Loading...
HomeMy WebLinkAbout2004 Energy Efficiency CodeENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 FORM 40OA-2001 Whole Building Performance Method for Commercial Buildings Jurisdiction: SEBASTIAN, INDIAN RIVER COUNTY, FL (411400) Short Desc: • 04120 Project: Sebastian Administration Building Owner: C.E. Block Address: City: Sebastian State: Florida Zip: 0 Type: Office (Business) Class: New Finished building PermitNo: 0 Storeys: 1 GrossArea: 8462 Net Area: 8462 Max Tonnage: 3 (if different, write in) Compliance Summary Component Design Criteria Result Gross Energy Use 60.25 100.00 PASSES Other Envelope Requirements - A PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES PASSES PASSES PASSES Yes/No/NA IMPORTANT NOTE. An input report Print -Out from EnergyGauge Fla Com of this design building must be submitted along with this Compliance Report. 8/19/2004 EnergyGauge FlaCom FLCCSB vl.22 1 COMPLIANCE CERTIFICATION: I hereby certify that the plans and Review of the plans and specifications covered by this specifications covered by this calculation are calculation indicates compliance with the Florida Energy in compliance with the Florida Energy Code. Before construction is completed, this building will be Efficiency Code. Inspected for compliance in accordance with Section 553.908, F.S. PREPARED BY: Jason Smith BUILDING OFFICIAL: DATE: 4 DATE: I hereby certiy that this building is in compliance with the Florida Energy Efficiency Code. OWNER AGENT- DATE: If required by Florida law, I hereby certify (') that the system design is in compliance with the Florida Energy Code. REGISTRATION No. ARCHITECT: ELECTRICAL SYSTEM DESIGNER: Tom Aitcheson PE FL#32166 LIGHTING SYSTEM DESIGNER: Tom Aitcheson MECHANICAL SYSTEM DESIGNER: Jason Smith PE FL#57743 PLUMBING SYSTEM DESIGNER: Jason Smith PE FL#57743 (') Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 Project: 04120 Title: Sebastian Administration Building Type: Office (Business) Location: SEBASTIAN, INDIAN RIVER COUNTY, FL (411400) (WEA File: D Whole Building Compliance Design Reference Total 60.25 100.00 ELECTRICITY 60.25 100.00 AREA LIGHTS 17.36 24.83 MISC EQUIPMT 7.42 L42 PUMPS & MISC 0.17 0.17 SPACE COOL 20.62 24.00 VENT FANS 14.68 43.58 Credits & Penalties (if any): Modified Points: = 60.26 PASSES 8/19/2004 Energy GaugeFlaCom FLCCSB v1.22 Project: 04120 Title: Sebastian Administration Building Type: Office (Business) Location: SEBASTIAN, INDIAN RIVER COUNTY, FL (411400) (WEA File: D Other Envelope Requirements Item Zone Description Design Limit Meet Req. Roof AHU-IA Exterior Roof - Max Uo Limit 0.03 0.09 Yes Roof AHU-IB Exterior Roof- Max Uo Limit 0.03 0.09 Yes Roof AHU-2 Exterior Roof- Max Uo Limit 0.03 0.09 Yes Roof AHU-6 Exterior Roof - Max Uo Limit 0.03 0.09 Yes Roof AHU-3A Exterior Roof - Max Uo Limit 0.03 0.09 Yes Roof AHU-3B Exterior Roof - Max Uo Limit 0.03 0.09 Yes Roof AHU4A Exterior Roof - Max Uo Limit 0.03 0.09 Yes Roof AHU4B Exterior Roof- Max Uo Limit 0.03 0.09 Yes Roof AHU-5 Exterior Roof - Max Uo Limit 0.03 0.09 Yes Meets Other Envelope Requirements External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (RI) (Sgft or ft) None 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 Project: 04120 Title: Sebastian Administration Building Type: Office (Business) Location: SEBASTIAN, INDIAN RIVER COUNTY, FL (411400) (WEA File: D Lighting Controls Compliance Acronym Ashrae Description ID Area No. of Design Min Compli- (sq.ft) Tasks CP CP ance 107,402406,Coni 32 Offices (Partitions<3.5 ft below 913 1 8 2 PASSES ceiling) Open plan offices 900 ft or larger with partitions higher Rms 407411 32 Offices (Partitions<3.5 ft below 627 1 5 2 PASSES ceiling) Open plan offices 900 ft or larger with partitions higher 108,501-504,Corri 32 Offices (Partitions<3.5 ft below 1,321 1 8 2 PASSES ceiling) Open plan offices 900 ft or larger with partitions higher Rms 506-510,E1ec 35 Common Activity Areas - 941 1 4 2 PASSES Conference/Meeting Room Rms 101, 201, 20 32 Offices (Partitions<3.5 ft below 1,104 1 4 2 PASSES ceiling) Open plan offices 900 ft or larger with partitions higher Rms 104,200,203 32 Offices (Partitions<3.5 ft below 1,268 1 9 2 PASSES ceiling) Open