20 12 12 12 1/2" TOTAL DESIGN LOADDFLFCONN. LOADEQUIPMENT SERVED 1 CKT. BKR.KVA POLE/TR Ø N GND C BRANCH CKTNOTESCKT NO.Ø AMPS CNO. CKT BRANCH CKT GNDNØPOLE/TRKVACKT. BKR. A B C 3 5 7 15 13 11 9 C B A C B A C B A C B A C B A C B A 25 27 29 31 23 21 19 17 41 39 37 35 33 2 34 36 38 40 42 18 20 22 24 32 30 28 26 10 12 14 16 8 6 4 EQUIP NO.EQUIPMENT SERVED EQUIP NO.EQUIPMENT SERVED NOTES C B A 47 45 43 44 46 48 C B A 53 51 49 50 52 54 TYPE PANEL TYPE: PANEL LOCATION: FED FROM SOURCE: TYPE BUS AMP RATING: MAIN TYPE: VOLTAGE: PHASE: WIRE: LUG LOCATION: MOUNTING: AIC RATING: MAIN AMP RATING: NOTES: TC -WIRE THROUGH CONTACTOR HACR -HACR TYPE BREAKER LO -LOCKOUT BREAKER GFCI -GND FAULT CURRENT INTERRUPT CIRCUIT BREAKER IG -ISOLATED GROUND WIF -WALK IN FREEZER WIC -WALK IN COOLER CONNECTION TYPE R - RECEPTACLE L - LIGHTING H - HVAC/EWH K - KITCHEN EQUIPMENT M - MISC. PANEL: 120/208 3 4 DB (EXISTING) EXISTING UTILITY ROOM 104 MAIN DISC. #1 225 A 200 A MLO EXISTING EXISTING EXISTING RECEPTACLES (FIRST 10 KVA)10.0 1.00 10.0 RECEPTACLES (REMAINING KVA)10.14 0.50 5.07 LIGHTING 4.76 1.25 5.95 HVAC/EWH 13.2 1.00 13.2 KITCHEN EQUIPMENT 0 1.00 0 MISC.0 1.00 0 34.2 KVA 95 REMARKS: -PROVIDE NEW TYPE WRITTEN DIRECTORY. -CONTRACTOR SHALL CONFIRM HVAC CIRCUIT BREAKER REQUIREMENTS BEFORE PURCHASING. -HEAT/COOLING LOADS ARE MUTUALLY EXCLUSIVE. -PROVIDE FAULT CURRENT MARKER PER NEC 110.24 -PROVIDE ARC-FLASH DECALS PER NEC 110.16. -AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH OR EXCEED AIC RATING OF EXISTING CIRCUIT BREAKERS. R AC-1S & CU-1S DERVICE REC..360 1/20 12 12 12 1/2" R OFFICE #1 .720 1/20 12 12 12 1/2" R OFFICE #2 .720 1/20 12 12 12 1/2" R SIMULATOR AREA .720 1/20 12 12 12 1/2" H AC-1S HACR 10.0 2/60 6 -10 1" 6 H CU-1S HACR 5.00 2/50 8 -10 1" 8 R SIMULATOR AREA .720 1/20 12 12 12 1/2" R SIMULATOR AREA .720 1/20 12 12 12 1/2" R BREAK ROOM 1.00 1/20 12 12 12 1/2" R BREAK ROOM 1.00 1/20 12 12 12 1/2" (E) - EXISTING N.T.S. EQUIPMENT NAMEPLATE E-D101 AHU-X 480V, 3Ø FED FROM "NDH1-4" AHU-X 480V, 3Ø FED FROM "NDH1-4" TYPICAL EQUIPMENT 116" THICK WHITE PLASTIC WITH COLORED FACE PER SPECIFICATIONS. 1 2" HIGH LETTERING FOR PANELBOARD NAME. 1 4" HIGH LETTERING FOR REMAINING TEXT. ADHESIVE BACKING WHEN INSTALLED IN CONDITIONED SPACES. EQUIPMENT NAME. EQUIPMENT VOLTAGE AND PHASE. EQUIPMENT SOURCE (PANEL & CIRCUIT) FASTEN WITH BRASS SCREWS WHEN LOCATED IN NON-CONDITIONED OR EXTERIOR SPACES 1" M I N . 2.5" MIN. E2 N.T.S. NAMEPLATE E-D102 PANEL "XXXX" 120/208V, 3Ø, 4W FED FROM PANEL "XXXX" VIA T-XXX PANEL "XXX" 277/408V, 3Ø, 4W FED FROM PANEL "XXXX" TYPICAL 120/208V PANELBOARD TYPICAL 120/208V PANELBOARD 1 2" HIGH LETTERING FOR PANELBOARD NAME 1 4" HIGH LETTERING FOR REMAINING TEXT 116" THICK WHITE PLASTIC WITH COLORED FACE PER SPECIFICATIONS PANELBOARD NAME PANELBOARD VOLTAGE PANELBOARD SOURCE 1" M I N . 2.5" MIN. PANELBOARDE3 54 " N.T.S. MOUNTING HEIGHT DETAIL E-D100 42" A.F.F. W/ 36" COUNTER, 39" A.F.F. W/ 30" COUNTER, 48" A.F.F. WITHOUT COUNTER OR AS NOTED ON PLANS. EXIT F 78 " M A X . TO T O P D E V I C E 36 " A F F PANELBOARD WALL MOUNTED LIGHT FIXTURES AS NOTED ON PLANS 6" A F C DUPLEX RECEPTACLE 1 1 ℄90 " CENTER BETWEEN DOOR AND CEILING (COORDINATE WITH ARCHITECT) ℄ CENTER OVER DOOR (WHERE APPLICABLE) ℄ 48 " FINISHED FLOOR ℄ SWITCH FA PULL STATION FIRE HORN (OR CHIME) & LIGHT 80" AFF FROM BOTTOM OF DEVICE. TELEVISION OUTLET CLOCK OUTLET 80 " ℄ VOLUME CONTROL REMOTE TEST TELEPHONE OUTLET COMPUTER OUTLET ℄ 18 " A F F ℄ SPECIAL POWER OUTLET TELEPHONE OUTLET DUPLEX RECEPTACLE E1 N.T.S. COVERPLATE E-D102 DEVICE PANEL-CIRCUIT PANEL-CIRCUIT 1 2" HIGH P-TOUCH LABEL, BLACK TEXT ON CLEAR BACKROUND COLOR RECEPTACLE COVER PLATE SWITCH COVER PLATE 1 4" HIGH LETTERING FOR PANEL NAME AND CIRCUIT NUMBER 1 4" HIGH LETTERING FOR PANEL NAME AND CIRCUIT NUMBER 12" HIGH P-TOUCH LABEL, BLACK TEXT ON CLEAR BACKROUND COLOR E4