Loading...
HomeMy WebLinkAbout2004 Notice of Receipt of ApplicationJeb Bush Governor Department of Environmental Protection Central District 3319 Maguire Boulevard, Suite 232 Orlando, Florida 32803-3767 July 20, 2004 Sent via a -mail: jmilewski@cityofsebastian.org CITY OF SEBASTIAN 1225 MAIN STREET SEBASTIAN FL 32958 ATTENTION JASON MILEWSKI CITY AIRPORT MANAGER Colleen Castille Secretary OCD -DW -04-0600 Indian River County - CS Sebastian Administration Building & Police Evidence Compound Dear Mr. Milewski: This is to acknowledge receipt of your application, plans and related material for the above project. Your application has been reviewed and the following items require your attention and response in accordance with Rules 62-4.055 and 62-4.070 and 62-604, Florida Administrative Code (F.A.C.): 1. Please revise the engineering drawing sheet to include a note on the minimum vertical and horizontal separation between potable water and sanitary sewer mains to comply with Rules 62-604.400(2)(g) — (i), F.A.C. and 62-604.400 (3), F.A.C., as noted below. New or relocated, underground water mains shall be laid to provide a horizontal distance of at least six feet, and preferably ten feet, between the outside of the water main and the outside of any existing or proposed gravity- or pressure-type sanitary sewer, wastewater force main, or pipeline conveying reclaimed water not regulated under Part III of Chapter 62-610, F.A.C. The minimum horizontal separation distance between water mains and gravity -type sanitary sewers shall be reduced to three feet where the bottom of the water main is laid at least six inches above the top of the sewer. New or relocated, underground water mains crossing any existing or proposed gravity- or vacuum -type sanitary sewer shall be laid so the outside of the water main is at least six inches, and preferably 12 inches, above or at least 12 inches below the outside of the other pipeline. However, it is preferable to lay the water main above the other pipeline. At the utility crossings described above, one full length of water main pipe shall be centered above or below the other pipeline so the water main joints will be as far as possible from the other pipeline. Alternatively, at such crossings, the pipes shall be arranged so that all water main joints are at least three feet from all joints in vacuum -type sanitary sewers, or pipelines conveying reclaimed water regulated under Part III of Chapter 62-610, F.A.C., and at least six feet from all joints in gravity- or pressure-type sanitary sewers, wastewater force mains, or pipelines conveying reclaimed water not regulated under Part III of Chapter 62-610, F.A.C. City of Sebastian OCD -DW -04-0600 Page 2 2. There appears to be a discrepancy between Part II, Subpart (5)(A)(26) of the permit application and sheets C5, C6 of 14 of the engineering plans. The item is initialed, however, the engineering plans show a design different from the standard criteria. Please provide a brief, but specific explanation why this item does not apply. 3. The operating conditions for the proposed lift station in the engineering drawings and the permit application do not correspond. Please revise to ensure all permit documentation is in concurrence. 4. It is recommended to install an isolation valve every 1000 LF of proposed force main constructed. 5. Please label the type of material for the proposed forcemain in the engineering plans and Part II item 2 in the permit application and resubmit. Construction of the proposed collection/transmission system without a valid permit issued by the Department is a violation of Section 403.087(1), Florida Statutes (F.S.) and subject to penalties under Section 403.161, F.S. You are requested to respond, in writing, to the above items within thirty (30) days of the date of this letter. Pursuant to Section 120.60, Florida Statutes, the Department may deny a permit application if the applicant, after receiving notice, fails to correct errors, omissions, or supply additional information within a reasonable period of time. The processing of this application will resume following receipt of the information requested above. Please refer to this letter in your response. Should you wish to discuss the above comments, please feel free to contact me or Tricia Williams at (407)893-3315. Sincerely, 0,,v;,,, E To -we lti, Arthur E. Torvela, P.E. Permitting Engineer Domestic Waste Section AET/cs cc: William F. Archebelle (via email: barchebelle@irgov.com) Bruce Moia, P.E. (via email: mosby001@yahoo.com)