plan offices 900 ft or larger with partitions higher Rjns 300-304 32 Offices (Partitions<3.5 ft below 730 1 5 2 PASSES ceiling) Open plan offices 900 ft or larger with partitions higher Rens 305-308,Plt L 32 Offices (Partitions<3.5 ft below 552 1 5 2 PASSES ceiling) Open plan offices 900 ft or larger with partitions higher Rotunda 2 Corridor 1,006 1 4 2 PASSES PASSES 8/19/2004 EnergyGaugeFlaCom FLCCSB v1.22 Project: 04120 Title: Sebastian Administration Building Type: Office (Business) Location: SEBASTIAN, INDIAN RIVER COUNTY, FL (411400) (WEA File: D System Report Compliance AHU-1A Plan West- Rms 107,402-406 & Corridor Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System Air Cooled < 65000 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.20 0.80 PASSES System -Supply Constant Volume AHU-1B Plan West - Rms 407-411 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.20 0.80 PASSES System -Supply Constant Volume AMU -2 Plan South-Rms 108,501-504 & Corridor Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.30 0.80 PASSES System -Supply Constant Volume AHU-6 Plan South - Rms 506-510 & Elec Rin Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.30 0.80 PASSES System -Supply Constant Volume 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 AHU-3A Plan East - Rms 101, 201,202 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.30 0.80 PASSES System -Supply Constant Volume AHU-3B Plan East - Rms 104, 200, 203-209 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Au Cooled < 65000 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.30 0.80 PASSES System -Supply Constant Volume AHU4A Plan North - Rms 300-304 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.20 0.80 PASSES System -Supply Constant Volume AIIU-4B Plan North - Rms 305-308 & Pilots Constant Volume Air Cooled No. of Units Lounge Split System <65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.20 0.80 PASSES System -Supply Constant Volume AHU-5 Rotunda Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 2 Component Category Capacity Design Elf Design IPLV Comp- Eff Criteria IPLV Criteria liance 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 Cooling System Air Handling System -Supply Air Cooled < 65000 Btu/h 10.00 Cooling Capacity Air Handler (Supply) - 0.30 Constant Volume 10.00 8.00 PASSES 0.80 PASSES PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: 04120 Title: Sebastian Administration Building Type: Office (Business) Location: SEBASTIAN, INDIAN RIVER COUNTY, FL (411400) (WEA File: D Water Heater Compliance Description Type Category Design Eff Min Design Max Comp Eff Loss Loss liance EWH-1 Storage Water Heater- <=120 [gal] & <= 0.98 Electric 12 [M) 0.87 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 A: 04120 Sebastian Administration Building Office (Business) ion: SEBASTI Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R- 19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge F1aCom attached? 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 9 8/19/2004 EiierbVGauge FlaCom FLCCSB v1.22 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 INPUT DATA REPORT Project Information Project Name: 04120 Orientation: NorthEast Project Title: Sebastian Administration Building Building Type: Office (Business) Address: Building Classification: New Finished building State: Florida No.of Storeys: I Zip: 0 GrossArea: 5462 Owner: C.E. Block Zones No Acronym Description Type Load Profile Area Multiplier Total Area Istl Ist] 1 AHU-IA Plan West - Rms 107, 402-406 & Corridor 2 AHU-IB Plan West - Rms 407411 CONDITIONED Uses'Building Load 913.0 Profile CONDITIONED Uses Building Load 627.0 1 1 913.0 627.0 ❑ ❑ 3 AHU-2 Plan South - Rms 108, 501-504 & Corridor 4 AHU-6 Plan South - Rms 506-510 & Elec Rm Profile CONDITIONED Uses Building Load 1321.0 Profile CONDITIONED Uses Building Load 941.0 Profile 1 1 1321.0 941.0 ❑ ❑ 8/19/2004 EiierbVGauge FlaCom FLCCSB v1.22 5 AI�U-3A Plan East - Rms 101, 201, CONDITIONED Uses Building Load 1104.0 1 1104.0 202 Profile 6 AHU-3El B Plan East- Rms 104, 200, CONDITIONED Uses Building Load 1268.0 1 1268.0 203-209 Profile 7 AHU-4A Plan North - Rms 300-304 CONDITIONED Uses Building Load 730.0 1 730.0 0 Profile 8 AHU-4B Plan North - Rms 305-308 CONDITIONED Uses Building Load 552.0 1 552.0 & Pilots Lounge Profile 9 AHU-5 Rotunda CONDITIONED Uses Building Load 1006.0 1 1006.0 Profile Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] IN [ft] plier [sf] [cf] In Zone: AHU-IA 1 107,402406, Plan West - Rms107, Offices (Partitions<3.5 R 1.00 913.00 11.00 1 913.0 10043.0 402-406 & Corridor below ceiling) Open plan offices 900 ft or larger with partitions higher In Zone: AHU-1B 1 Rms 407-411 Plan West - Rms Offices (Partitions<3.5 ft 1.00 627.00 11.00 1 627.0 6897.0 407-411 below ceiling) Open plan offices 900 ft or larger with partitions higher In Zone: AHU-2 1- 108,501-504, Plan South - Rms 108, Offices (Partitions<3.5 ft 1.00 1321.00 11.00 1 1321.0 14531.0 501-504 & Corridor below ceiling) Open plan offices 900 ft or larger with partitions higher In Zone: AHU-6 1 Rms 506-510, Plan South - Rms Common Activity Areas - 1.00 941.00 11.00 1 941.0 10351.0 506-510 & Elec Rm Conference/Meeting Room In Zone: AHU-3A 1 Rms 101, 201,P1an East- Rms 101, Offices (Partitions<3.5 ft 1.00 1104.00 11.00 1 1104.0 12144.0 201,202 below ceiling) Open plan offices 900 ft or larger with partitions higher In Zone: AHU-3B 8/19/2004 EnergyGauge F1aCom FLCCSB v1,22 ast - Rms 104, Offices (Partitions<3.5 ft 1.00 1268.00 11.00 1 1268.0 13948.0 203-209 below ceiling) Open plan offices 900 ft or larger with FZone: partitions higher orth - Rms Offices (Partitions<3.5 ft 1.00 730.00 11.00 1 730.0 8030.0 04 below ceiling) Open plan offices 900 ft or larger with partitions higher In Zone: AHU-4B 1 Rms 305-308, Plan North - Rms Offices (Partitions<3.5 ft 1.00 552.00 11.00 1 552.0 6072.0 305-308 & Pilots below ceiling) Open plan Lounge offices 900 ft or larger with partitions higher In Zone: AHU-5 IL 1 Rotunda Rotunda Corridor 1.00 1006.00 11.00 1 1006.0 11066.0 Lighting No Type Power Control Type No.of [cy] Ctrl pts In Zone: AEW -IA In Space: 107,402-406,Corridor 1 Recessed Fluorescent - No vent 1104.00 Manual On/Off 6 El 2 Compact Fluorescent 278.00 Manual On/Off 2 In Zone; AHU-1B In Space: Rms 407-411 1 Recessed Fluorescent - No vent 1000.00 Manual On/Off 5 In Zone: AHU-2 In Space: 108,501-504,Corridor I Recessed Fluorescent - No vent 1706.00 Manual On/Off 6 ❑ 2 Compact Fluorescent 210.00 Manual On/Off 2 In Zone: AHU-6 In Space: Rms 506-510,Elec Rm 1 Recessed Fluorescent - No vent Lone: 1652.00 Manual On/Off 4 AHU-3A 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 s 101, 201, 202 Recessed Fluorescent - No vent 1436.00 Manual On/Off 4 B FFSpace: s 104,200,203-209 Recessed Fluorescent - No vent 1536.00 Manual On/Off 7 Compact Fluorescent 312.00 Manual On/Off 2 ❑ In Zone: AHU-4A In Space: Rms 300-304 1 Recessed Fluorescent - No vent 768.00 Manual On/Off 3 2 Compact Fluorescent 270.00 Manual On/Off 2 In Zone: AHU-4B In Space: Rms 305-308,P1t Lng 1 Recessed Fluorescent - No vent 836.00 Manual On/Off 5 In Zone: AHU-5 In Space: Rotunda 1 Compact Fluorescent 658.00 Manual On/Off 4 ❑ Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R -Value [ft] Ift) plier [st] [Btu/hr. sf. F) Capacity [lb/ct] [h.sf.FBtu] [Btu/sf.F] In Zone: AHU-1A 1 Plan West - Rms107, 5/8" stucco 3.00 11.00 1 33.0 NorthWes 0.2067 5.7314 34.65 4,84 (] 402-406 & Corridor /8"CMU/3/4"ISO t BTWN24"oc/.5" Gyp 2 Plan West - Rms107, 5/8" stucco 44.00 11.00 1 484.0 North 0.2067 5.7314 34.65 4.84 I] 402-406 & Corridor /8"CMU/3/4"ISO BT,fN24"oc/.5" Gyp 3 Plan West- Rms107, 5/8" stucco 3.00 11.00 1 33.0 East 0.2067 5.7314 34.65 4.84 0 402-406 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 4 Plan West- Rms 107, 5/8" stucco 220.0 402-406 & Corridor /8"CMU/3/4"ISO 5.7314 34.65 BTWN24"oc/.5" 12.00 Gyp 5 Plan West - Rms 107, 5/8" stucco 0.2067 402-406 & Corridor /8"CMU/3/4"ISO 4.84 BTWN24"oc/.5" Gyp 6 Plan West - Rms 107, 5/8" stucco 402-406 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5' Gyp 7 Plan West - Rms107, 5/8" stucco 402-406 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5' Gyp In Zone: AHU-1B I Plan West- Rots 5/8" stucco 407-411 /8"CMU/3/4"ISO BTWN24"or/.5" Gyp 2 Plan West - Rms 5/8" stucco 407-411 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 Plan West - Rms 5/8" stucco 407-411 /8"CMU/3/4"ISO BTWN24"oe/.5" Gyp In Zone: AHU-2 I Plan South - Rms 108, 5/8" stucco 501-504 & Corridor 18"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 Plan South - Rms 108, 5/8" stucco 501-504 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5' Gyp 3 Plan South - Rms 108, 5/8" stucco 501-504 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5' 20.00 11.00 1 220.0 North 0.2067 5.7314 34.65 4.84 12.00 11.00 1 132.0 West 0.2067 5.7314 34.65 4.84 3.00 11.00 1 33.0 South 0.2067 5.7314 34.65 4.84 oil 5.00 11.00 1 55.0 West 0.2067 5.7314 34.65 4.84 ❑ II 3.00 11.00 1 33.0 North 0.2067 5.7314 34.65 4.84 oil 12.00 11.00 1 132.0 West 0.2067 5.7314 34.65 4.84 E] II 58.00 11.00 1 638.0 South 0.2067 5.7314 34.65 4.84 ❑ II 3.00 11.00 1 33.0 South 0.2067 5.7314 34.65 4.84 ❑ II 13.00 11.00 1 143.0 SouthWes 0.2067 5.7314 34.65 4.84 t 21.00 11.00 1 231.0 West 0.2067 5.7314 34.65 4.84 oil 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 5 4 Plan South - Rms 108, 5/8" stucco 6.00 11.00 1 66.0 North 0.2067 5.7314 34.65 4.84 501-504 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 5 Plan South - Rms 108, 5/8" stucco 8.00 11.00 1 88.0 West 0.2067 5.7314 34.65 4.84 501-504 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 6 Plan South - Rms 108, 5/8" stucco 8.00 11.00 1 88.0 East 0.2067 5.7314 34.65 4.84 501-504 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 7 Plan South - Rms 108, 5/8" stucco 6.00 11.00 1 66.0 Nardi 0.2067 5.7314 34.65 4.84 E] 501-504 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 8 Plan South - Rms 108, 5/8" stucco 21.00 11.00 1 231.0 East 0.2067 5.7314 34.65 4.84 501-504 & Corridor /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: AHU-6 1 Plan South - Rms 5/8" stucco 9.00 11.00 1 99.0 West 0.2067 5.7314 34.65 4.84 506-510 & Elec Rm /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 Plan South - Rms 5/8" stucco 6.00 11.00 1 66.0 South 0.2067 5.7314 34.65 4.84 506-510 & Elea Rm /8"CMU/3/4"ISO BTWN24"ocL5" Gyp 3 Plan South - Rms 5/8" stucco 23.00 11.00 1 253.0 West 0.2067 5.7314 34.65 4.84 ❑ 506-510 & Elec Rm /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4 Plan South - Rms 5/8" stucco 30.00 11.00 1 330.0 South 0.2067 5.7314 34.65 4.84 E3 506-510 & Elec Rm 18"CMU/3/4"ISO BTWN24"oc/.5" Gyp 5 Plan South - Rms 5/8" stucco 23.00 11.00 1 253.0 East 0.2067 5.7314 34.65 4.84 506-510 & Elec Rm /8"CMU/3/4"ISO BTWN24"oe/.5" Gyp 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 6 atiyieuua EnergyGauge F1aCom FLCCSB v1.22 7 n South - Rms 5/8" stucco 6.00 11.00 1 66.0 South 0.2067 5.7314 34.65 4.84 -510 & Elec Rm /8"CMU/3/4"ISO BTWN24"oe/.5" F7PIan Gyp South - Rms 5/8" stucco 9.00 11.00 1 99.0 East 0.2067 5.7314 34.65 4.84 -510 & Elec Rm /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: AHU-3A 1 Plan East- Rms 101, 5/8" stucco 20.00 11.00 1 220.0 South 0.2067 5.7314 34.65 4.84 201,202 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 Plan East - Rms 101, 5/8" stucco 6.00 11.00 1 66.0 West 0.2067 5.7314 34.65 4.84 201,202 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 Plan East- Rms 101, 5/8" stucco 51.00 11.00 1 561.0 South 0.2067 5.7314 34.65 4.84 201,202 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4 Plan East - Rms 101, 5/8" stucco 17.00 11.00 1 187.0 East 0.2067 5.7314 34.65 4.84 201,202 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 5 Pian East - Rms 101, 5/8" stucco 3.00 11.00 1 33.0 North 0.2067 5.7314 34.65 4.84 201,202 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: AE1U-3B 1 Plan East - Rms 104, 5/8" stucco 5.00 11.00 1 55.0 East 0.2067 5.7314 34.65 4.84 ❑ 200, 203-209 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 Plan East - Rms 104, 5/8" stucco 3.00 11.00 1 33.0 South 0.2067 5.7314 34.65 4.84 ❑ 200, 203-209 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 Plan East - Rms 104, 5/8" stucco 11.00 11.00 1 121.0 East 0.2067 5.7314 34.65 4.84 ❑ 200, 203-209 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp atiyieuua EnergyGauge F1aCom FLCCSB v1.22 7 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 8 n East - Rms 104, 5/8" stucco 59.00 11.00 1 649.0 North 0.2067 5.7314 34.65 4.84 E 7200, 203-209 8"CMU/3/4"ISO BTWN24"oe/IS" Gyp 5 Plan East - Rms 104, 5/8" stucco 3.00 11.00 1 33.0 West 0.2067 5.7314 34.65 4.84 200, 203-209 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 6 Plan East - Rms 104, 5/8" stucco 16.00 11.00 1 176.0 North 0.2067 5.7314 34.65 4.84 200, 203-209 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 7 Plan East - Rins 104, 5/8" stucco 11.00 11.00 1 121.0 NorthEast 0.2067 5.7314 34.65 4.84 200, 203-209 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: AHU-4A 1 Plan North - Rms 5/8" stucco 16.00 11.00 1 176.0 East 0.2067 5.7314 34.65 4.84 E] 300-304 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 Plan North - Rms 5/8" stucco 3.00 11.00 1 33.0 South 0.2067 5.7314 34.65 4.84 300-304 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 Plan North - Rms 5/8" stucco 33.00 11.00 1 363.0 East 0.2067 5.7314 34.65 4.84 300-304 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4 Plan North - Rms 5/8" stucco 12.00 11.00 1 132.0 North 0.2067 5.7314 34.65 4.84 E] 300-304 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 5 Plan North - Rms 5/8" stucco 3.00 11.00 1 33.0 West 0.2067 5.7314 34.65 4.84 300-304 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 6 Plan North - Rms 5/8" stucco 5.00 11.00 1 55.0 North 0.2067 5.7314 34.65 4.84 300-304 /8"CMU/3/4"ISO 13TWN24"oc/.5" Gyp In Zone: AHU-4B 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 8 33.0 East 0.2067 5.7314 34.65 4.84 0 132.0 North 0.2067 5.7314 34.65 4.84 011 363.0 West 0.2067 5.7314 34.65 4.84 E] II 33.0 NorthWes 0.2067 5.7314 34.65 4.84 II t 77.0 SouthWes 0.2067 t 88.0 West 0.2067 33.0 NorthWes 0.2067 t 216.0 NorthWes 0.2067 t 312.0 SouthEast 0.2067 5.7314 34.65 4.84 011 5.7314 34.65 4.84 011 5.7314 34.65 4.84 E] 11 5.7314 34.65 4.84 [-] II 5.7314 34.65 4.84 [:] II 240.0 North 0.2067 5.7314 34.65 4.84 II 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 9 5/8" stucco 3.00 11.00 1 ots Lounge /8"CMCJ/3/4"ISO BTWN24"oc/.5" FPIanms Gyp ms 5/8" stucco 12.00 11.00 1 ots Lounge /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 Plan North - Rms 5/8" stucco 33.00 11.00 1 305-308 & Pilots Lounge /8"CMU/3/411ISO BTWN24"oc/.5" Gyp 4 Plan North - Rms 5/8" stucco 3.00 11.00 1 305-308 & Pilots Lounge /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 5 Plan North - Rms 5/8" stucco 7.00 11.00 1 305-308 & Pilots Lounge /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 6 Plan North - Rms 5/8" stucco 8.00 11.00 1 305-308 & Pilots Lounge /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 7 Plan North - Rms 5/8" stucco 3.00 11.00 1 305-308 & Pilots Lounge /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: AHU-5 I Rotunda 5/8" stucco 9.00 24.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 Rotunda 5/8" stucco 13.00 24.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 PrOZo9Wa3 5/8" stucco 10.00 24.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 33.0 East 0.2067 5.7314 34.65 4.84 0 132.0 North 0.2067 5.7314 34.65 4.84 011 363.0 West 0.2067 5.7314 34.65 4.84 E] II 33.0 NorthWes 0.2067 5.7314 34.65 4.84 II t 77.0 SouthWes 0.2067 t 88.0 West 0.2067 33.0 NorthWes 0.2067 t 216.0 NorthWes 0.2067 t 312.0 SouthEast 0.2067 5.7314 34.65 4.84 011 5.7314 34.65 4.84 011 5.7314 34.65 4.84 E] 11 5.7314 34.65 4.84 [-] II 5.7314 34.65 4.84 [:] II 240.0 North 0.2067 5.7314 34.65 4.84 II 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 9 ❑ ❑ ❑ ❑ ❑ ❑ ❑ It v It It 111�yyy E d It V W W N N N N N N N O O O O O O O 3 a ow o v, 3 z a F v v v v v v v N N N N N N N 3 N N N N N N N d O O O O O O O O O O O O O O to O- O- Q- Q- h h -Z UO Wh M4 (n Vl M [n h FY V]N 1--1 J O\ O p7 O� O O� O OO O O _ U QM C4 M U \ ;- U M_ � N U _M U M- i N W pq h 00 h \O h 0\O r ti a 4 y Q z d In Zone: AHU-lA 4.00 1 16.0 ED 4.00 5.00 In Wall: Wall 2 0 4.00 4.00 1 16.0 1 Plan West - DOUBLE CLEAR No 0.6514 0.88 0.81 Rms 107, 402-406 IG & Corridor In Wall: Wall 4 1 Plan West - DOUBLE CLEAR No 0.6514 0.88 0.81 Rms107,402-406 IG & Corridor In Wall: Wall 5 1 Plan West - DOUBLE CLEAR No 0.6514 0.88 0.81 Rms 107, 402-406 IG & Corridor In Zone: AHU-1B In Wall: Wall 3 1 Plan West - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 407-411 IG In Zone: AHU-2 In Wall: Wall 2 1 Plan South - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 108,501-504 & IG Corridor In Zone: AHU-3A In Wall: Wall 1 1 Plan East - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 101,201,202 IG In Wall: Wall 3 1 Plan East - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 101, 201, 202 IG In Zone: AHU-3B In Wall: Wall 3 1. Plan East - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 104,200,203-209 IG In Wall: Wall 4 1 Plan East - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 104, 200, 203-209 IG In Wall: Wall 6 1 PlanEast - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 104, 200,203-209 IG 4.00 4.00 3 48.0 01 4.00 5.00 2 40.0 0 4.00 4.00 1 16.0 E II 4.00 5.00 4 80.0 1111 4.00 5.00 2 40.0 El II 4.00 4.00 1 16.0 ED 4.00 5.00 2 40.0 0 4.00 4.00 1 16.0 ED 4.00 5.00 5 100.0 0 4.00 4.00 1 16.0 8/19/2004 EnergyGauge FlaCorn FLCCSB v1.22 11 AHU-4A 4.00 2 32.0 El 4.00 5.00 l: Wall 1 El 4.00 5.00 1 20.0 D 1 Plan North - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 FIn 300-304 IG ll: Wall3 1 Plan North - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 300-304 IG nWall: Wall 4 1 Plan North - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 300-304 IG In Zone: ABU -4B In Wall: Wall 2 1 Plan North - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 305-308 & Pilots IG Lounge In Wall: Wall 3 1 Plan North - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 305-308 & Pilots IG Lounge 4.00 4.00 2 32.0 El 4.00 5.00 2 40.0 El 4.00 5.00 1 20.0 D 4.00 5.00 1 20.0 F -I II 4.00 5.00 3 60.0 El II 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 12 In Zone: AHU-5 In Wall: Wall 10 I Rotunda DOUBLE CLEAR No 0.6514 0.88 0.81 8.00 7.00 1 56.0 El IG In Wall: Wall 3 1 Rotunda DOUBLE CLEAR No 0.6514 0.88 0.81 3.00 4.00 3 36.0 IG In Wall: Wall 4 1 Rotunda DOUBLE CLEAR No 0.6514 0.88 0.81 3.00 4.00 3 36.0 IG In Wall: Wall 5 1 Rotunda DOUBLE CLEAR No 0.6514 0.88 0.81 3.00 4.00 3 36.0 IG In Wall: Wall 6 1 Rotunda DOUBLE CLEAR No 0.6514 0.88 0.81 8.00 7.00 1 56.0 IG In Wall: Wall 7 I Rotunda DOUBLE CLEAR No 0.6514 0.88 0.81 3.00 4.00 3 36.0 IG In Wall: Wall 8 1 Rotunda DOUBLE CLEAR No 0.6514 0.88 0.81 3.00 4.00 3 36.0 El IG In Wall: Wall 9 1 Rotunda DOUBLE CLEAR No 0.6514 0.88 0.81 3.00 4.00 3 36.0 IG In Zone: AHU-6 In Wall: Wall 3 1 Plan South - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 4.00 5.00 1 20.0 506-510 & Elec IG Rm In Wall: Wall 4 1 Plan South - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 4.00 5.00 2 40.0 506-510 & Elec IG Rm In Wall: Wall 5 1 Plan South - Rms DOUBLE CLEAR No 0.6514 0.88 0.81 4;00 5.00 1 20.0 506-510 & Elec IG Rm 8/19/2004 EiiergyGauge F1aCom FLCCSB v1.22 13 F� Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.FBtu] In Zone: In Wall.- Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] IN plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: AHU-IA 1 Plan West- Md Bldg Roof/R-30 913.00 1.00 1 913.0 0.00 0.0330 3.81 13.35 30.30 ❑ Rms 107, 402-406 &Batt Corridor In Zone: AHU-1B 1 Plan West - Rms Mtl Bldg Roof/R-30 627.00 1.00 1 627.0 0.00 0.0330 3.81 13.35 30.30 ❑ 407-411 Batt In Zone: AEU-2 1 Plan South - Rms Mtl Bldg Roof/R-30 1321.00 1.00 1 1321.0 0.00 0.0330 3.81 13.35 30.30 ❑ 108,501-504 & Batt Corridor In Zone: ARU-6 1 Plan South - Rms Mtl Bldg Roof/R-30 941.00 1.00 1 941.0 0.00 0.0330 3.81 13.35 30.30 ❑ 506-510 & Elec Rm Batt In Zone: AHU-3A 1 Plan East - Rms 101,Mt1 Bldg Roof/R-30 1104.00 1.00 1 1104.0 0.00 0.0330 3.81 13.35 30.30 ❑ 201,202 Batt In Zone: AHU-3B 1 Plan East - Rms 104,Mtl Bldg Roof/R-30 1268.00 1.00 1 1268.0 0.00 0.0330 3.81 13.35 30.30 ❑ 200, 203-209 Batt In Zone: AHU-4A 1 Plan North - Rms Mtl Bldg Roof/R-30 730.00 1.00 1 730.0 0.00 0.0330 3.81 13.35 30.30 ❑ 300-304 Batt In Zone: AHU-4B 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 14 I Plan North - Rms Mtl Bldg Roof/R-30 552.00 1.00 1 552.0 0.00 0.0330 3.81 13.35 30.30 ❑ 305-308 & Pilots Batt Lounge In Zone: AHU-5 I Rotunda Md Bldg Roof/R-30 1006.00 1.00 1 1006.0 0.00 0.0330 3.81 13.35 30.30 ❑ Batt Skylights No Description Type UCen Shading Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] Coeff [ft[ [ft] [Sf] [Sf[ In Zone: In Roof: El Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. s£ F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: AHU-IA I Plan West - Concrete floor, 913.00 1.00 1 913.0 0.5987 9.33 140.00 1.67 ❑ Rms107, 402-406 & carpet and rubber Corridor pad In Zone: AHU-1B I Plan West-Rms Concrete floor, 627.00 1.00 1 627.0 0.5987 9.33 140.00 1.67 ❑ 407-411 carpet and rubber pad In Zone: AHU-2 1 Plan South - Rms Concrete floor, 1321.00 LOQ 1 1321.0 0.5987 9.33 140.00 1.67 ❑ 108,501-504 & carpet and rubber Corridor pad In Zone: AHU-6 1 Plan South - Rms Concrete floor, 941.00 1.00 1 941.0 0.5987 9.33 140.00 1.67 ❑ 506-510 & Elec Rm carpet and rubber pad In Zone: AHU-3A 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 15 I Plan East - Rms 101, Concrete floor, 1104.00 1.00 1 1104.0 0.5987 9.33 140.00 1.67 Q 201,202 carpet and rubber pad In Zone: AHU-3B I Plan East- Rms 104, Concrete floor, 1268.00 1.00 1 1268.0 0.5987 9.33 140.00 1.67 200, 203-209 carpet and rubber pad In Zone: AHU-4A 1 Plan North - Rms Concrete floor, 730.00 1.00 1 730.0 0.5987 9.33 140.00 1.67 0 300-304 carpet and rubber pad In Zone: AHU-4B 1 Plan North - Rms Concrete floor, 552.00 1.00 1 552.0 0.5987 9.33 140.00 1.67 EJ 305-308 & Pilots carpet and rubber Lounge pad In Zone: ARU -5 1 Rotunda Concrete floor, 1006.00 1.00 1 1006.0 0.5987 9.33 140.00 1.67 0 carpet and rubber pad Systems A13U-IA Plan West - Rms 107,402-406 & Constant Volume Air Cooled Split No. Of Units 1 Corridor System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 24500.00 10.00 8.00 Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 900.00 0.20 E:1 Constant Volume) ARU -1B Plan West - Rms 407-411 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 23700.00 10.00 8.00 E] Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 850.00 0.20 Constant Volume) 8/19/2004 EnergyGauge F1aCom FLCCSB vl.22 16 AHU-2 Plan South - Rms 108, 501-504 & Constant Volume Air Cooled Split No. Of Units 1 Corridor System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 38900.00 10.00 8.00 Capacity) 2 Air Handling System _Supply (Air Handler (Supply) - 1350.00 0.30 Constant Volume) ARU -6 Plan South - Rms 506-510 & Elec Rm Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 38500.00 10.00 8.00 Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 1400.00 0.30 E:1 Constant Volume) AHU-3A Plan East - Rms 101, 201, 202 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 31000.00 10.00 8.00 Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.30 Constant Volume) ARU -3B Plan East - Rms 104, 200, 203-209 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 35300.00 10.00 8.00 Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 1245.00 0.30 Constant Volume) 8/1912004 EnergyGauge F1aCom FLCCSB v1.22 17 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 18 North - Rms 300-304 ConstantVolume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 FAMHMU-4APlan tegoryCapacity Efficiency IPLV ing System (Air Cooled < 65000 Btu/h Cooling city) andling System -Supply (Air Handler (Supply) - tant Volume) 19000.00 10.00 8.00 800.00 0.20 AHU-4B Plan North - Rms 305-308 & Pilots Lounge Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 21300.00 10.00 8.00 800.00 0.20 El AHU-5 Rotunda Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 2 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) Au Handling System -Supply (Air Handler (Supply) - Constant Volume) 34000.00 10.00 8.00 1200.00 0.30 ID Plant Equipment Category Size Inst.No Eff. IPLV Li Water Heaters W -Heater Description Capacit Cap.Unit I/P Rt. Efficienc Loss 1 Storage Water Heater -Electric 50 Gal 9 [kW] 0.9800 [EF] [aMr] ❑ 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 18 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 19 Ext -Lighting Description Categories. Area/Len/No. of units [sf/ft/No] Wattage [W] Piping No 'Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Thickness [in] Is Runout? El Fenestration Used Name Glass Type No. of Panes Glass SC W T Conductance [Btu/h.sf.F] Frame Conductance [Btu/h.sf.F] Frame Absorptance ApLbWnd6 DOUBLE CLEAR IG 2 0.6514 0.8800 0.8120 0.4340 0.7000 ❑ Materials Used Mat No Acronym Description Only R -Value RValue Thickness Used [h.sf.F/Btu] [ft] Conductivity [Btu/h.ft.F] Density [lb/cf] SpecificHeat [Btu/1b.F] 18 264 214 187 Mat]18 Mat1264 Mat1214 Mat1187 2 in. Wood ALUMINUM, 1/16 IN POLYSTYRENE, EXP., 1-1/4IN, GYP OR PLAS BOARD,1/2IN No 2.3857 0.1670 No 0.0002 0.0050 No 5.2100 0.1042 No 0.4533 0.0417 0.0700 26.0000 0.0200 0.0920 37.00 480.00 1.80 50.00 0.3900 0.1000 0.2900 0.2000 ❑ ❑ ❑ ❑ 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 19 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 20 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 ❑ 20 F265 Matll51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,81NXOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 ❑ HW-UNDRD-140LB-41N 57 Mat157 3/4 in, Plaster or gypsum No 0.1488 0.0625 0.4200. 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3/4IN OR Yes 0.9000 ❑ LESS, VERT. WALLS 267 Matl267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 266 Mat1266 2x4@16"oc+RIIBatt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 2IN, 105 MatI105 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Matl256 WOOD, SOFT, 1-1/2IN No 1.8939 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0,625' stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Matl42 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 86 Mat186 BRICK, COMMON, 4IN No 0.8012 0.3333 0.4160 120.00 0.2000 ❑ 211 Mat1211 POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ N, 12 Matll2 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 218 Mat1218 POLYURETHANE,EXP.,1/2 No 3.2077 0.0417 0.0130 1.50 0.3800 ❑ IN, 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc + RI l Batt No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ 272 Mat1272 Panel with 7/16" panels Yes 0.9044 ❑ 273 Mat1273 Hollow core flush (1.375') Yes 1.2777 ❑ 274 Mat1274 Solid core flush (1.375') Yes 1.7141 ❑ 275 Mat1275 Panel with 7/16" panels Yes 1.0019 ❑ (1.375') 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 20 276 Mat1276 Hollow core flush (1.7511) Yes 1.3239 ❑ - 277 Mat1277 Panel with 1-1/8" panels Yes 1.7141 ❑ (1.75') 278 Mat1278 Solid core flush (1.75') Yes 1.6500 ❑ 279 Mat1279 Solid core flush (2.25') Yes 2.8537 ❑ 280 Mat1280 Fiberglass/Mineral wool core Yes 0.8167 ❑ 281 Mat1281 Paper Honeycomb core Yes 0.9357 ❑ 282 Mat1282 Solid Urethane foam core Yes 1.6500 ❑ 283 Mat1283 Solid mineral fiberboard core Yes 1.7816 ❑ 284 Matl284 Polystyrene core (18 ga steel) Yes 2.0071 ❑ 1 285 Mat1285 Polyurethane core (18 ga Yes 2.5983 ❑ steel) 2 286 Mat1286 Polyurethane core (24 ga Yes 2.5983 steel) 1 287 Mat1287 Polyurethane core (24 ga Yes 4.1500 ❑ steel) 2 288 Mat1288 Solid Urethane foam core Yes 4.1500 81 Mat181 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Mat1244 PLYWOOD, 1/2IN No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 185 Mat1185 CLAY TILE, PAVER, 3/81N No 0.0301 0.0313 1.0410 120.00 0.2000 ❑ 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 EJ SIDING I1 Matll l 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 47 Mat147 2 in. Heavyweight concrete No 0.1670 0.1670 1.0000 140.00 0.2000 ❑ 95 Matl95 CONC BLOCK No 0.7107 0.3333 0.4690 101.00 0.2000 ❑ HW -41N -HOLLOW 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAGI/2IN 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN Constructs Used 8/19/2004 EnergyGauge FlaCom FLCCSB v1.22 21 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 22 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1004 Concrete floor, cazpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.s£FBtu] 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8368 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625' stucco 0.0521 0.00 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.00 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.00 ❑ 4 187 GYP OR PLAS BOARD,1/2IN 0.0417 0,00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sf.F/Btu] 1048 Md Bldg Roof/R-30 Batt No No 0.03 3.81 13.35 30.3023 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.00 ❑ 2 18 2 in. Wood 0.1670 0.00 ❑ 3 72 AIR LAYER, 3/41N OR LESS, VERT. 0.00 ❑ WALLS 4 11 2 in. Insulation 0.1670 0.00 ❑ 5 23 6 in. Insulation 0.5000 0.00 ❑ 8/19/2004 EnergyGauge F1aCom FLCCSB v1.22 22 M N